Nhanganyaya
This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your PONTEC PondoCompact 500i fountain pump. Please read these instructions carefully before initial use and keep them for future reference. This product is designed for use in garden ponds and water features.
Mirayiridzo Yekuchengetedza
- Always disconnect the pump from the power supply before performing any maintenance or cleaning.
- Ita shuwa kuti kuiswa kwemagetsi kunoenderana nemitemo yemuno.
- Do not operate the pump if the power cable or housing is damaged.
- The pump is designed for water temperatures between +4°C and +35°C.
- Usashandise pombi iyi kune zvimwe zvinangwa kunze kweizvo zvakataurwa mubhuku rino.
- Keep children away from the pump and electrical connections.
Gadzirira
Follow these steps to set up your PondoCompact 500i fountain pump:
- Kuburitsa: Carefully remove the pump and all accessories from the packaging. Check for any damage.
- Kuiswa: Position the pump on a stable, level surface within your pond or water feature. The pump is designed for submersible use. Ensure it is fully submerged in water.
- Nozzle Attachment: Attach the desired fountain nozzle (not included, typically) to the pump's outlet. Ensure a secure fit to prevent leaks.
- Hose Connection (if applicable): If connecting to a filter or other water feature, attach the appropriate hose to the pump outlet. Secure with a hose clamp kana zvakakodzera.
- Power Connection: Once the pump is correctly positioned and submerged, connect the power plug to a properly installed and protected electrical outlet.

Image 1: The PONTEC PondoCompact 500i fountain pump, showing its compact design and suction cups for stable placement. This pump is designed for submersible operation in water features.
Operating Instruction
The PondoCompact 500i is designed for continuous operation. Once connected to power and fully submerged, the pump will begin to circulate water.
- Kutanga kwekutanga: After connecting to power, the pump will start immediately. Ensure the water level is sufficient to keep the pump fully submerged.
- Kugadzirisa Kuyerera: Some models may feature a flow control slider or knob. Adjust this to achieve the desired water flow rate for your fountain or water feature.
- Kuenderera Kushanda: The pump is designed for continuous use. Monitor water levels regularly to prevent dry running, which can damage the pump.

Mufananidzo 2: Kurutivi view of the PONTEC PondoCompact 500i pump, highlighting the water intake grille. This grille prevents larger debris from entering the pump mechanism.
Maintenance
Kugara kugadziridza kunovimbisa kuita kwakaringana uye kunowedzera hupenyu hwepombi yako.
- Bvisa Simba: Always unplug the pump from the power supply before any maintenance.
- Clean Intake Grille: Periodically remove the pump from the water and clean the intake grille to remove any accumulated debris, leaves, or algae. This prevents blockages and maintains flow.
- Kuchenesa Impeller: If flow significantly decreases, the impeller may be clogged.
- Remove the pump cover (refer to diagram if available, usually by unclipping or unscrewing).
- Carefully remove the impeller and clean it thoroughly with a soft brush and clean water.
- Inspect the impeller and its housing for any damage or wear.
- Reassemble the pump, ensuring all parts are correctly seated.
- Nguva Yechando Kuchengeta: During freezing temperatures, remove the pump from the pond. Clean it thoroughly and store it in a frost-free location, submerged in water if possible, or ensure it is completely dry to prevent damage.
Kugadzirisa matambudziko
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Pombi haina kutanga. | Hapana magetsi. Impeller yakajama. Motokari yakapisa. | Tarisa simba rekubatanidza uye fuse. Clean impeller and housing. Disconnect power, allow to cool, then restart. |
| Kuyerera kwemvura kwakaderedzwa. | Intake grille clogged. Impeller dirty. Hose/nozzle clogged. | Clean intake grille. Impeller yakachena. Clean hose and nozzle. |
| Pombi inoita ruzha rusingawanzoitiki. | Debris mune impeller. Dry running. | Impeller yakachena. Ensure pump is fully submerged. Check water level. |
Kana matambudziko akaramba aripo mushure mekutevera matanho aya, ndapota taura nerutsigiro rwevatengi.
Zvinotsanangurwa
- Muenzaniso: PondoCompact 500i
- Nhamba yeChinyorwa: 57503
- Max Flow Rate: 500 liters per hour (L/h)
- Cable Length: Refer to product packaging for exact cable length.
- Dimensions (approx.): Compact design, suitable for small fountains.
- Submersible: Ehe
Warranty
PONTEC products are manufactured to high-quality standards. This product comes with a manufacturer's warranty. Please refer to the warranty card included with your product or visit the official PONTEC webWebhusaiti kuti uwane mitemo nemirau yakadzama yewarandi. Chengeta humbowo hwekutenga kwako kuti uwane zvikumbiro zvewarandi.
Support
For technical assistance, spare parts, or further inquiries, please contact PONTEC customer support:
- Websaiti: www.pontec.com (Ndokumbirawo mutarise nzvimbo yenyu websaiti)
- Email/Phone: Refer to the contact information provided on the PONTEC websaiti kana mune yako chigadzirwa kurongedza.




