RENOGY RNG-DCC1212-60-JP

Renogy DC-DC 12V 60A Battery Charger Instruction Manual

Model: RNG-DCC1212-60-JP

1. Safety Information

Ndapota verengai mirairo yese nenyevero dziri mubhuku rino nokungwarira musati maisa uye maishandisa. Kukundikana kutevedzera mirairo iyi kunogona kukonzera kuvhunduka kwemagetsi, moto, kana kukuvara kwakanyanya. Chengetai bhuku iri kuti muzoshandisa mune ramangwana.

  • Always wear appropriate personal protective equipment, including eye protection, when working with batteries and electrical systems.
  • Ensure all connections are tight and secure to prevent loose connections that can cause excessive heat and damage.
  • Do not operate the charger in wet or damp mamiriro.
  • Iva nechokwadi chekuti mhepo inofefetera zvakanaka yakatenderedza charger kudzivirira kupisa zvakanyanya.
  • Disconnect all power sources before performing any maintenance or troubleshooting.
  • Do not attempt to disassemble or repair the charger yourself. Contact qualified service personnel.

2. Chigadzirwa Pamusoroview

2.1 Mamiriro Akakosha

  • Yakasiyana-siyana Battery Kuenderana: The Renogy DC-DC charger is compatible with multiple alternator types and sub-battery types, including AGM, flooded, gel, and lithium-ion batteries.
  • Smart 3-Stage Kuchaja: This battery charger charges the sub-battery from the starter battery using a 3-stage charging process (bulk, boost, float), ensuring optimal and automatic 100% charge.
  • Main Battery Over-Discharge Protection: The DC-DC battery charger identifies whether the generator is running, preventing over-discharge of the starter battery and protecting the main battery.
  • Kuchengetedzwa Kwakawedzerwa: Provides over-voltage protection, over-temperature protection, and reverse polarity protection, ensuring safe operation. It also isolates input and output to prevent voltage transmission errors and protect the house battery from overcharging.
  • Durable Design: Features a compact and robust construction for reliable performance.

2.2 Zviyero zveChigadzirwa

Renogy DC-DC Charger with dimensions: 31.1 cm length, 17.5 cm width, 6.8 cm height

The image above shows the Renogy DC-DC Charger with its dimensions: 31.1 cm length, 17.5 cm width, and 6.8 cm height.

2.3 Zvikamu Tsanangudzo

Diagram of Renogy DC-DC Charger ports and indicators

This diagram illustrates the various ports and indicators on the Renogy DC-DC Charger.

#MarkTsanangudzo
1Nyora (+)Main Battery Positive
2Input (-)Main Battery Negative
3Power IndicatorPower chakarurama akatungamirira
4Error IndicatorError Indicator LED
5S1 S2 S3 S4 S5Battery Type Setting Switch (DIP Switches)
6RJ11Temperature Sensor Connection Port
7D+Signal Line Connection Port
8LCCurrent Limit Port
9Kubuda (+)Sub-battery Positive
10Kubuda (-)Sub-battery Negative

3. Setup uye Kuiswa

3.1 Dhizaini yekubatanidza

Wiring diagram for Renogy DC-DC Charger connecting to main and sub-batteries in an RV

This diagram illustrates the wiring connections for the DC-DC Charger in a typical RV setup, connecting to both the main (starter) battery and the sub-battery (house battery).

  • DC-DC Charger ↔ Main Battery Wiring
  • DC-DC Charger ↔ Sub-battery Wiring
  • DC-DC Charger D+ Port ↔ Alternator D+ Terminal Wiring

Cherechedza: All wiring requires separate purchase. Cables are not included with this product; please prepare them separately if needed.

3.2 DIP Switch Settings

DIP switch settings for Renogy DC-DC Charger to adjust battery type and charging voltage

The image shows the DIP switches used to configure the charger. By operating the 5 switches (S1-S5), you can adjust the battery type and charging voltage.

  • S1 and S2: Set Absorption Voltage
  • S3 and S4: Set Float Charge Voltage
  • S5: Set Charging Mode

3.3 Cable Saizi Sarudzo

Table showing recommended cable sizes and fuse ratings for different DC-DC charger models

Refer to this table for recommended cable sizes and fuse ratings based on your specific DC-DC charger model and cable length.

ModelCableMinimum Cable SizeFuse
DCC-1212-20Main Battery0.61m 5.5sq2.44m 5.5sq4.88m 8.0sq9.75m 22sq30A
Sub-bhatiri0.61m 3.5sq2.44m 3.5sq4.88m 5.5sq9.75m 14sq25A
DCC-1212-40Main Battery0.61m 14sq2.44m 14sq4.88m 22sq9.75m 38sq60A
Sub-bhatiri0.61m 8.0sq2.44m 8.0sq4.88m 14sq9.75m 22sq50A
DCC-1212-60Main Battery0.61m 22sq2.44m 22sq--90A
Sub-bhatiri0.61m 14sq2.44m 14sq4.8m 22sq-75A
D+/LC0.75~1.2SQ

3.4 D+ and LC Ports

Close-up of D+ and LC ports on Renogy DC-DC Charger

The image highlights the D+ and LC ports on the charger.

  • D+ Port: Connects to the alternator's D+ terminal for smart alternator detection.
  • LC Port: By connecting to the LC port, the charging current can be limited by half. (Recommended cable size: 0.75~1.2SQ)

4. Kushanda

4.1 3-Stage Kuchaja Maitiro

Girafu rinoratidza 3-stage charging process: Bulk, Absorption, and Float

The graph above illustrates the 3-stage charging process (Bulk, Absorption, Float) that fully charges the battery.

  • Kuwanda: Charges the battery at the maximum current until it reaches a set voltage.
  • Kunyura: Charges at a constant voltage, reducing current as the battery approaches full charge.
  • Float: Maintains the battery at a constant, lower voltage to prevent self-discharge.

4.2 LED zviratidzo

The charger features LED indicators to communicate the charging status and battery type. Refer to the tables below for detailed explanations.

Bhatiri Rudzi Chiratidziro
ColorStatusTsanangudzo
GirinhiONSLA (Zvakasarudzika)
YeroONGEL
TsvukuONFLD (Yakafashamirwa)
BhuruuONLI (Lithium)
ChenaONUser (Requires BT-2 Module and Renogy DC Home App)
Sevhisi Bhatiri Chiratidziro
ColorStatusTsanangudzo
GirinhiONBhatiri Yakazara
YeroONBhatiri voltage normal
TsvukuONBattery undervoltage
TsvukuSlow FlashingBhatiri rapera
TsvukuFast FlashingBhatiri pamusoro pevoltage/pamusoro tembiricha

Cherechedza: Chidziro Chekuchaja chinogona kuchinja pasi pemamiriro ezvinhu anotevera:

  1. Tsvuku kusvika Yero: Kana iro voltage inosvika 12.2V pasi pevoltage kupora.
  2. Yero kune Tsvuku: Kana iro voltage inodonha kusvika ku12.0V pasi pevoltage yambiro.
  3. Yero kusvika kuGreen: A. Kana yasvika voltage charging state, iyo yekuchaja ikozvino idiki pane 3A, inotora 30 masekonzi; B. Kana chaji ichi chakakwira kudarika 3A, inoramba ichichaja kudzamara yasvika pa vol.tage state uye madonhwe azvino ari pazasi 3A, anotora masekonzi makumi matatu.
Alternator / Yekuchaja Chiratidziro
ColorStatusTsanangudzo
GirinhiONAlternator iri kuchaja bhatiri rebasa
TsvukuSlow FlashingPV iri kuchaja iyo yekutanga bhatiri
DZIMAKwete kubhadharisa

4.3 Alternator Type and Starting Battery Voltage

Alternator TypeStarting Battery Voltage
Cheka-mukatiCheka
Traditional Alternator>13.2V, for 15 seconds<12.7V
Smart Alternator>12.0V, for 15 seconds<11.5V

4.4 Charging Current Distribution (Solar + Alternator)

ModelRBC30DISRBC50DIS
Chete Solar30A50A
Only Alt30A50A
Solar + ALT15A + 15A25A + 25A

When using both solar and alternator inputs, the current is split. For example, the RBC30DIS model will provide 15A from solar and 15A from the alternator, totaling 30A.

5. Kuchengeta

Regular maintenance ensures optimal performance and longevity of your Renogy DC-DC Charger.

  • Periodically check all wiring connections for tightness and corrosion. Clean any corroded terminals.
  • Inspect the charger for any physical damage or signs of overheating.
  • Ensure the area around the charger is free from dust and debris to maintain proper ventilation.
  • Verify that the battery type settings are correct for your installed batteries.

6. Kugadzirisa matambudziko

If you encounter issues with your DC-DC Charger, refer to the following basic troubleshooting steps:

  • Hapana Magetsi/Ma LED Akadzimwa: Check all battery connections and fuses. Ensure the starter battery voltage is above the cut-in threshold.
  • Error Indicator On: Refer to the LED Indicators section (4.2) for the specific error type (over-voltage, over-temperature, reverse polarity, etc.) and take corrective action.
  • Bhatiri risingachaji: Verify that the correct battery type is selected using the DIP switches. Check solar panel connections and output, and ensure the alternator is functioning correctly.
  • Reduced Charging Current: Ensure the LC port is not connected if full current is desired. Check cable sizes against recommendations in section 3.3.

For persistent issues, please contact Renogy customer support.

7. Zvinotsanangurwa

TsanangudzoValue
BrandRENOGU
ColorNhema
Zviyero zveChigadzirwa (D x W x H)17.5 x 31.1 x 6.8 cm
Kubuditsa Voltage12 Volts
Kutevedzera MitemoCE, RoHS
Rated Current60 Amps
Mugadziri Model NumberRNG-DCC1212-60-JP
GTIN (Nhamba Yekuzivikanwa Kwekutengeserana Kwepasi Pose)00810009715924
UPC810009715924
Product TypeDC-DC Charger
Inosanganisirwa ZvikamuJapanese Instruction Manual, DC-DC Charger Unit

8. Official Product Video

This video provides a visual guide on how to install and connect the Renogy DC-DC MPPT Charger, demonstrating connections to a starter battery, a lithium house battery, and a solar panel. It also covers setting battery types and understanding LED indicators for charging status.

9. Warranty uye Tsigiro

Ichi chigadzirwa chinouya ne 1-year mugadziri waranti.

For any questions or support regarding your Renogy DC-DC Charger, please contact our customer service team:

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.