NJOY PWUP-OL300AP-AZ01B

NJOY Aten Pro 3000VA Uninterruptible Power Supply (UPS) User Manual

Model: PWUP-OL300AP-AZ01B

1. Nhanganyaya

The NJOY Aten Pro 3000VA Uninterruptible Power Supply (UPS) is designed to provide reliable power protection for sensitive electronic equipment. Featuring double conversion online technology and pure sine wave output, this UPS ensures continuous operation during power outages, voltage fluctuations, and spikes with zero transfer time. It is ideal for servers, data networks, and other critical systems requiring stable and clean power.

2. Mirayiridzo Yekuchengetedza

Please read and follow these safety instructions carefully before installing, operating, or maintaining the UPS. Failure to do so may result in injury or damage to the equipment.

  • Kuchengetedzwa Kwemagetsi: Connect the UPS to a grounded AC power outlet. Do not remove the grounding prong.
  • Indoor Use Chete: This UPS is intended for indoor use in a controlled environment. Avoid exposure to direct sunlight, heat sources, moisture, or corrosive substances.
  • Kufefetedza Iva nechokwadi chekuti mhepo inofema yakakwana yakatenderedza UPS. Usavhare maburi emhepo.
  • Kuchengetedzwa kweBhatiri: Batteries contain hazardous energy. Do not open or mutilate batteries. Battery servicing should be performed or supervised by personnel knowledgeable about batteries and the required precautions.
  • Overload Protection: Do not overload the UPS. Ensure the total power consumption of connected devices does not exceed the UPS's rated capacity.
  • Emergency Shutdown: Familiarize yourself with the location of the ON/OFF button for emergency shutdown.

3. Chigadzirwa Pamusoroview

The NJOY Aten Pro 3000VA UPS features a robust design with an intuitive LCD display and essential connectivity ports.

Mberi view of the NJOY Aten Pro 3000VA UPS with LCD display and control buttons.

Mufananidzo 3.1: Mberi view of the NJOY Aten Pro 3000VA UPS, showing the LCD screen and control panel.

Rear view of the NJOY Aten Pro 3000VA UPS, highlighting RS232, USB, SNMP slot, Schuko outlets, circuit breaker, and AC input.

Mufananidzo 3.2: Rear panel of the NJOY Aten Pro 3000VA UPS, detailing the various connection ports and outlets.

3.1. Rear Panel Components

  1. RS232 Interface: For serial communication with a computer or network device.
  2. Schuko Outlets (x4): Power output sockets for connecting protected equipment.
  3. Circuit Remake: Overload protection for the UPS.
  4. SNMP Slot: Optional slot for an SNMP card for network management.
  5. USB Interface: For USB communication with a computer.
  6. AC Input: Power input connection for the UPS.

4. Kuiswa uye Setup

4.1. Kusunungura

Carefully unpack the UPS and inspect it for any shipping damage. Retain the original packaging for future use or transport.

4.2. Kugadzwa

Place the UPS in a clean, dry, and well-ventilated area. Ensure sufficient clearance around the unit for proper airflow. Avoid placing it near heat sources or in direct sunlight.

4.3. Kubatanidza kuSimba

  1. Connect the UPS to a grounded AC power outlet using the provided power cord.
  2. Allow the UPS to charge for at least 4 hours before initial use to ensure optimal battery performance.

4.4. Connecting Equipment

Connect your critical electronic devices (e.g., computers, monitors, servers) to the Schuko output outlets on the rear panel of the UPS.

5. Kushanda

5.1. Kuvhura / Kudzima

  • Kubatidza: Press and hold the ON/MUTE button until you hear a beep. The UPS will perform a self-test and then enter AC mode.
  • Kudzima: Press and hold the OFF/ENTER button until the UPS shuts down.

5.2. LCD Ratidza

The LCD display provides real-time status information about the UPS, including:

  • Load Level
  • Battery Level
  • AC Mode
  • Battery Mode
  • Bypass Mode
  • Mhosva Indicators

5.3. Eco Mode

The Eco Mode feature helps reduce energy consumption. When the input voltage is within the acceptable range, the UPS will bypass the inverter to save energy, increasing overall efficiency.

6. Software Management

The NJOY Aten Pro 3000VA UPS includes management software for comprehensive monitoring and control. This software can be accessed via serial (RS232), USB, or an optional Ethernet (SNMP card) connection.

Screenshot of the UPS management software interface, showing system status, power flow, and configuration options.

Mufananidzo 6.1: Example of the UPS management software interface.

Key features of the management software include:

  • Real-time operational status visualization.
  • Scheduling for power on/off and battery tests.
  • Comprehensive UPS configuration options.
  • Safe shutdown of the operating system.

7. Kuchengeta

7.1. Battery Maintenance

The UPS uses sealed, maintenance-free lead-acid batteries. While these batteries do not require liquid top-ups, regular checks are recommended:

  • Perform a battery self-test periodically using the management software or UPS controls.
  • Replace batteries when their capacity significantly diminishes. Battery replacement should be performed by qualified personnel.

7.2. General Cleaning

Keep the UPS clean and free from dust. Use a dry cloth to wipe the exterior. Do not use liquid cleaners or solvents.

8. Kugadzirisa matambudziko

This section addresses common issues you might encounter with your NJOY Aten Pro 3000VA UPS.

DambudzikoZvinogona KukonzeraSolution
UPS does not turn onNo AC input power; Battery dischargedCheck power cord connection and wall outlet; Allow UPS to charge for several hours.
UPS beeps continuouslyOverload; Battery low/faultReduce connected load; Check battery status via LCD or software.
Short backup timeBattery not fully charged; Battery end-of-lifeCharge UPS for at least 4 hours; Consider battery replacement.
UPS in Bypass modeInternal fault; OverloadContact technical support if fault persists; Reduce connected load.

9. Zvinotsanangurwa

Detailed technical specifications for the NJOY Aten Pro 3000VA UPS.

FeatureTsanangudzo
BrandNJOY
Model NumberPWUP-OL300AP-AZ01B
Power Rating3000 VA / 2700 W
UPS TypeKushandurwa Kaviri Pamhepo
Output WaveformYakachena Sine Wave
Zita Rokuisa Voltage230 Zororo
Zita Rekuburitsa Voltage200, 208, 220, 230, 240 Vac
Accepted Input Voltage Range110-300 VAC ± 5% (50% load), 160-300 VAC ± 5% (100% load)
Frequency50 Hz ~ 60 Hz
Output Sockets4 x Schuko
Transfer Time (AC-DC)Zero
Kutamisa Nguva (Inverter kuBypass)4 ms
Communication PortsUSB, RS232 (Optional: Smart SNMP card)
Operating Temperature0 ~ 40 °C
KubudiriraKusvika 90%
Bhatiri TypeSealed Lead-Acid (Maintenance-Free)
Battery Configuration6 x 12V/9Ah
Inowirirana DevicesDVR, surveillance systems, Wi-Fi modem, monitor, printer, TV, desktop, gaming computer
Item Weight27.6 makirogiramu
Fomu FactorTower

10. Warranty uye Tsigiro

NJOY offers a comprehensive warranty and dedicated customer support for the Aten Pro series.

  • Warranty: The NJOY Aten Pro UPS comes with a 3-year warranty. Batteries are covered by a 1-year warranty.
  • Tsigiro yeVatengi: For assistance before, during, or after your purchase, please contact our professional customer service team.