Mustool MT13S

Mustool MT13S 2-in-1 Thermal Imager Multimeter User Manual

Model: MT13S | Brand: Mustool

1. Nhanganyaya

The Mustool MT13S is a versatile 2-in-1 device combining a high-resolution thermal imager with a full-featured digital multimeter. Designed for professionals and enthusiasts, it offers a 10000 count display, a 2.8-inch resistive touch screen, and robust capabilities for electric circuit and automobile inspection. This manual provides essential information for the safe and effective use of your MT13S device.

Mustool MT13S 2-in-1 Thermal Imager Multimeter with key features highlighted
Figure 1: Mustool MT13S Thermal Imager Multimeter highlighting 192*192 IR Resolution, 10000 Counts Multimeter, and 2.8-inch Touch Screen.

2. Package Zviri mukati

Ndokumbira utarise pasuru yezvinhu zvinotevera:

  • 1 x Mustool MT13S Thermal Imaging Multimeter
  • 1 x Type-C USB Cable
  • 1 x Chinyorwa cheMushandisi
  • 1 x Pair yeMuedzo Inotungamira
Mustool MT13S device with included test leads and Type-C USB cable
Figure 2: The Mustool MT13S device and its standard accessories.

3. Mudziyo Pamusoroview

Familiarize yourself with the buttons, display, and ports of the MT13S.

Labeled diagram of Mustool MT13S front panel buttons and display areas
Figure 3: Front panel layout and button functions.
  • Bhatani reSimba: Inobatidza/kudzima mudziyo.
  • Menyu: Accesses various device menus.
  • Multimeter Data Chart Recording: Initiates data logging.
  • IR Camera / Multimeter Switch Button: Inochinja pakati pema "thermal imaging" uye "multimeter modes".
  • Hold / Range Button: Freezes the current reading or switches between auto/manual ranging.
  • Multimeter Frequency / Duty Cycle Switch Button: Inosarudza frequency kana duty cycle kuyerwa.
  • System Setting: Inopinda masisitimu ekugadzirisa sarudzo.
Detailed diagram of the multimeter display elements and measurement modes
Figure 4: Multimeter display description and function icons.
  • Analog Bar: Graphical representation of measurement data.
  • Chiyero data: Displays the primary reading.
  • Kuratidza tembiricha yemumba: Shows ambient temperature.
  • Measurement Modes: V/DC (DC Voltage), V/AC (AC Voltage), Ω (Resistance), Diode, Continuity, Capacitor. Click the screen to switch between these modes.
  • Mabhatani eMenyu ari Pazasi: Function switch menu, Waveform function menu, System settings menu.
  • AUTO: Auto Measure mode.
  • NCV: Isiri-Yekubatanidza Voltage Test.
  • Tembiricha kuyerwa: Indicates temperature reading.

4. Setup

4.1. Kuchaja Chishandiso

The MT13S features a built-in lithium battery. Before first use, ensure the device is fully charged. Connect the provided Type-C USB cable to the device's USB port and to a suitable USB power adapter (not included).

4.2. Kubatanidza Test Leads

For multimeter functions, insert the test leads into the appropriate input jacks:

  • Connect the black test lead to the 'COM' (Common) jack.
  • Connect the red test lead to the 'V-Ω-mA' or 'V-Ω-Vout' jack depending on the measurement type.

5. Operating Instructions

5.1. Simba On / Off

Press and hold the Power Button (refer to Figure 3) to turn the device on or off.

5.2. Mabasa eMultimeter

In multimeter mode, the display shows various measurement options. Use the touch screen or the Multimeter Switch Button to select the desired function:

  • Voltage (V/DC, V/AC): Select DC or AC voltage mode to measure voltage.
  • Kuramba (Ω): Measure resistance of components.
  • Capacitance: Measure capacitance of capacitors.
  • Diode Bvunzo: Test diodes for forward voltage kudonha
  • Continuity Test: Check for circuit continuity with an audible indicator.
  • Frequency/Duty Cycle (Hz/%): Use the dedicated button to measure frequency or duty cycle.

Press the 'Hold/Range' button to freeze the current reading on the display or to switch between auto-ranging and manual ranging modes.

5.3. Thermal Imaging Functions

Press the IR Camera/Multimeter Switch Button to enter thermal imaging mode.

Mustool MT13S performing a thermal inspection of a circuit board
Figure 5: Actual thermal inspection effect on a circuit board.

5.3.1. Adjusting IR Camera Settings

The 2.8-inch resistive touch screen allows for easy adjustment of thermal imaging parameters:

Hand interacting with the resistive touch screen to adjust IR camera settings
Figure 6: Adjusting IR camera settings via the touch screen.
  • Tafura yemavara Select from various color palettes to visualize temperature differences.
  • IR Unit: Choose between Celsius (°C) or Fahrenheit (°F).
  • Emissivity: Adjust the emissivity value (0.1 to 0.99, default 0.95) to match the surface being measured for accurate temperature readings.
  • Frame speed: Adjust the image capture frequency.

5.3.2. Color Palettes

The MT13S offers five distinct color palettes to enhance thermal image interpretation:

Illustration of the five thermal imaging color palettes: Iron Red, Rainbow, Fusion, White Heat, White Heat Highlights
Figure 7: Available thermal imaging color palettes.
  • Iron Tsvuku
  • Muraravungu
  • Fusion
  • Kupisa Kuchena
  • White Heat Highlights

5.4. Data Chart Recording

Utilize the Multimeter Data Chart Recording function to log measurement data over time for analysis.

5.5. Applicable Scenarios

Images showing various applications: circuit board inspection, power maintenance, equipment maintenance, home appliance overhaul
Figure 8: The MT13S is suitable for various applications including circuit board inspection, power maintenance, equipment maintenance, and home appliance overhaul.

6. Zvinotsanangurwa

The following table details the technical specifications of the Mustool MT13S:

Table of technical parameters for Mustool MT13S thermal imaging and multimeter functions
Mufananidzo 9: Detailed technical specifications.
Parameter CategoryParameterMT13S
Thermal Imaging ParametersSensorNdege yakananga isina kutonhorera
Nguva yekutora mufananidzo20Hz
Thermal imaging pixel192*192
Ratidza mufananidzo kugadzirisa240*240
Munda we view (FoV)50.0(H) × 50(V)/72.1(D)
Kusununguka0.1-0.99 is tunable and 0.95 is the default
Chiyero chekushisa chiyero-20°C ~ +550°C
ModeKuwana otomatiki
Ruvara bhodhiIron Red, Rainbow, Fusion, White Heat, White Heat Highlights
Tembiricha kukanganisa>0°C:±2°C or ±2% ≤0°C:±5°C or ±5
Ratidza tembiricha chaiyo0.1°C/0.1F
Multimeter ParametersDC yepamusoro-soro yekupinda vhoriyamutage1000V
AC yepamusoro-soro yekuisa vhoriyamutage750V
Kuramba kupikiswa kwepamusoro-soro99.99MΩ
Kukwanisa kwepamusoro-soro kwekuyera kugona99.99mF
Kuyera kweDiode0V ~ 3V
On-off test maximum resistance999.9Ω
Mamwe Maparamita eMudziyoRatidza nhamba9,999 words updated about 3 times per second
Ratidza Sikirini2.8 inches, 320 by 480 resolution
Bata ScreenResistive touch screen
USB interfaceType-C USB
Kuchengetedza kugona3.5MB
Chimiro chemufananidzoBMP file
BhatiriYakavakwa-mukati lithium bhatiri
Kuchengetedza tembiricha-20~60°C (-4~140F)
Kushanda tembiricha0~50°C (32~122F)
Kushanda humidity<85%RH (Haisi kutonhora)
Chigadzirwa saizi134 mm * 69 mm * 25 mm
Product uremu130g (not including accessories)
Diagram showing the dimensions of the Mustool MT13S
Mufananidzo 10: Zviyero zvechigadzirwa.

7. Kuchengeta

7.1. Kuchenesa

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the casing or screen. Keep the thermal camera lens clean for optimal image quality.

7.2. Kuchengeta

When not in use, store the MT13S in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the device is turned off to conserve battery life.

7.3. Battery Care

To prolong the life of the built-in lithium battery, avoid fully discharging it frequently. Recharge the device regularly, even if it's not in active use, especially if storing for extended periods.

8. Kugadzirisa matambudziko

  • Mudziyo haubatike: Ensure the battery is sufficiently charged. Connect the device to a Type-C USB charger and allow it to charge for some time before attempting to power on again.
  • Inaccurate multimeter readings: Verify that the test leads are correctly connected to the appropriate jacks for the measurement type. Ensure the correct measurement mode is selected on the display. Check if the test leads are damaged.
  • Unclear thermal images: Clean the thermal camera lens with a soft, lint-free cloth. Ensure the emissivity setting is appropriate for the surface being inspected.
  • Bata sikirini haidaire: Try restarting the device. If the issue persists, ensure your fingers are clean and dry when interacting with the resistive touch screen.
  • Device freezes or behaves erratically: Power off the device and restart it. If the problem continues, contact customer support.

9. Mazano emushandisi

  • Always double-check the selected measurement mode before connecting the test leads to a circuit to prevent damage to the device or the circuit.
  • When using the thermal imager, adjust the emissivity setting to match the material you are inspecting for the most accurate temperature readings. Different materials have different emissivities.
  • For detailed analysis, utilize the Multimeter Data Chart Recording feature to capture and review measurement trends over time.
  • Keep the thermal camera lens free from dust and smudges to ensure clear and accurate thermal images.
  • The compact size and built-in battery make the MT13S ideal for fieldwork; always ensure it's fully charged before heading out.

10. Warranty uye Tsigiro

Kuti uwane ruzivo rwewaranti, rutsigiro rwehunyanzvi, kana kubvunza sevhisi, ndapota taura nemutengesi kana mugadziri zvakananga. Chengeta risiti rako rekutenga seumboo hwekutenga.

Related Documents - MT13S

Preview MUSTOOL MT8206 Digital Graphical Multimeter User Manual
This user manual provides comprehensive instructions and technical specifications for the MUSTOOL MT8206 Digital Graphical Multimeter, covering its features, operation, safety precautions, and measurement functions.
Preview MUSTOOL MT826 Digital Multimeter User Manual: Zvimiro, Kushanda, uye Kuchengetedza
Yakazara mushandisi bhuku reMUSTOOL MT826 Digital Multimeter. Dzidza nezveT-RMS/USB yayo maficha, mashandiro akadzama, mirairo yekuchengetedza, hunyanzvi hwekuita, uye kugadzirisa zviyero zvemagetsi.
Preview MDS 2112P Digital Storage Oscilloscope Quick Guide
Quick start guide for the MUSTOOL MDS 2112P Digital Storage Oscilloscope, covering safety precautions, panel descriptions, user interface, basic operations, and appendix information.
Preview MUSTOOL Laser Level User Manual - Features, Operation, and Specifications
Comprehensive user manual for the MUSTOOL Laser Level, covering features, safety precautions, operating instructions, specifications, and maintenance. Includes details for 3D and 4D models.
Preview MUSTOOL Product Compliance Certificate - FCC Declaration
Declaration of Conformity yeMUSTOOL zvigadzirwa, zvichisimbisa kutevedza neFCC Chikamu 15 Chikamu B chemirau yeradiation uye conduction emission.