Watts 007 QT

Watts 007 QT 1/2-inch Double Check Valve Assembly Instruction Manual

1. Chigadzirwa Pamusoroview

The Watts 007 QT 1/2-inch Double Check Valve Assembly is engineered to prevent the backflow of contaminated water into a potable water supply system. This device is suitable for non-health hazard, continuous pressure applications. Its robust bronze body construction ensures durability and ease of maintenance. The assembly provides protection against both backsiphonage and backpressure backflow, safeguarding water quality.

Zvinhu zvakakosha zvinosanganisira:

Watts 007 QT 1/2-inch Double Check Valve Assembly

Image 1.1: Watts 007 QT 1/2-inch Double Check Valve Assembly. This image displays the bronze body construction and overall compact design of the valve assembly.

2. Safety Information

YAMBIRO: Improper installation or maintenance of this device can lead to serious injury or property damage. Always adhere to local plumbing codes and regulations.

3. Setup uye Kuiswa

The Watts 007 QT Double Check Valve Assembly is designed for horizontal or vertical installation, depending on local codes and specific model requirements. Ensure proper orientation for optimal performance.

3.1 Pre-Instalation Checks

3.2 Matanho ekuisa

  1. Vhara Mugove Wemvura: Locate the main water shut-off valve and turn off the water supply to the area where the backflow preventer will be installed. Drain the system to relieve pressure.
  2. Sarudza Nzvimbo: Choose an accessible location for installation that allows for future maintenance and testing. The device should be installed downstream of the main water meter and upstream of any connections that could introduce contaminants.
  3. Gadzirira Mapaipi: Cut and prepare the existing piping to accommodate the 1/2-inch inlet and outlet connections of the valve assembly. Ensure pipe ends are clean and free of burrs.
  4. Isa Valve: Install the Watts 007 QT assembly into the pipeline, ensuring the flow arrow on the valve body points in the direction of water flow. Use appropriate thread sealant on all connections.
  5. Simbisa Zvisungo: Securely tighten all connections to prevent leaks, but do not overtighten, which could damage the bronze body or fittings.
  6. Open Water Supply: Slowly open the main water shut-off valve to gradually repressurize the system. Check all connections for leaks.
  7. Kuedza Kwekutanga: After installation, the device should be tested by a certified backflow prevention device tester to ensure proper operation and compliance with local regulations.

4. Kushanda

The Watts 007 QT Double Check Valve Assembly operates automatically to prevent backflow. It contains two independently operating check valves that close to prevent reverse flow when a backflow condition occurs.

5. Kuchengeta

Regular maintenance and testing are crucial to ensure the continued proper function of your Watts 007 QT Double Check Valve Assembly. This device is designed for ease of service.

5.1 Annual Testing

Local regulations typically require annual testing of backflow prevention devices by a certified tester. This ensures the device is operating correctly and providing the required level of protection.

5.2 Kushandira uye Kugadzirisa

The modular construction and top-entry design facilitate easy servicing. If testing indicates a malfunction, the internal components can be accessed and replaced without removing the entire assembly from the pipeline.

6. Kugadzirisa matambudziko

This section provides guidance for common issues. For complex problems or issues related to backflow prevention, always consult a certified professional.

6.1 Matambudziko Anowanikwa uye Magadzirirwo

If you encounter issues not listed here or are unsure about a repair, contact Watts customer support or a qualified plumbing professional.

7. Zvinotsanangurwa

Model Number007 QT (Part # 0062131)
Size1/2 inch
MaterialBronze, Silicone
Exterior FinishBronze
Inlet Connection Size0.5 inches
Inlet Connection TypeKaviri Check Valve Assembly
Outlet Kubatanidza Saizi0.5 inches
Outlet Connection TypeFNPT
Maximum Operating Pressure175 psi (12.06 bar)
Nhamba yePorts2
Item Weight3.45 makirogiramu
Zviyero zveChigadzirwa (L x W x H)1 x 0.39 x 0.39 inches
Tsanangudzo MetASSE 1015, AWWA C510, CSA B64.5, IAPMO PS31

8. Warranty uye Tsigiro

For specific warranty information regarding your Watts 007 QT Double Check Valve Assembly, please refer to the documentation included with your purchase or visit the official Watts website. Warranty terms typically cover manufacturing defects under normal use and service.

8.1 Mutengi Tsigiro

If you require technical assistance, have questions about installation, operation, or maintenance, or need to inquire about replacement parts, please contact Watts customer support:

When contacting support, please have your product model number (007 QT) and any relevant purchase information readily available.

Related Documents - 007 QT

Preview Watts Series 007, LF007 Double Check Valve Assemblies Installation, Maintenance, and Repair Manual
Comprehensive guide for installing, maintaining, and troubleshooting Watts Series 007 and LF007 Double Check Valve Assemblies. Includes safety warnings, installation procedures, servicing instructions, troubleshooting tips, and warranty information.
Preview Watts Stainless Steel Double Check Valve GBS Kit (007-SS-GBS) - Technical Data
Technical specifications, product codes, dimensions, and features for the Watts 007-SS-GBS Stainless Steel Double Check Valve with Geared Butterfly Valve and Strainer. Designed for backflow prevention in medium and low hazard installations.
Preview Watts Series 709, LF709, 709DCDA Double Check Valve Assemblies: Installation, Maintenance, and Repair Manual
Comprehensive guide for the installation, maintenance, and repair of Watts Series 709, LF709, and 709DCDA Double Check Valve Assemblies and Double Check Detector Assemblies, covering sizes 2½" to 10". Includes installation guidelines, servicing procedures, troubleshooting, and information on add-on monitoring kits.
Preview Watts Series 757, 757DCDA, LF757DCDA Double Check Valve Assemblies Installation, Maintenance, and Repair Manual
Comprehensive guide for installing, maintaining, and repairing Watts Series 757, 757DCDA, and LF757DCDA Double Check Valve and Detector Assemblies, covering procedures, troubleshooting, and warranty information.
Preview Watts Series LF007 Double Check Valve Assembly: Installation, Maintenance, and Repair Manual
Comprehensive guide for the Watts Series LF007 Double Check Valve Assembly, covering installation, maintenance, troubleshooting, and warranty. Essential for ensuring safe and efficient water system operation.
Preview Watts 007-SS-LBS Stainless Steel Double Check Valve Technical Data
Technical data sheet for the Watts 007-SS-LBS Silver Stallion Stainless Steel Double Check Valve Kit, featuring dimensions, product codes, technical specifications, and characteristic curves for water supply protection.