1. Nhanganyaya
The Dickson TM320 is a versatile data logger designed to accurately monitor and record temperature and humidity levels. Featuring a large display for real-time readings, audio/visual alarms, and convenient data transfer options via USB and flash card, it provides essential environmental monitoring for various applications. Its user-friendly design ensures ease of use and reliable performance.
- USB Enabled Download: Easily transfer recorded data to a computer.
- Flash Memory Data Transfer Capability: Utilize flash cards for convenient data retrieval.
- Jumbo Display: Clear and easy-to-read real-time measurements.
- Zviri Nyore Kushandisa: Intuitive interface for straightforward operation.
2. Safety Information
Please read all safety instructions before operating the device. Failure to do so may result in damage to the device or personal injury.
- Do not expose the device to extreme temperatures outside its specified operating range.
- Avoid direct contact with water or high humidity environments beyond the non-condensing range.
- Shandisa manyuko emagetsi nezvimwe zvinhu zvakatarwa chete.
- Usaedze kuvhura kana kugadzirisa mudziyo wega. Tumira masevhisi ese kuvashandi vanokwanisa.
- Chengetedza pasingasvikirwi nevana.
3. Package Zviri mukati
Tarisa uone kuti zvinhu zvese zviripo mupakeji:
- Dickson TM320 Data Logger
- Chinyorwa Chirairo (gwaro iri)
- USB Cable (may be sold separately)
- SD Card (may be sold separately)
- Batteries (may be pre-installed or included)
4. Chigadzirwa Pamusoroview

Mufananidzo 4.1: Mberi View. Shows the large digital display, 'DICKSON' branding, and three control buttons: MIN/MAX, ALARM, and SAVE.

Mufananidzo 4.2: Rutivi View nePorts. Illustrates the mini-USB port for data transfer and external sensor input jacks, along with ventilation for internal sensors.

Mufananidzo 4.3: Kudzoka View. Displays the battery compartment cover and keyhole slots for wall mounting.

Mufananidzo 4.4: Pamusoro View. Shows the slot for inserting an SD card for data storage and transfer.
5. Setup
5.1. Kuiswa kwebhatiri
- Tsvaga kamuri yebhatiri kuseri kwechigadzirwa (ona Mufananidzo 4.3).
- Svetera chivharo chebhatiri chivhure.
- Insert the required batteries (typically AA or AAA, check compartment for type) ensuring correct polarity (+/-).
- Vhara chivharo chebhatiri zvakachengeteka.
5.2. Simba rekutanga-Kubatidza
The device should power on automatically once batteries are installed. The display will illuminate, showing current readings or a startup sequence.
5.3. Kuisa Chishandiso
The TM320 can be placed on a flat surface or mounted on a wall:
- Surface Placement: Ensure the device is placed on a stable, level surface away from direct heat sources or extreme drafts.
- Kuisa madziro: Use appropriate screws (not included) with the keyhole slots on the back of the device (refer to Figure 4.3) to secure it to a wall. Ensure it is mounted in a location representative of the environment you wish to monitor.
6. Kushanda
6.1. Kunzwisisa Chiratidziro
The jumbo display provides real-time information:
- Ikozvino Kuverenga: Shows the live temperature or humidity value.
- Zviyuniti: Indicates Fahrenheit (F) or Celsius (C) for temperature, and %RH for humidity.
- Chiratidzo chebhatiri: Inoratidza hupenyu hwebhatiri hwasara.
- CH (Chiteshi): Indicates which channel is currently displayed (e.g., CH 1 for temperature, CH 2 for humidity).
6.2. Bhatani Mabasa
- Bhatani reMIN/MAX: Press to cycle through minimum, maximum, and current readings for both temperature and humidity. Hold to reset min/max values.
- ALARM Bhatani: Dzvanya ku view current alarm settings. Hold to enter alarm setting mode (refer to section 6.4).
- SAVE Bhatani: Press to manually save a data point.
6.3. Dhata Logging
The TM320 automatically logs data at a pre-set interval. Data can be viewed on the display or downloaded to a computer.
6.4. Kuisa maaramu
The device features audio/visual alarms for out-of-range conditions.
- Dzvanya uye ubate iyo ALARM button until the alarm setting mode is activated.
- Shandisa iyo MIN / MAX button to navigate between temperature and humidity alarm settings (high/low).
- Shandisa iyo SAVE button to adjust the alarm threshold values.
- Press ALARM zvakare kusimbisa uye kubuda iyo yekuseta modhi.
6.5. Data Download (USB)
- Connect the TM320 to your computer using a compatible USB cable (refer to Figure 4.2 for port location).
- The device should be recognized as a removable storage device or require specific Dickson software (refer to manufacturer's website for software).
- Follow the software instructions to download and analyze the logged data.
6.6. Data Transfer (Flash Card)
If your model supports flash card data recovery:
- Insert a compatible SD card into the SD card slot (refer to Figure 4.4).
- The device may automatically transfer data or require a specific button press (consult software/manual for details).
- Remove the SD card and insert it into a computer's card reader to access the data.
7. Kuchengeta
7.1. Kuchenesa
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the sensor vents or ports.
7.2. Kutsiviwa kwebhatiri
Replace batteries when the low battery indicator appears on the display. Follow the battery installation steps in Section 5.1.
7.3. Kuchengeta
When not in use for extended periods, remove the batteries and store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
8. Kugadzirisa matambudziko
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Mudziyo haubatike. | Mabhatiri akafa kana kuti akaiswa zvisirizvo. | Tarisa bhatiri polarity; chinja nemabhatiri matsva. |
| No data is being logged. | Device not powered on; memory full; logging paused. | Ensure device is on; download data to clear memory; check software settings for logging status. |
| Display shows 'Err' or abnormal readings. | Sensor malfunction; out of range conditions. | Move device to a stable environment; contact support if error persists. |
| Cannot download data via USB. | Incorrect cable; driver issue; software not installed. | Ensure correct USB cable; install necessary drivers/software from Dickson website. |
| Alarm haisi kurira. | Alarm disabled; volume too low; thresholds set incorrectly. | Check alarm settings (Section 6.4); ensure alarm is enabled and thresholds are appropriate. |
9. Zvinotsanangurwa
| Feature | Detail |
|---|---|
| Model Number | TM320 |
| Temperature Range | -4 kusvika 158°F (-20 kusvika 70°C) |
| Humidity Range | 0-95% RH (isina-condensing) |
| Mugadziri | Dickson Unigage Inc. |
| Product Dimensions | 19.56 x 16.51 x 8.89 masendimita (7.7 x 6.5 x 3.5 inches) |
| Product Weight | 385.55 g (0.85 lbs) |
| Data Transfer | USB, Flash Card (SD) |
| Display | Jumbo LCD |
10. Warranty uye Tsigiro
This product is covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Dickson website. For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Dickson customer service through their official channels.
Dickson Official Websaiti: www.dicksonlogger.com