The AKO-D14918 programming key allows you to quickly and easily copy configured settings from one controller to another with the same functionality
Yambiro
-Using the equipment without following the manufacturer’s instructions may affect the device’s safety requirements.
-The unit must be used in a location protected from vibrations, water and corrosive gases, where the ambient temperature does not exceed that shown in the technical data.
-Connecting this key to unsupported devices (see table) can cause serious damage to both pieces of equipment.
-In equipment with active communication, log out of communications software or disconnect the cable before connecting the programming key. The communication controller’s address must be 1.
Tsanangudzo

- LED COM
- REKODI CHINOKOSHA
- EXTERNAL POWER CONNECTOR
- READ KEY
- Akatungamirira ON
- CONNECTOR CABLE
Kugarisana
Refer to the instruction manual of your equipment on its compatibility with the AKO-D14918 programming key.
Connecting incompatible devices can permanently damage the key.
Wiring

- ZVINOKOSHA: Pay attention to the orientation of the connector.
- AKO-80018
(Sarudzo) - AKO-D14918
Magetsi
-If the controller is in operation (on-site programming), the key does not require an external power supply (it is powered via the connecting cable).
-If the controller is NOT powered (workshop programming), the key requires a 12Vdc/500 mA external power supply (AKO-80018 or equivalent).
Operation
ZVINOKOSHA: After connecting the key to the equipment wait for 5 seconds before starting the reading or writing process.
RECORD key
Write the data contained in the key memory to the controller.
Keep the key pressed until the COM led starts flashing quickly.
When recording is complete the controller will reset.
READ key
It reads the data from the controller and stores them in the programming key.
Keep the key pressed until the COM led starts flashing quickly.
When recording is complete the controller will reset.
Akatungamirira ON
Steady or flashing: Indicates that the key is connected to the controller.
LED COM
Yakatsiga: Indicates an error in the transmission/reception of data
Kurumidza kupenya: Indicates transmission/reception of data in progress. At the end of the transmission LED COM ichadzima.
Kupenya zvishoma: Indicates compatibility error- the data contained in the memory of the key is not compatible with the model of controller connected. Data can only be read from the controller to the key.
CHERECHEDZA: To restart after a transmission or compatibility error, turn off the power supply or disconnect the controller connector cable.
ZVINOKOSHA: Never disconnect the programming key during data transmission.
Zvido zvehunyanzvi
Length of cable from programming key to controller . . . . . . . . . . . . . 300 mm
Mugove voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Vdc nominal
Supply current . . . . . . . . . . . . . . . . . . . . . . . . . . . . AKO-80018 / 500 mA máx.
Environmental specifications:
Ambient working temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . 0ºC to 50ºC
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -30ºC to 70ºC
![]()
AKO ELECTROMECÁNICA, SA
Av. Roquetes, 30-38 | 08812 Sant Pere de Ribes | Barcelona | España
35D149181 REV.07 2025
Isu tinochengeta kodzero yekupa zvinhu zvinogona kusiyana zvishoma kune izvo zvinotsanangurwa muTechnical Sheets.
Ruzivo rwakagadziridzwa runowanikwa pane yedu website.
Zvinyorwa / Zvishandiso
![]() |
AKO D14918 Programming Key [pdf] Bhuku reMirayiridzo AKO-D14918, AKO-80018, D14918 Programming Key, Programming Key, Key |