1. Safety Information
Ndapota verengai mirairo yese nenyevero dziri mubhuku rino nokungwarira musati maisa uye maishandisa. Kukundikana kutevedzera mirairo iyi kunogona kukonzera kuvhunduka kwemagetsi, moto, kana kukuvara kwakanyanya. Chengetai bhuku iri kuti muzoshandisa mune ramangwana.
- Always wear appropriate personal protective equipment, including eye protection, when working with batteries and electrical systems.
- Ensure all connections are tight and secure to prevent loose connections that can cause excessive heat and damage.
- Do not operate the charger in wet or damp mamiriro.
- Iva nechokwadi chekuti mhepo inofefetera zvakanaka yakatenderedza charger kudzivirira kupisa zvakanyanya.
- Disconnect all power sources before performing any maintenance or troubleshooting.
- Do not attempt to disassemble or repair the charger yourself. Contact qualified service personnel.
2. Chigadzirwa Pamusoroview
2.1 Mamiriro Akakosha
- Yakasiyana-siyana Battery Kuenderana: The Renogy DC-DC charger is compatible with multiple alternator types and sub-battery types, including AGM, flooded, gel, and lithium-ion batteries.
- Smart 3-Stage Kuchaja: This battery charger charges the sub-battery from the starter battery using a 3-stage charging process (bulk, boost, float), ensuring optimal and automatic 100% charge.
- Main Battery Over-Discharge Protection: The DC-DC battery charger identifies whether the generator is running, preventing over-discharge of the starter battery and protecting the main battery.
- Kuchengetedzwa Kwakawedzerwa: Provides over-voltage protection, over-temperature protection, and reverse polarity protection, ensuring safe operation. It also isolates input and output to prevent voltage transmission errors and protect the house battery from overcharging.
- Durable Design: Features a compact and robust construction for reliable performance.
2.2 Zviyero zveChigadzirwa

The image above shows the Renogy DC-DC Charger with its dimensions: 31.1 cm length, 17.5 cm width, and 6.8 cm height.
2.3 Zvikamu Tsanangudzo

This diagram illustrates the various ports and indicators on the Renogy DC-DC Charger.
| # | Mark | Tsanangudzo |
|---|---|---|
| 1 | Nyora (+) | Main Battery Positive |
| 2 | Input (-) | Main Battery Negative |
| 3 | Power Indicator | Power chakarurama akatungamirira |
| 4 | Error Indicator | Error Indicator LED |
| 5 | S1 S2 S3 S4 S5 | Battery Type Setting Switch (DIP Switches) |
| 6 | RJ11 | Temperature Sensor Connection Port |
| 7 | D+ | Signal Line Connection Port |
| 8 | LC | Current Limit Port |
| 9 | Kubuda (+) | Sub-battery Positive |
| 10 | Kubuda (-) | Sub-battery Negative |
3. Setup uye Kuiswa
3.1 Dhizaini yekubatanidza

This diagram illustrates the wiring connections for the DC-DC Charger in a typical RV setup, connecting to both the main (starter) battery and the sub-battery (house battery).
- DC-DC Charger ↔ Main Battery Wiring
- DC-DC Charger ↔ Sub-battery Wiring
- DC-DC Charger D+ Port ↔ Alternator D+ Terminal Wiring
Cherechedza: All wiring requires separate purchase. Cables are not included with this product; please prepare them separately if needed.
3.2 DIP Switch Settings

The image shows the DIP switches used to configure the charger. By operating the 5 switches (S1-S5), you can adjust the battery type and charging voltage.
- S1 and S2: Set Absorption Voltage
- S3 and S4: Set Float Charge Voltage
- S5: Set Charging Mode
3.3 Cable Saizi Sarudzo

Refer to this table for recommended cable sizes and fuse ratings based on your specific DC-DC charger model and cable length.
| Model | Cable | Minimum Cable Size | Fuse | |||
|---|---|---|---|---|---|---|
| DCC-1212-20 | Main Battery | 0.61m 5.5sq | 2.44m 5.5sq | 4.88m 8.0sq | 9.75m 22sq | 30A |
| Sub-bhatiri | 0.61m 3.5sq | 2.44m 3.5sq | 4.88m 5.5sq | 9.75m 14sq | 25A | |
| DCC-1212-40 | Main Battery | 0.61m 14sq | 2.44m 14sq | 4.88m 22sq | 9.75m 38sq | 60A |
| Sub-bhatiri | 0.61m 8.0sq | 2.44m 8.0sq | 4.88m 14sq | 9.75m 22sq | 50A | |
| DCC-1212-60 | Main Battery | 0.61m 22sq | 2.44m 22sq | - | - | 90A |
| Sub-bhatiri | 0.61m 14sq | 2.44m 14sq | 4.8m 22sq | - | 75A | |
| D+/LC | 0.75~1.2SQ | |||||
3.4 D+ and LC Ports

The image highlights the D+ and LC ports on the charger.
- D+ Port: Connects to the alternator's D+ terminal for smart alternator detection.
- LC Port: By connecting to the LC port, the charging current can be limited by half. (Recommended cable size: 0.75~1.2SQ)
4. Kushanda
4.1 3-Stage Kuchaja Maitiro

The graph above illustrates the 3-stage charging process (Bulk, Absorption, Float) that fully charges the battery.
- Kuwanda: Charges the battery at the maximum current until it reaches a set voltage.
- Kunyura: Charges at a constant voltage, reducing current as the battery approaches full charge.
- Float: Maintains the battery at a constant, lower voltage to prevent self-discharge.
4.2 LED zviratidzo
The charger features LED indicators to communicate the charging status and battery type. Refer to the tables below for detailed explanations.
| Bhatiri Rudzi Chiratidziro | ||
|---|---|---|
| Color | Status | Tsanangudzo |
| Girinhi | ON | SLA (Zvakasarudzika) |
| Yero | ON | GEL |
| Tsvuku | ON | FLD (Yakafashamirwa) |
| Bhuruu | ON | LI (Lithium) |
| Chena | ON | User (Requires BT-2 Module and Renogy DC Home App) |
| Sevhisi Bhatiri Chiratidziro | ||
|---|---|---|
| Color | Status | Tsanangudzo |
| Girinhi | ON | Bhatiri Yakazara |
| Yero | ON | Bhatiri voltage normal |
| Tsvuku | ON | Battery undervoltage |
| Tsvuku | Slow Flashing | Bhatiri rapera |
| Tsvuku | Fast Flashing | Bhatiri pamusoro pevoltage/pamusoro tembiricha |
Cherechedza: Chidziro Chekuchaja chinogona kuchinja pasi pemamiriro ezvinhu anotevera:
- Tsvuku kusvika Yero: Kana iro voltage inosvika 12.2V pasi pevoltage kupora.
- Yero kune Tsvuku: Kana iro voltage inodonha kusvika ku12.0V pasi pevoltage yambiro.
- Yero kusvika kuGreen: A. Kana yasvika voltage charging state, iyo yekuchaja ikozvino idiki pane 3A, inotora 30 masekonzi; B. Kana chaji ichi chakakwira kudarika 3A, inoramba ichichaja kudzamara yasvika pa vol.tage state uye madonhwe azvino ari pazasi 3A, anotora masekonzi makumi matatu.
| Alternator / Yekuchaja Chiratidziro | ||
|---|---|---|
| Color | Status | Tsanangudzo |
| Girinhi | ON | Alternator iri kuchaja bhatiri rebasa |
| Tsvuku | Slow Flashing | PV iri kuchaja iyo yekutanga bhatiri |
| DZIMA | Kwete kubhadharisa | |
4.3 Alternator Type and Starting Battery Voltage
| Alternator Type | Starting Battery Voltage | |
|---|---|---|
| Cheka-mukati | Cheka | |
| Traditional Alternator | >13.2V, for 15 seconds | <12.7V |
| Smart Alternator | >12.0V, for 15 seconds | <11.5V |
4.4 Charging Current Distribution (Solar + Alternator)
| Model | RBC30DIS | RBC50DIS |
|---|---|---|
| Chete Solar | 30A | 50A |
| Only Alt | 30A | 50A |
| Solar + ALT | 15A + 15A | 25A + 25A |
When using both solar and alternator inputs, the current is split. For example, the RBC30DIS model will provide 15A from solar and 15A from the alternator, totaling 30A.
5. Kuchengeta
Regular maintenance ensures optimal performance and longevity of your Renogy DC-DC Charger.
- Periodically check all wiring connections for tightness and corrosion. Clean any corroded terminals.
- Inspect the charger for any physical damage or signs of overheating.
- Ensure the area around the charger is free from dust and debris to maintain proper ventilation.
- Verify that the battery type settings are correct for your installed batteries.
6. Kugadzirisa matambudziko
If you encounter issues with your DC-DC Charger, refer to the following basic troubleshooting steps:
- Hapana Magetsi/Ma LED Akadzimwa: Check all battery connections and fuses. Ensure the starter battery voltage is above the cut-in threshold.
- Error Indicator On: Refer to the LED Indicators section (4.2) for the specific error type (over-voltage, over-temperature, reverse polarity, etc.) and take corrective action.
- Bhatiri risingachaji: Verify that the correct battery type is selected using the DIP switches. Check solar panel connections and output, and ensure the alternator is functioning correctly.
- Reduced Charging Current: Ensure the LC port is not connected if full current is desired. Check cable sizes against recommendations in section 3.3.
For persistent issues, please contact Renogy customer support.
7. Zvinotsanangurwa
| Tsanangudzo | Value |
|---|---|
| Brand | RENOGU |
| Color | Nhema |
| Zviyero zveChigadzirwa (D x W x H) | 17.5 x 31.1 x 6.8 cm |
| Kubuditsa Voltage | 12 Volts |
| Kutevedzera Mitemo | CE, RoHS |
| Rated Current | 60 Amps |
| Mugadziri Model Number | RNG-DCC1212-60-JP |
| GTIN (Nhamba Yekuzivikanwa Kwekutengeserana Kwepasi Pose) | 00810009715924 |
| UPC | 810009715924 |
| Product Type | DC-DC Charger |
| Inosanganisirwa Zvikamu | Japanese Instruction Manual, DC-DC Charger Unit |
8. Official Product Video
This video provides a visual guide on how to install and connect the Renogy DC-DC MPPT Charger, demonstrating connections to a starter battery, a lithium house battery, and a solar panel. It also covers setting battery types and understanding LED indicators for charging status.
9. Warranty uye Tsigiro
Ichi chigadzirwa chinouya ne 1-year mugadziri waranti.
For any questions or support regarding your Renogy DC-DC Charger, please contact our customer service team:
- Runhare: 1-909-287-7111 (M-F 8:30am-5pm PST)
- Websaiti: https://www.renogy.com
- Email: support@renogy.com