ZIBOO FT-1000W

ZIBOO FT-1000W Solar MPPT Meter Photovoltaic Multimeter

Mushandisi Wemirayiridzo Yekushandisa

1. Nhanganyaya

The ZIBOO FT-1000W Solar MPPT Meter is a professional photovoltaic multimeter designed for accurate testing of solar panels. This device allows users to measure the maximum power point (Pmax), maximum voltage point (Vmp), and maximum current point (Imp) of solar modules. It also provides readings for open-circuit voltage (Voc) and short-circuit current (Isc).

Featuring a comfortable ergonomic design, a large LCD screen for clear readings, and robust safety features like reverse operation protection and internal over-temperature protection, the FT-1000W is an essential tool for solar panel manufacturers, installation technicians, and enthusiasts for both installation and maintenance tasks.

ZIBOO FT-1000W Solar MPPT Meter displaying 800.0W, 00.0V, 00.0A, 00.0V, 00.0A
ZIBOO FT-1000W Solar MPPT Meter in operation.

2. Chengetedzo Yekuchengetedza

Please read and adhere to the following safety guidelines before using the ZIBOO FT-1000W Solar MPPT Meter to ensure safe and correct operation:

  • This product strictly adheres to the safety standards of the Chinese solar energy industry and the safety design standards of the European solar energy industry.
  • Always measure within the specified safety range and the product's corresponding range to prevent damage from incorrect operation.
  • Do not touch conductors with a voltage exceeding 30V during measurement to avoid electric shock.
  • When the measurement exceeds the range, a high-voltage lightning symbol and a buzzer alarm will be displayed. Exercise caution.
  • Do not use the device in flammable, explosive, or other special environments.
  • Replace batteries promptly when the low battery symbol is displayed to avoid measurement errors.
  • Before each measurement, inspect test leads for damage or leakage. Do not use if any damage is found.
  • Ensure correct connection of standard MC4 connectors and verify the positive and negative polarity of the test leads.
  • Pay close attention to all safety symbols and warnings on the device and in this manual.

International Electrical Symbols

SymbolTsanangudzo
▲▲"Caution" indicates an operation that poses a risk.
"High pressure" indicates a warning of high voltage ngozi.
CEEU uniform directive, EU CE certification.
WEEE Recycling SymbolCompliant with the WEEE Recycling Directive.

3. Chigadzirwa Pamusoroview uye Zvikamu

The ZIBOO FT-1000W is designed for ease of use and durability. Its compact size and robust construction make it suitable for field use.

Diagram of ZIBOO FT-1000W Solar MPPT Meter with labeled display elements
Multi-display on one screen for quick judgment of photovoltaic modules.

Tsanangudzo Yechitarisiko

  1. Chiratidziro cheLCD: Shows all measurement values and symbols.
  2. Makiyi ebasa: Buttons for Power, Manual/Auto measurement, and Backlight/Data Hold.
  3. Black Test Input Port (V-): For negative voltage kubatana.
  4. Red Test Input Port (V+): For positive voltage kubatana.
ZIBOO FT-1000W Solar MPPT Meter with labels for PMAX, Vmp, Amp, Voc, Isc, and control buttons
Mberi view of the ZIBOO FT-1000W with display and controls.

Display Symbol Explanation

SymbolTsanangudzo
Pmax (W)Maximum power point (W), the power at which the maximum electricity generation occurs under strong light conditions.
VMP (V)Maximum voltage point (V), the voltage at which the maximum power generation occurs under strong light.
Amp (A)Maximum current point (A), the current at which the maximum power generation occurs under strong light.
Voc (V)Open-circuit voltage, vhoriyamu yakayerwatage when the solar photovoltaic panel is not connected to a load.
Isc (A)Short-circuit current, the current measured when the positive and negative poles of the solar photovoltaic panel are rapidly short-circuited.
MANUALManual measurement: Press once to start the measurement and press again to stop it.
AUTOAutomatic measurement, automatic cyclic measurement.
BATAMaintain data symbols.
Automatic shutdown symbol, automatic shutdown after 10 minutes.
Tembiricha SymbolSymbol for detecting excessive internal temperature of the product.
Yakadzika Voltage ChiratidzoBattery replacement prompt.

4. Setup uye Connection

Before operating the ZIBOO FT-1000W, ensure the batteries are correctly installed and the test leads are properly connected.

Kuiswa kweBattery

The device requires 3 AAA 1.5V batteries. To install or replace batteries:

  1. Ensure the device is powered off and disconnected from any solar panels.
  2. Tsvaga chifukidziro chebhatiri chiri kumashure kwechishandiso.
  3. Unscrew the battery cover screws.
  4. Insert 3 AAA 1.5V batteries, observing correct polarity.
  5. Replace the battery cover and securely tighten the screws.

Kubatanidza Miedzo Inotungamira

The ZIBOO FT-1000W comes with special MC4 test leads for direct connection to solar panels.

  1. Connect the red test lead to the positive input port (V+) on the meter.
  2. Connect the black test lead to the negative input port (V-) on the meter.
  3. Connect the MC4 connectors of the test leads to the corresponding positive and negative terminals of the solar panel. Ensure a secure connection.
Demonstration of connecting the ZIBOO FT-1000W to a solar panel and performing measurements.
Standard MC4 test leads included with the ZIBOO FT-1000W
Standard MC4 test leads for convenient and reliable measurement.

5. Operating Instructions

Simba On/Kudzima

  • Power On: Dzvanya uye bata bhatani remagetsi (Simba bhatani icon) kwemasekonzi matatu.
  • Power Off: Press and hold the power button for 2 seconds. The device will also automatically power off after approximately 10 minutes of inactivity.

Measurement Modes

The ZIBOO FT-1000W offers two measurement modes: Manual and Automatic.

  • Manual Measurement (MANUAL):
    Press the MANUAL button once to initiate a measurement. The device will take a reading and display it. Press again to stop. Each time the Manual button is pressed, wait for 3 seconds to start the test.
  • Automatic Measurement (AUTO):
    Press the AUTO button to enter automatic cyclic measurement mode. The device will continuously refresh data every three seconds, providing real-time readings.

Data Hold (KUBATA)

Panguva yekuyera, tinya iyo BATA button to freeze the displayed data. Pressing it again will release the data hold and resume live readings (or continue automatic measurement if in AUTO mode).

Backlight

To activate the backlight for improved visibility in low-light conditions, press and hold the backlight button (often combined with the HOLD button, indicated by a sun/lightbulb icon) for 3 seconds. Long pressing it again will turn off the backlight.

Test Reference

The meter measures key parameters for solar panels. Understanding these values is crucial for evaluating panel performance:

  • Voltage Zvinotsanangurwa: Common solar photovoltaic panel voltages include 12V, 18V, 24V, 36V, 48V, 60V.
  • Madimikira eSimba: Common solar photovoltaic panel powers include 60W, 100W, 200W, 300W, 500W, 600W, 700W, 800W.
  • Power Calculation: Maximum Power (W) = Maximum Voltage Point (Vmp) × Maximum Current Point (Imp).
    Example: If Vmp = 48.0V and Imp = 11.0A, then Pmax = 48.0V × 11.0A = 528W.

6. Zvinotsanangurwa

ParameterValue (FT-1000W)ResolutionKururama
Simba guru (Pmax)1000W0.1W≤800W ±(1.0%+5), ≥810W ±(1.5%+5)
Kunonyanyisa Voltage (VMP)12-80V0.1V±(1.0%+5)
Maximum Current (Imp)35A0.1A±(1.0%+5)
Vhura Dunhu Voltage (Voc)12-80V0.1V±(1.5%+5)
Short Circuit Current (Isc)35A0.1AN/A
Yakakura Screen Display3.2 inchN/AN/A
Manual/Auto RangeManual/AutoN/AN/A
Beep NotificationEheN/AN/A
BacklightEheN/AN/A
Auto Power OffApprox. Maminitsi makumi maviriN/AN/A
Yakaderera Battery ChiratidzoEheN/AN/A
Data HoldEheN/AN/A
Reverse Input ProtectionEheN/AN/A
BhatiriAAA × 1.5V × 3 PCSN/AN/A
Kukura Kwechigadzirwa143 × 76 × 32 mmN/AN/A
Product Weight390g (ine bhatiri rakajairwa)N/AN/A
ZvitupaCE/EMC/ROHSN/AN/A

Input Protection: Anti-mistake input, positive and negative reverse protection, internal over-temperature protection.

Sampling Rate: 3 times/s; Overload display OL.

Operating Temperature: 0~40°C.

Kururama: 23°C±5°C (18~28°C; Humidity < 75%); 1 year.

Kuchengetedza Tembiricha: -10~60°C; Humidity ≤ 80%.

Pollution Giredhi: 2.

Altitude: 0~2000m.

Product parameters table for ZIBOO FT-1000W and FT-2000W
Detailed chigadzirwa parameters.

7. Kuchengeta

General Maintenance

  • Chengetedza mudziyo wakachena uye wakaoma. Pukuta nechinyoro, damp cloth if necessary. Do not use abrasive cleaners or solvents.
  • Chengetedza mudziyo munzvimbo inotonhorera, yakaoma kure nechiedza chezuva uye tembiricha yakanyanyisa.
  • Only authorized and professionally experienced technicians should open the machine casing for repair. Non-professionals are strictly prohibited from operating to avoid improper repair that may cause damage and electric shock hazards.

Kutsiviwa kwebhatiri

When the low battery symbol appears on the display, replace the batteries immediately to ensure accurate measurements.

  1. Power off the device and disconnect all test leads from any circuits.
  2. Unscrew the battery cover on the back of the unit.
  3. Bvisa mabhatiri ekare AAA.
  4. Insert three new AAA 1.5V batteries, ensuring correct polarity.
  5. Replace the battery cover and securely tighten the screws.

8. Kugadzirisa matambudziko

If you encounter issues with your ZIBOO FT-1000W, consider the following common troubleshooting steps:

  • Hapana Chiratidziro/Chishandiso Chisiri Kuvhurwa: Tarisa kuiswa kwebhatiri uye ona kuti mabhatiri haana kupera. Dzorera kana zvakakodzera.
  • Kuverenga Kusina Kurongeka: Ensure test leads are securely connected to both the meter and the solar panel. Verify that the solar panel is receiving adequate sunlight. Check battery level.
  • "OL" Display: This indicates an overload. The measured value exceeds the device's maximum range. Disconnect immediately and verify the specifications of the solar panel being tested are within the meter's limits (Max 80V, 35A, 1000W).
  • Over-temperature Protection: If the internal temperature exceeds 60°C, the device will stop testing. Allow the meter to cool down before resuming operation.
  • Hapana Mhinduro kubva Mabhatani: Try restarting the device by powering it off and on. If the issue persists, replace the batteries.

If the product malfunction cannot be resolved, please contact customer support.

9. Mazano emushandisi

  • For consistent and accurate readings, perform tests under stable sunlight conditions.
  • Always double-check the polarity when connecting to solar panels to prevent damage to the meter or the panel.
  • Utilize the 'AUTO' mode for quick, continuous monitoring of panel performance, and 'MANUAL' mode for precise, single-point measurements.
  • The 'HOLD' function is useful for recording readings when the display is difficult to view panguva yekuyera.
  • Keep the MC4 dedicated wrench tool handy for secure and easy connection/disconnection of MC4 connectors.

10. Package Zviri mukati

The ZIBOO FT-1000W Solar MPPT Meter package typically includes the following items:

  • ZIBOO FT-1000W Solar MPPT Meter
  • Special Test Lead (MC4 dedicated test cable)
  • AAA 1.5V Batteries (x3)
  • User Manual & Gift Box
  • Strap
  • Special Interface Wrench Tool (x2)
Contents of the ZIBOO FT-1000W package including the meter, test leads, batteries, manual, strap, and wrenches
What's in the box: ZIBOO FT-1000W and accessories.

11. Warranty uye Tsigiro

For any product malfunctions that cannot be resolved through troubleshooting, please contact the official after-sales service. Non-professionals are strictly prohibited from attempting repairs to avoid further damage or electric shock hazards.

Contact Information:

  • Runhare: +86-532-88900998
  • Email: sales-support@ziboo.online

For additional information and resources, you may refer to the official user manual PDF: ZIBOO FT-1000W User Manual (PDF)


ZIBOO FT-1000W Solar MPPT Meter: Photovoltaic Multimeter for Solar Panel Testing

ZIBOO FT-1000W Solar MPPT Meter: Photovoltaic Multimeter for Solar Panel Testing

1:18 • 1280×720 • mirairo

Related Documents - FT-1000W

Preview ZIBOO FT-1000W/FT-2000W Solar MPPT Power Meter User Manual & Specifications
User manual and technical specifications for ZIBOO FT-1000W and FT-2000W Solar MPPT Power Meters, covering safety precautions, general specifications, operation, and maintenance.
Preview User Manual: Earth Clamp Tester (Model UT278A)
Comprehensive user manual for the ZIBOO Earth Clamp Tester, detailing safety precautions, technical specifications, operation methods, and field applications for measuring grounding resistance. Includes instructions for multi-point, limited-point, and single-point grounding systems.
Preview ZIBOO DC Resistance Tester UT620C User Manual
User manual for the ZIBOO DC Resistance Tester (Model UT620C), detailing safety precautions, technical specifications, operation, and accessories for measuring low DC resistance.
Preview Bhuku reMushandisi weYOJOCK USB Power Meter
Bhuku rekushandisa reYOJOCK USB Power Meter, rinotsanangura maparamita echigadzirwa, mirairo yekushandisa, uye maitiro ekuyedza kumhanya kwekuchaja, mhando, uye kugona kwebhangi remagetsi.
Preview Novopal Power Inverter Troubleshooting Guide
Gwaro rakazara rekugadzirisa dambudziko reNovopal Power Inverters, rinovhara zvinhu zvakajairika senge kuwandisa, undervol.tage, pamusoro-voltage, pamusoro-tembiricha, mapfupi maseketi, reverse kubatana, uye hapana DC inopinza voltage. Inosanganisira mhinduro uye tafura yereferensi yebhatiri.