1. Nhanganyaya
The TSPROF Axicube T2 is a compact and precise digital angle finder designed to assist with sharpening and other angle measurement tasks. Its small size, long battery life, and strong magnetic base make it an indispensable tool for achieving accurate angles.
This manual provides detailed instructions on how to set up, operate, maintain, and troubleshoot your Axicube T2. Please read it thoroughly before first use to ensure optimal performance and longevity of the device.
2. Chii chiri muBhokisi
- Axicube T2 Angle Finder
- USB Type-C Yekuchaja Cable
- Mushandisi Chinyorwa (gwaro iri)
3. Chigadzirwa Pamusoroview

Mufananidzo 3.1: Mberi view of the Axicube T2 with its digital display and control buttons.

Mufananidzo 3.2: Angled view of the Axicube T2, highlighting its compact design.

Mufananidzo 3.3: Pazasi view of the Axicube T2, illustrating the integrated N38 magnets for secure attachment.

Mufananidzo 3.4: Pamusoro view of the Axicube T2, showing the magnetic base plate.
4. Setup uye Kuchaja
4.1 Kutanga Kuchaja
Before first use, fully charge your Axicube T2. Connect the supplied USB Type-C charging cable to the device's charging port and to a standard USB power source (e.g., computer USB port, wall adapter). Charging typically takes 15-20 minutes for a full charge, providing up to 24 hours of operation.
The display will indicate charging status. When the battery is low, the display will show "Lo".
4.2 Kubatidza/Kudzima
Press and hold the power button (usually marked with a circle and a line) to turn the device on or off.
5. Operating Instructions
The Axicube T2 features 4 operating modes suitable for sharpening and general angle measurement. The device is designed to work seamlessly with TSPROF sharpening systems such as K03, Kadet, Pioneer, and Blitz.
5.1 Angle Measurement
To measure an angle, place the Axicube T2 firmly on the surface or sharpening system where you need to determine the angle. The strong N38 magnets ensure a stable attachment.

Figure 5.1: Axicube T2 in use, measuring the angle on a sharpening system.

Mufananidzo 5.2: Imwe view of the Axicube T2 measuring an angle on a sharpening setup.
5.2 Zeroing the Device
To ensure accurate measurements, it is crucial to zero the device on a known flat surface before taking a reading. Press the calibration button (usually marked with a circle) to set the current position as 0.0 degrees.
5.3 Maitiro Okushandisa
The Axicube T2 supports 4 operating modes. Refer to the on-screen indicators or the device's specific button combinations to cycle through these modes. Common modes include absolute angle measurement and relative angle measurement.

Figure 5.3: Axicube T2 displaying an angle, demonstrating its versatility.

Mufananidzo 5.4: Pamusoro-pasi view of the Axicube T2, showing a different angle reading.
6. Maintenance and Battery Replacement
6.1 Kuchenesa
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.
6.2 Kutsiviwa kwebhatiri
The Axicube T2 features a removable Lithium Polymer battery. If the battery needs replacement, carefully open the battery compartment. Refer to the image below for guidance.

Figure 6.1: Axicube T2 with the battery compartment open, revealing the battery and magnetic cover.
- Locate the screws on the back plate of the Axicube T2.
- Carefully unscrew them and remove the magnetic cover plate.
- Gently disconnect the old battery and replace it with a new, compatible Lithium Polymer battery.
- Ensure correct polarity when connecting the new battery.
- Replace the cover plate and secure it with the screws.
Note: Only use genuine replacement batteries or those specified by TSPROF LLC to avoid damage to the device.
7. Kugadzirisa matambudziko
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Chigadzirwa hachishandi. | Bhatiri rakaderera. | Chaja mudziyo uchishandisa tambo yeUSB Type-C yakapihwa. |
| Chiratidziro chinoratidza "Lo". | Bhatiri rakaderera. | Chaja mudziyo nekukurumidza. |
| Kuverengwa kwemakona kusina kururama. | Device not zeroed correctly. | Zero the device on a perfectly flat, level surface before use. |
| Display freezes or malfunctions. | Temporary software glitch or battery connection issue. | Try turning the device off and on again. If the issue persists, open the battery compartment, disconnect and reconnect the battery, then reassemble. |
8. Zvinotsanangurwa
| Feature | Detail |
|---|---|
| Model Number | TS-MS2401580 |
| Dimensions (L x W x H) | 59.5 x 22 x 32 mm (2.35 x 0.87 x 1.26 inches) |
| Kurema | 75 gramu (2.66 ounces) |
| Bhatiri Type | 1 Lithium Polymer bhatiri (inosanganisirwa) |
| Nguva Yekushanda | Up to 24 hours on one charge |
| Kuchaja Nguva | 15-20 minutes via Type-C |
| Magnets | Strong N38 magnets |
| Operating Modes | 4 modes for sharpening and building purposes |
| Kugarisana | TSPROF K03, Kadet, Pioneer, Blitz sharpening systems |
9. Warranty uye Tsigiro
9.1 Ruzivo rweWaranti
TSPROF LLC warrants this product against defects in materials and workmanship for a period specified at the time of purchase. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by misuse, unauthorized modification, accident, or normal wear and tear.
For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact TSPROF customer support.
9.2 Mutengi Tsigiro
If you encounter any issues or have questions regarding your TSPROF Axicube T2, please contact TSPROF LLC customer support. You can find contact information on the official TSPROF websaiti kana kuburikidza nenzvimbo yako yekutenga.
When contacting support, please have your product model number (TS-MS2401580) and a detailed description of the issue ready.