1. Nhanganyaya
This instruction manual provides comprehensive guidance for the installation, operation, and maintenance of the Sloan Royal 111 Exposed Manual Water Closet Flushometer, 1.28 GPF. This flushometer is engineered for commercial restroom applications, offering reliable performance and water conservation through its non-hold-open handle and fixed metering bypass. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product.

Figure 1: Sloan Royal 111 Exposed Manual Water Closet Flushometer.
2. Safety Information
Always observe basic safety precautions during installation and maintenance. Failure to do so may result in personal injury or property damage.
- Ensure the main water supply is turned off before beginning any installation or repair work.
- Pfekai michina yekudzivirira muviri yakakodzera (PPE), yakaita semagirazi ekuchengetedza uye magirovhosi.
- If you are unsure about any part of the installation or repair process, consult a qualified plumber.
- This product contains brass castings which may expose you to lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
3. Package Zviri mukati
Tarisa kuti zvese zviriko zviripo usati watanga kuisa:
- Sloan Royal 111 Flushometer Assembly
- Flush Valve
- Adjustable Tailpiece
- 1" I.P.S. Screwdriver Bak-Chek Angle Stop with free-spinning vandal-resistant stop cap
- Vacuum Breaker Flush Connection with one-piece bottom hex coupling nut
- Diaphragm, Handle Packing, and Vacuum Breaker molded from PERMEX rubber compound

Mufananidzo 2: Yakaputika view of Sloan Royal Flushometer components, showing internal parts like the diaphragm, handle, and vacuum breaker.
4. Setup uye Kuiswa
The Sloan Royal 111 Flushometer is designed for wall-mounted installation with a top spud fixture connection. Professional installation is recommended.
4.1 Pre-Instalation Checks
- Verify that the rough-in dimensions match the product specifications.
- Ensure the water supply line is clean and free of debris.
- Confirm that the water pressure is within the recommended range for optimal flushometer performance.
4.2 Matanho ekuisa
- Gadzirira Kupa Mvura: Turn off the main water supply. Install the 1" I.P.S. screwdriver Bak-Chek angle stop to the water supply pipe, ensuring the vandal-resistant stop cap is securely in place.
- Assemble Tailpiece: Attach the adjustable tailpiece to the flushometer body. The adjustable design allows for flexibility to accommodate various plumbing configurations.
- Connect to Fixture: Connect the flushometer assembly to the top spud of the water closet using the vacuum breaker flush connection and its one-piece bottom hex coupling nut. Ensure all connections are hand-tightened, then use a wrench for a final snug fit, being careful not to overtighten.
- Chengetedza kuWall: Secure the flushometer to the wall using appropriate mounting hardware (not always included, check package).
- Tarisa uone Mavuza: Batidza mvura huru zvishoma nezvishoma uye tarisa maburi ese ari kuburitswa mvura. Simbisa maburi ese ari kuburitswa mvura kana zvichidikanwa.
5. Operating Instructions
The Sloan Royal 111 Flushometer features a manual, non-hold-open handle for single-flush operation, promoting water conservation.
5.1 Flushing the Water Closet
- To activate the flush, simply push the ADA-compliant metal oscillating handle down firmly and release.
- The non-hold-open design ensures that the flush cycle completes automatically, preventing continuous flushing and excessive water usage.
- The flushometer is designed to deliver 1.28 gallons per flush (GPF) for efficient waste removal.
Video 1: Official Sloan video demonstrating the operation of Sloan Royal Flushometers, highlighting their features and use in commercial settings.
Video 2: Official Sloan video providing an overview of the Sloan Royal Flushometer, showcasing dhizaini yayo uye mashandiro ayo.
6. Kuchengeta
Regular maintenance ensures optimal performance and extends the life of your Sloan Royal 111 Flushometer.
6.1 Kuchenesa
- Clean the exterior chrome finish with a mild soap and water solution. Avoid abrasive cleaners or harsh chemicals, as these can damage the finish.
- Pukuta wakaoma nemucheka munyoro kudzivirira mavara emvura.
6.2 Diaphragm and Rubber Components
- The flushometer's diaphragm, handle packing, and vacuum breaker are made from PERMEX rubber compound, which offers high resistance to chloramines.
- Periodically inspect these components for wear or damage. If any part appears worn, replace it with genuine Sloan replacement parts to maintain performance and water efficiency.
7. Kugadzirisa matambudziko
This section addresses common issues you might encounter with your flushometer.
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Insufficient Flush Volume | Low water pressure; partially closed control stop; worn diaphragm. | Check water supply pressure; fully open the control stop; inspect and replace diaphragm if worn. |
| Kuyerera Kwemvura Inoenderera | Debris in the diaphragm bypass; worn diaphragm; improper handle assembly. | Clean diaphragm bypass; replace diaphragm; reassemble handle correctly. |
| Leaking at Connections | Loose connections; damaged gaskets or O-rings. | Tighten connections; replace damaged gaskets or O-rings. |
8. Zvinotsanangurwa
| Feature | Detail |
|---|---|
| Model Number | 3910168 |
| Brand | Sloan |
| Material | Brass (High Copper, Low Zinc) |
| Exterior Finish | Chrome (Polished) |
| Flush Volume | 1.28 Galoni Per Flush (GPF) |
| Bata Type | Manual, Non-Hold-Open, ADA-Compliant Metal Oscillating Handle |
| Inlet Connection Size | 1 inch |
| Inlet Connection Type | Sravana Sameeralu Serial 4th Top Spud |
| Outlet Kubatanidza Saizi | 1.5 inches |
| Outlet Connection Type | Sravana Sameeralu Serial 4th Top Spud |
| Dezincification Resistance | Yes, due to high copper, low zinc brass castings |
| Rubber Zvikamu | PERMEX rubber compound (resistant to chloramine) |
| Dimensions (L x W x H) | 9.75 x 9.13 x 4.38 inches |
| Item Weight | 6.46 makirogiramu |
| Installation Method | Wall Mounted |
| CID Technology | Yes, for flush accuracy and clog resistance |
9. Warranty uye Tsigiro
Sloan products are manufactured under strict quality standards. For specific warranty details and terms, please refer to the warranty card included with your product or visit the official Sloan website. For technical support, replacement parts, or service inquiries, please contact Sloan customer service.
Sloan Contact Information:
- Websaiti: www.sloan.com
- Basa reVatengi: Tarisa kurongedza kwechigadzirwa kana websaiti yenhamba dzedunhu.