Sure-Lites LPX7

Sure-Lites LPX7 Universal Emergency Exit Light User Manual

Model: LPX7 | Brand: Sure-Lites

Nhanganyaya

The Sure-Lites LPX7 Series LED Exit Light is a universal emergency exit sign designed for general purpose applications. This unit features a durable polycarbonate housing and is equipped with LED lamps, offering energy efficiency and reliability. It supports dual voltage input (120/277 VAC) and includes a nickel cadmium battery for emergency operation, providing a minimum run time of 90 minutes during power loss.

The LPX7 series is engineered for ease of installation and maintenance, making it a suitable replacement for previous models like the CCX Series. It ships with components to configure either red or green exit legends, providing flexibility for various installation requirements.

Sure-Lites LPX7 Universal Emergency Exit Light

Figure 1: Sure-Lites LPX7 Universal Emergency Exit Light with red legend illuminated.

Safety Information

Ndapota verengai uye nzwisisai mirairo yese musati maisa kana kushandisa chigadzirwa ichi. Kukundikana kutevedzera mirairo iyi kunogona kukonzera kuvhunduka kwemagetsi, moto, kana dzimwe njodzi dzinogona kukonzera kukuvara kwepfuma kana kukuvara kwemunhu.

Package Zviri mukati

Tarisa kuti zvese zviriko zviripo uye hazvina kukuvara usati watanga kuisa:

Setup & Kuisa

The LPX7 exit sign is designed for universal mounting, allowing for ceiling, wall, or end mount installations. Follow these steps for proper setup:

1. Sarudzo Yenzvimbo

Choose a mounting location that is visible and meets local building codes for emergency exit signage. Ensure the mounting surface is structurally sound to support the unit's weight.

2. Kubviswa Simba

Before starting any electrical work, turn off power to the circuit at the main breaker panel to prevent electric shock.

3. Mounting Gadziriro

Determine the desired mounting method (ceiling, wall, or end mount). The unit is designed for semi-flush mount installation. Refer to the dimensions diagram for precise measurements.

Dimensions of Sure-Lites LPX7 Emergency Exit Light

Figure 2: Dimensional drawing of the LPX7 exit light, showing overall width of 13 inches (330mm), overall height of 7 1/2 inches (190mm), and overall depth of 2 1/8 inches (54mm).

4. Kubatana kweMagetsi

Connect the unit to a 120 VAC or 277 VAC, 60 Hz power source. The LPX7 features dual voltage input. Ensure proper wiring according to the provided wiring diagram (typically found inside the unit or on a separate sheet). All connections must be secure and insulated.

5. Battery Connection

Connect the internal Nickel Cadmium (NiCAD) battery. The battery is typically pre-installed but may require connecting a small plug to the circuit board. Ensure the connection is firm.

6. Legend Configuration

Insert the desired red or green legend panels into the unit. The LPX7 ships with both options, allowing for field configuration.

7. Gungano Rekupedzisira

Secure the unit to the mounting surface using the provided hardware. Ensure the housing is properly closed and secured.

8. Power Restoration & Testing

Restore power to the circuit. The exit sign should illuminate. Press the "TEST" button (usually a small push-button on the side or bottom of the unit) to verify emergency operation. The unit should switch to battery power and remain illuminated for at least 30 seconds. Release the button, and the unit should return to AC power.

Operation

The Sure-Lites LPX7 Emergency Exit Light operates automatically. When connected to a continuous AC power source, the LED lamps will remain illuminated, indicating the exit path. The internal Nickel Cadmium battery continuously charges while AC power is present.

Emergency Mode

Pakaitika simba outage or interruption to the AC supply, the unit will automatically switch to emergency mode, drawing power from its internal battery. The LED lamps will remain illuminated for a minimum of 90 minutes, providing essential egress lighting.

Test Bhatani

A test button is provided on the unit for routine maintenance checks. Pressing and holding this button simulates a power failure, allowing you to verify that the battery and lamps are functioning correctly in emergency mode. Release the button to return to normal AC operation.

Emergency exit light installed in a waiting area

Mufananidzo 3: Example installation of an emergency exit light in a commercial waiting area, demonstrating its function in a public space.

Emergency exit light installed in an auditorium

Mufananidzo 4: Example installation of an emergency exit light in an auditorium, highlighting its visibility in a large gathering space.

Maintenance

Regular maintenance ensures the continued reliable operation of your emergency exit light. Always disconnect power before performing any maintenance.

Monthly Testing

Perform a monthly 30-second test by pressing the test button. The unit should operate on battery power for the duration of the test. If the lamps do not illuminate or dim significantly, the battery may need replacement or further charging.

Annual Testing

Conduct an annual 90-minute discharge test. Disconnect AC power to the unit and allow it to operate on battery power for 90 minutes. The lamps should remain illuminated for the entire duration. If the unit fails to operate for 90 minutes, the battery requires replacement.

Kuchenesa

Chenesa kunze kwechinhu nguva nenguva uchishandisa soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the polycarbonate housing.

Kutsiviwa kwebhatiri

The Nickel Cadmium battery has a typical lifespan of 5-7 years. If the unit fails to meet the required emergency run time during testing, replace the battery with an approved Sure-Lites replacement battery. Ensure proper polarity when connecting the new battery.

Kugadzirisa matambudziko

If your Sure-Lites LPX7 Emergency Exit Light is not functioning as expected, refer to the following common issues and solutions:

DambudzikoZvinogona KukonzeraSolution
Unit does not illuminate when AC power is on.No AC power to the unit; Loose wiring connection; Faulty LED lamps.Check circuit breaker and power supply. Verify all wiring connections are secure. Contact qualified service personnel if lamps are faulty.
Unit does not illuminate in emergency mode (during test or power outaguye).Battery not connected; Battery not charged; Battery has reached end of life; Faulty circuit board.Ensure battery is properly connected. Allow 24 hours for initial battery charge. Replace battery if it fails annual test. Contact qualified service personnel.
Lamps are dim in emergency mode.Battery not fully charged; Battery nearing end of life.Allow unit to charge for 24 hours. If problem persists, replace battery.

If the problem persists after attempting these solutions, contact Sure-Lites customer support or a qualified electrician.

Zvinotsanangurwa

FeatureDetail
Model NumberLPX7
Chiyamuro Voltage120/277 VAC, 60 Hz
Light SourceLED (2 Lamps)
Rudzi Tembiricha5000K
Legend ColorConfigurable Red or Green
Legend Height6 inches
Mounting TypeUniversal (Ceiling, Wall, End Mount)
Housing MaterialPolycarbonate
Housing ColorChena
Bhatiri TypeNickel Cadmium (NiCAD)
Emergency Run NguvaMaminitsi makumi maviri mashoma
Overall Height7.5 inches (190mm)
Upamhi Hwose13 inches (330mm)
Kwose Kudzika2.125 inches (54mm)
Item Weight2.88 makirogiramu

Warranty uye Support

Warranty Information

The Sure-Lites LPX7 Emergency Exit Light comes with a 5-makore waranti from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. The warranty does not cover damage resulting from improper installation, misuse, abuse, or acts of nature.

Mutengi Support

For technical assistance, warranty claims, or replacement parts, please contact Sure-Lites customer support. Refer to the Sure-Lites official websaiti kana chigadzirwa kurongedza kune yazvino ruzivo ruzivo.

Cherechedza: Always provide your product model number (LPX7) and date of purchase when contacting support to expedite assistance.

Related Documents - LPX7

Preview Sure-Lites EBPLEDL6SF Emergency LED Driver - Product Specifications and Data
Detailed specifications, features, and installation data for the Sure-Lites EBPLEDL6SF Emergency LED Driver by Cooper Lighting Solutions. Includes product overview, technical data, certifications, and dimensional drawings.
Preview Sure-Lites EBP1400NCX/NCF Emergency Ballast Installation Manual
Comprehensive installation, operation, and maintenance guide for Sure-Lites EBP1400NCX and EBP1400NCF emergency ballasts, detailing safety precautions, wiring diagrams, and lamp kugarisana.
Preview Sure-Lites FirstLink Connected Emergency Lighting System | Cooper Lighting Solutions
Explore the Sure-Lites FirstLink connected emergency lighting system from Cooper Lighting Solutions. This brochure details system features, hardware, app control, and service plans designed for building safety and code compliance.
Preview Sure-Lites ELX Series LED Exit Sign - Technical Specifications
Detailed technical specifications for the Sure-Lites ELX Series self-powered LED exit signs, including features, construction, code compliance, energy data, and mounting options.
Preview Sure-Lites APEL Series Emergency Lighting Fixture
Ongorora iyo Sure-Lites APEL Series mwenje wechimbichimbi, ine UL 924 runyorwa, 90-maminetsi ekumhanya, inogadzirika LED misoro, uye yakasimba nickel cadmium bhatiri. Yakanakira yakavimbika emergency egress ine kure kure kugona sarudzo.
Preview Sure-Lites EBPLED Emergency Battery Packs: 7W & 14W LED Emergency Lighting
Datasheet for Sure-Lites EBPLED series LED emergency battery packs. Features 90-minute run time, constant wattage output, LiFePO4 battery, and UL 924 compliance for 7W and 14W models, suitable for various commercial applications.