This manual provides instructions for the installation, operation, and maintenance of the Intermatic T174 DPST 24 Hour Time Switch. This electromechanical timer is designed for controlling electrical loads over a 24-hour period.

Intermatic T174 DPST 24 Hour Time Switch with Type 1 Indoor Enclosure

Image: Intermatic T174 DPST 24 Hour Time Switch. This image shows the front view of the timer with its gray metal enclosure and the dial for setting time.

Safety Information

WARNING: Risk of electric shock. Installation and servicing must be performed by qualified personnel only. Disconnect power at the circuit breaker or fuse box before installing or servicing the timer.

  • Nguva dzose tevera makodhi emagetsi emunharaunda nemitemo.
  • Ensure the power supply matches the timer's voltage rating (208-277V AC).
  • Do not exceed the maximum current and horsepower ratings of the timer.
  • This device is intended for indoor use in a Type 1 enclosure.

Package Zviri mukati

The Intermatic T174 Time Switch package typically includes:

  • One (1) Intermatic T174 Time Switch Unit
  • Instruction Guide
  • Two (2) Trippers for setting ON/OFF times

Setup uye Installation

The Intermatic T174 is designed for fixed installation. Proper wiring is crucial for safe and correct operation.

Mounting

  1. Choose a suitable indoor location for mounting the timer, ensuring it is protected from moisture and extreme temperatures.
  2. Securely mount the timer's enclosure to a wall or suitable surface using appropriate fasteners.

Wiring (DPST Configuration)

The T174 features a Double Pole, Single Throw (DPST) contact form, meaning it controls two independent circuits or a single 2-pole circuit simultaneously.

  1. DISCONNECT ALL POWER to the circuit at the main service panel before proceeding.
  2. Open the timer's enclosure.
  3. Connect the incoming power lines (L1 and L2 for 208-277V AC) to the designated "LINE" terminals on the timer.
  4. Connect the load wires (to the device being controlled) to the designated "LOAD" terminals. Ensure correct polarity if applicable.
  5. Ita shuwa kuti zvese zvinongedzo waya dzakasimba uye dzakachengeteka.
  6. Close the timer's enclosure securely.
  7. Dzosera simba kudunhu.

Bvunza nyanzvi yemagetsi kana usina chokwadi nezvenzira dzekubatanidza waya.

Operating Instruction

The T174 uses a mechanical dial and trippers to set the ON/OFF schedule.

Kuisa Iyo Yazvino Nguva

  1. Rotate the timer dial clockwise until the current time aligns with the "TIME SET" arrow or indicator on the timer mechanism.
  2. Ensure AM/PM is correctly observed if the dial has such markings.

Kugadzirisa Nguva Dzekuvhura/Kudzima

The timer comes with two trippers: one "ON" tripper and one "OFF" tripper. Additional trippers can be purchased separately (Extra Trippers 11Z965).

  1. Locate the "ON" tripper (typically silver or light-colored) and the "OFF" tripper (typically black or dark-colored).
  2. Snap the "ON" tripper onto the dial at the desired time you want the connected device to turn ON.
  3. Snap the "OFF" tripper onto the dial at the desired time you want the connected device to turn OFF.
  4. You can set up to 12 ON/OFF cycles per 24-hour period using additional trippers. The minimum time setting is 1 hour.

Manual Override

The T174 typically includes a manual override switch or lever. This allows you to temporarily turn the connected device ON or OFF without affecting the programmed schedule. Refer to the specific markings on your timer for the manual override function.

Day Skipper Function

The timer features a Day Skipper function, allowing you to prevent operation on specific days of the week. Consult the detailed instruction guide included with your unit for specific setup of this feature.

Maintenance

The Intermatic T174 Time Switch is designed for reliable, long-term operation with minimal maintenance.

  • Periodically inspect the timer for any signs of damage or loose connections.
  • Keep the enclosure clean and free from dust and debris.
  • Do not attempt to lubricate internal components.

Kugadzirisa matambudziko

Dambudziko Zvinogona Kukonzera Solution
Timer haishande. Hapana simba kune timer. Check circuit breaker or fuse. Ensure wiring connections are secure.
Connected device does not turn ON/OFF at programmed times. Incorrect tripper placement or current time setting. Verify tripper positions and ensure the current time is accurately set on the dial. Check manual override switch position.
Timer motor is noisy. Normal operation for some mechanical timers. If noise is excessive or new, contact support.
Timer operates but device does not. Faulty wiring to the load or issue with the connected device. Verify load wiring. Test the connected device directly to ensure it is functional.

Zvinotsanangurwa

Feature Detail
Model Number T174
Type Electromechanical Timer
Operation 24-Hour
Uwandu Matanda 2
Contact Form DPST-NO (Double Pole, Single Throw - Normally Open)
Voltage 208-277V AC
Ampage 40 A
Contact HP @ 120V 2 hp
Contact HP @ 240V 5 hp
Day Skipper Ehe
Enclosure Type Steel, Type 1 Indoor Enclosure
Finish Gray Enamel
Kugadzika Nguva Ishoma 1 awa
Maximum Time Setting 23 maawa
Kumhanya Kwakanyanya Kwekuvhurwa/Kudzimwa 12
Zviyero (H x W x D) 7 13/16 in x 5 in x 3 in (Approximate)
Item Weight 2.75 - 2.8 Mapaundi
Included Trippers 2
UPC 078275174214
Mugadziri Intermatic Incorporated

Warranty uye Support

The Intermatic T174 Time Switch comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your product or visit the official Intermatic website.

For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Intermatic customer service. You can often find support information and additional resources on the Intermatic Store on Amazon kana kambani yavo yepamutemo website.

Related Documents - T174

Preview Intermatic T105 24-Hour Dial Time Switch: Kuisa, Kuisa Wiring, uye Gwaro reKushanda
Gwaro rakakwana reIntermatic T105 mechanical dial time switch rinotora maawa makumi maviri nemana. Rinovhara marongero emhando, yambiro dzekuchengetedza, mirairo yekubatanidza waya yemhando dzakasiyana-siyana (SPNO, SPNC, SPDT), maitiro ekugadzira mapurogiramu, uye mashandiro nemaoko. Rinosanganisira tafura yakadzama yekuongorora magetsi uye mazano ekuenzanisa waya.
Preview Intermatic T103 24-Hour Dial Time Switch: Bhuku reKuisa uye reKushanda
Gwaro rakadzama reIntermatic T103 24-Hour Dial Time Switch, rinosanganisira zvirevo, yambiro dzekuchengetedza, mirairo yewaya, mapurogiramu, uye mashandiro. Yakakodzera kushandiswa mumba ne120/208/240 VAC power.
Preview Intermatic T170, T1400 & T1800 Series Electromechanical Time Switches
Ruzivo rwakakwana pamusoro peIntermatic T170, T1400, uye T1800 Series 24-Hour Electromechanical Time Switches, inosanganisira maficha, magadzirirwo, ma ratings, kusiyana kwemamodheru, uye madhayagiramu ewiring ezvemabhizinesi, maindasitiri, uye edzimba.
Preview Intermatic T104 24-Hour Dial Time Switch - Specifications and Instructions
Comprehensive guide for the Intermatic T104 24-hour dial time switch, detailing its specifications, electrical ratings, safety warnings, wiring instructions, programming procedures, and operating guidelines. Includes technical data and troubleshooting tips.
Preview Intermatic EJ351 Indoor Wall Switch Timer: Kuisa, Kuronga, uye Kugadzirisa Matambudziko
Yakakwana gwara rekuisa, kuronga, uye kugadzirisa iyo Intermatic EJ351 Indoor Wall Switch Timer. Dzidza maitiro ekuseta mashedhi, shandisa otomatiki uye emaoko modhi, uye kugadzirisa zvinowanzoitika.
Preview Gwaro reKuisa uye Kushanda kweIntermatic Spring Wound Interval Timer
Gwaro rakadzama rekuisa, kushanda, uye gwara rekushandisa reIntermatic spring wound interval timers (FF neFD models). Rinosanganisira ma switch ratings, wiring diagrams, uye ruzivo rwewarandi.