SMART SENSOR ST8100B

ST8100B Handheld Oxygen Gas Analyzer

Muenzaniso: ST8100B | Brand: SMART SENSOR

1. Nhanganyaya

The ST8100B is a precision oxygen concentration instrument designed for accurate and rapid measurement of oxygen (O₂) gas. It utilizes an electrochemical gas sensor for quick response and features manual alarm level setup with both light and sound indicators. This device is suitable for various environments including homes, workshops, petroleum refining facilities, petrochemical plants, and for oxygen content detection in vehicles and industrial settings where oxygen is used or monitored.

ST8100B Handheld Oxygen Gas Analyzer front view
Mufananidzo 1: Mberi view of the ST8100B Oxygen Gas Analyzer.

2. Safety Information

Ndapota verengai uye nzwisisai mirairo yese yekuchengetedza musati mashandisa mudziyo. Kukundikana kutevedzera mirairo iyi kunogona kukonzera kukuvara kana kukuvara kwemudziyo.

  • Usaedze kugadzirisa kana kugadzirisa mudziyo. Tumira mabasa ese ekugadzirisa kune vashandi vane hunyanzvi.
  • Ensure proper battery installation and replacement as specified.
  • Dzivisa kuisa mudziyo munzvimbo dzinopisa zvakanyanya, hunyoro, kana kuti dzine ngura.
  • Chengetedza mudziyo kure neminda yakasimba yemagetsi.
  • Always operate the device within its specified operating conditions.
  • This device is for measurement purposes only and should not be used as a primary safety device in critical life-support systems without additional safety measures.

3. Chigadzirwa Pamusoroview

The ST8100B is designed for ease of use and portability. Key components and controls are outlined below:

ST8100B Product Introduction with labeled parts
Figure 2: Labeled components of the ST8100B Oxygen Gas Analyzer.
  • Sensor: Located at the top, responsible for detecting oxygen concentration.
  • Ratidza: Large LCD screen showing measurement results and other indicators.
  • Batanidza/Kudzima: Inosimbisa kana kudzima mudziyo.
  • Backlight/▼ key: Controls display backlight and navigates menus downwards.
  • Mode kiyi: Inochinja pakati pemamodhi akasiyana ekushanda.
  • Sound/▲ key: Controls audible alarm and navigates menus upwards.
  • UNIT kiyi: Inochinja mayuniti ekuyera.
ST8100B Dimensions
Figure 3: Dimensions of the ST8100B device (167mm height, 56mm width, 27mm depth).
Sensitive Probe details
Figure 4: Sensitive probe details, highlighting 0.1% resolution, ≤±2% basic error, and ≤15 seconds response time.

4. Zvinotsanangurwa

Feature Tsanangudzo
BrandSMART SENSOR / OEM
Model NumberST8100B
DisplaySegment LCD backlight display
Gas TypeOxygen meter
Measuring Range0 ~ 30% VOL
Resolution0.1%
Basic Error≤±3% F·S
Temperature Range-20℃~50℃ (accuracy ±2℃)
Humidity Range1%RH~99%RH
Nguva YekupinduraPasina 15 seconds
Nguva YekudzoreraPasina 15 seconds
Kuyera NheyoElectrochemical principle, life for 2 years
Alarm SettingLow / High Alarm setting
Alarm ModeSound and light dual alarm
Operating Temperature-10℃~50℃ (except LEL is 0 ~40℃)
Kushanda Humidity0-95% RH (isina-condensing)
Storage Temperature0 ~ 40 ℃
Product Weight / Size138g / 57*28*167mm
Implementation StandardGB12358-2006
Magetsi3x1.5V AAA battery
Battery Working RuntimeAbout 100 hours of continuous use (when backlight is off)
PackingGift Bhokisi
Kurongedza Zviri mukati1 * Oxygen Detector, 1 * USB Cable, 1 * Hose, 1 * Carrying Case, 1 * User Manual (English)
Oxygen Concentration Measurement conditions
Figure 5: Working humidity (0-95%RH Non Gel) and working temperature (-20 ~ 50°C) for oxygen concentration measurement.
Key features of the ST8100B
Figure 6: Key features including sensitive probe, max value display, high-definition backlight, acoustic-optical alarm, temperature display, and low current display.

5. Setup

5.1. Kuiswa kwebhatiri

The ST8100B requires three (3) 1.5V AAA batteries for operation. Batteries are not included with the device.

  1. Tsvaga chivharo chebhatiri kuseri kwemudziyo.
  2. Slide the cover open in the direction indicated.
  3. Insert three 1.5V AAA batteries, ensuring correct polarity (+/-) as marked inside the compartment.
  4. Vhara chivharo chebhatiri zvakachengeteka.
Battery installation for ST8100B
Figure 7: Battery compartment showing installation of 3x1.5V AAA batteries.

5.2. Chekutanga Power On

Press and hold the On/Off button (usually the red power button) until the display illuminates. The device will perform a self-test and then enter the measurement mode.

6. Operating Instructions

6.1. Kutora Zviyero

Once powered on, the device will automatically begin measuring oxygen concentration in the surrounding environment. The current oxygen percentage and temperature will be displayed on the HD backlit LCD screen.

HD Backlight Display in operation
Figure 8: The HD Backlight Display shows oxygen concentration and temperature readings.

6.2. Kuchinja Zvikamu

Press the 'UNIT' key to cycle through available measurement units if applicable (e.g., for temperature display between Celsius and Fahrenheit).

6.3. Kugadzirisa Kukosha kweAlarm

The ST8100B allows you to set both low and high alarm thresholds for oxygen concentration.

  1. Enter the alarm setting mode (refer to the device's on-screen prompts or specific button combinations if available).
  2. Use the '▲' (Sound) and '▼' (Backlight) keys to adjust the 'LO ALM' (Low Alarm) value.
  3. Confirm the low alarm setting.
  4. Use the '▲' and '▼' keys to adjust the 'HI ALM' (High Alarm) value.
  5. Confirm the high alarm setting to save.
Alarm Value Setting for Low and High thresholds
Figure 9: Display showing Low Alarm Value Setting (LO ALM) and High Alarm Value Setting (HI ALM).

7. Ma alarm

The ST8100B is equipped with a high-decibel buzzer and a visual display alarm. When the detected oxygen concentration falls below the 'LO ALM' value or rises above the 'HI ALM' value, the instrument will activate both audible and visual alarms to alert the user.

Buzzer and Display Alarm illustration
Figure 10: Illustration of the light and audible alarm indicators.

8. Effects of Oxygen Concentration on Humans

Understanding the effects of varying oxygen levels is crucial for safety. The table below outlines the symptoms associated with different oxygen concentrations in the atmosphere (at standard atmospheric pressure).

Oxygen Concentration (%) Symptoms (Atmospheric Pressure)
100%Deadly, 6 minutes (Absolutely airtight environment, such as hyperbaric oxygen chamber)
50%Deadly, can be cured after 45 minutes treatment. (Absolutely airtight environment, such as hyperbaric oxygen chamber)
>23.5%Rich oxygen
20.96%Normal
19.5%Minimum
15~19%Reduce efficiency, and lead to problems of head, lung and circulation system
10~12%Shortness of breath, loss of judgment, purple lips
8~10%Governance loss, syncope, unconscious, pale, nausea and vomiting
6~8%8 minutes, blood pressure, weak heartbeat, mouth breathing, quickly stopped breathing
4~6%40 seconds, convulsions, respiratory arrest, death

9. Kuchengeta

  • Kuchenesa: Pukuta mudziyo nekanyoro, damp jira. Usashandise abrasive cleaners kana solvents.
  • Kuchengeta: Kana usingashandiswe kwenguva yakareba, bvisa mabhatiri wochengeta mudziyo wacho munzvimbo inotonhorera, yakaoma, kure nezuva rakananga uye tembiricha yakanyanya.
  • Sensor Care: The electrochemical sensor has a life of approximately 2 years. Regular calibration is recommended to ensure accuracy, though this device does not specify user calibration.
  • Kutsiva Bhatiri: Replace batteries promptly when the low battery indicator appears on the display to ensure continuous accurate operation.

10. Kugadzirisa matambudziko

If you encounter issues with your ST8100B, please refer to the following common problems and solutions:

  • Mudziyo haubatike:
    • Tarisa kana mabhatiri akaiswa zvakanaka aine polarity chaiyo.
    • Tsiva nemabhatiri eAAA matsva.
  • Kurava kusina kururama:
    • Ita shuwa kuti sensor yakachena uye haina kuvharwa.
    • Verify the device is operating within its specified temperature and humidity ranges.
    • Allow the device to stabilize in the environment for a few minutes before taking critical readings.
  • Alarm not sounding/flashing:
    • Check if alarm settings (LO ALM, HI ALM) are configured correctly.
    • Ensure the sound is not muted (if a mute function exists).

Nezvezvinoramba zvichiitika, tapota taura nerutsigiro rwevatengi.

11. Mazano emushandisi

  • The device's battery working runtime is approximately 100 hours of continuous use when the backlight is off. To conserve battery life, turn off the backlight when not needed.
  • Always ensure the English version of the user manual is available for reference.
  • Consider the various applications of the device, such as oxygen generator purity testing, chemical industry monitoring, gallery area safety, oxygen cylinder concentration detection, mountaineering, and agricultural planting, to maximize its utility.
Applications of the oxygen detector
Figure 11: Various applications for the ST8100B Oxygen Detector.

12. Warranty uye Tsigiro

12.1. Warranty

Ichi chigadzirwa chinouya ne 1-makore waranti from the date of purchase. During the warranty period, if any quality problem arises, please provide photos to demonstrate the issue. The manufacturer will determine whether to send replacement parts or request the instrument for repair or exchange. Please contact customer support before returning any product. You will be responsible for double-run freight costs.

12.2. Tsigiro

For technical assistance, troubleshooting, or warranty claims, please refer to the contact information provided with your purchase or visit the official SMART SENSOR website.

13. Ruzivo rwekambani

SMART SENSOR is a professional manufacturer and seller of instruments with over 10 years of experience in instrument development and production. The company boasts a strong R&D team and collaborates with domestic universities to develop cutting-edge technology. Their products, including smart multimeters, clamp meters, DC power supplies, laser distance meters, infrared thermometers, vibration meters, thickness gauges, sound level meters, anemometers, temperature hygrometers, range finders, gas detectors, metal detectors, voltage insulation meters, earth resistance testers, and leakage current testers, are known for their quality and market share. OEM/ODM services are available for all models.

Company building exterior
Mufananidzo 12: Kunze view of the company building.
Company office and workshop images
Figure 13: Images showing the company's office, production workshop, and soldering workshop.
Product assembly and testing processes
Figure 14: Images illustrating product assembly, voltage comparison test, current comparison test, and second re-inspection processes.

14. Certifications

The ST8100B Oxygen Gas Analyzer complies with relevant international standards and holds the following certifications:

  • CE Certification
  • FCC Certification
  • RoHS Kutevedzera
Certifications for the product including CE, FC, RoHS
Figure 15: Certificates of Compliance (CE, FC, RoHS).

15. Mibvunzo Inowanzo bvunzwa (FAQ)

Q: Does your company accept customization?
A: Yes, we offer customizing services for customers, including OEM/ODM. Any logo and color can be customized. An English copy of the manual is also available.
Q: What is the warranty of the product?
A: We offer a 12-month warranty. Within the warranty period, if there is any quality problem, please send us photos to show the problem. We will then decide to send you parts or have you send the instrument back for repair or exchange. Please contact us first before sending it back directly. You will only need to pay for double-run freight.

Related Documents - ST8100B

Preview Bhuku reMirayiridzo yeSMART SENSOR AR8100 Oxygen Detector
Bhuku remirayiridzo reSMART SENSOR AR8100 portable oxygen detector. Dzidza kushandisa, kugadzirisa, uye kunzwisisa kuverenga kuti ukwanise kuyera oxygen level nenzira chaiyo munzvimbo dzakasiyana-siyana.
Preview SMART SENSOR AS8800C Combustible Gas Detector Instruction Manual
User manual for the SMART SENSOR AS8800C Combustible Gas Detector. Provides detailed information on technical specifications, display features, operation instructions, safety precautions, and common gas properties for detecting flammable gases.
Preview SMART SENSOR AR816 Anemometer Instruction Manual
Yakakwana yekuraira Chinyorwa cheSMART SENSOR AR816 Anemometer, inodonongodza mabasa ayo, mashandiro, uye tekinoroji zvirevo zvekumhanya kwemhepo uye kuyerwa kwekushisa.
Preview Smart Sensor Gas Detectors and Monitors - Product Catalog
Explore the comprehensive range of Smart Sensor gas detectors and monitors, including multi-gas, single-gas, and specialized detectors for various industrial and safety applications. View specifications, features, and packing details.
Preview SMART SENSOR ST335A Digital Brix Refractometer - Data Sheet
Product data sheet for the SMART SENSOR ST335A Digital Brix Refractometer, detailing its features, specifications, and applications for measuring sugar concentration in food and beverages.