The Altronix R2416300UL is a rack mount power supply designed to provide 24VAC or 28VAC power for various applications, particularly commercial CCTV equipment. This unit features 16 individually fused outputs, ensuring reliable power distribution and protection. It is housed in a durable steel enclosure and includes a line cord, spare fuse, removable terminal blocks, and mounting brackets for convenient installation.

2. Ruzivo Rwakakosha Chekuchengetedza

Please read these safety instructions carefully before installing or operating the Altronix R2416300UL power supply. Failure to follow these instructions may result in electric shock, fire, or damage to the unit.

Altronix R2416300UL Rack Mount Power Supply Front View

Mufananidzo 1: Mberi view of the Altronix R2416300UL Rack Mount Power Supply. This image shows the black steel enclosure with the Altronix logo and 16 green LED indicators for each output. A caution label for electric shock is visible on the right.

3. Setup uye Kuiswa

3.1. Kusunungura

Carefully remove the power supply from its packaging. Verify that all components are present: the R2416300UL unit, line cord, spare fuse, removable terminal blocks, and mounting brackets.

3.2. Mounting

The R2416300UL is designed for rack mounting. Use the provided mounting brackets to secure the unit into a standard 19-inch equipment rack. Ensure the rack is stable and provides adequate support for the unit's weight (approximately 17.2 pounds).

3.3. Input Power Connection

  1. Ensure the power switch on the rear of the unit is in the "OFF" position.
  2. Connect the supplied line cord to the AC input receptacle on the rear of the power supply.
  3. Plug the other end of the line cord into a grounded 115VAC, 60Hz power outlet.
Altronix R2416300UL Rack Mount Power Supply Rear View

Mufananidzo 2: Kumashure view of the Altronix R2416300UL Rack Mount Power Supply. This image displays the power switch, AC input, and the array of 16 output terminal blocks. The product label with specifications is also visible.

3.4. Output Connections

The R2416300UL provides 16 individually fused 24VAC or 28VAC outputs. Each output is equipped with a removable terminal block for easy wiring.

  1. Identify the desired output terminal block (labeled 1 through 16).
  2. Connect your device's power input wires to the corresponding terminals on the removable block. Ensure correct polarity if applicable to your device.
  3. Securely insert the wired terminal block into its receptacle on the power supply.
  4. Repeat for all devices requiring power.
Altronix R2416300UL Rear Label and Terminal Blocks Close-up

Figure 3: Close-up of the rear product label and output terminal blocks. This image provides a detailed view of the product specifications, safety warnings, and the green removable terminal blocks for connecting output devices.

4. Operating Instructions

4.1. Powering On / Off

4.2. Output Indicators

The front panel of the R2416300UL features 16 green LED indicators, one for each output. A lit green LED indicates that the corresponding output is receiving power and the fuse is intact.

Altronix R2416300UL Front Panel LED Indicators Close-up

Figure 4: Close-up of the front panel showing the 16 green LED indicators. Each LED corresponds to an individual fused output, providing a visual status of power delivery.

5. Kuchengeta

5.1. General Care

5.2. Fuse Replacement

If an output LED is off, the corresponding fuse may be blown. To replace a fuse:

  1. Power Off: Disconnect the unit from the main power supply by unplugging the line cord.
  2. Identify Blown Fuse: Locate the fuse holder for the affected output on the rear panel.
  3. Bvisa Fuse: Carefully remove the blown fuse.
  4. Install New Fuse: Replace it with a new fuse of the exact same type and rating: 3.5A, 250V. Using an incorrect fuse can cause damage or fire.
  5. Dzosera Simba: Reconnect the unit to the main power supply and turn it on. Verify the output LED illuminates.

6. Kugadzirisa matambudziko

DambudzikoZvinogona KukonzeraSolution
No power to the unit (no LEDs lit).
  • Tambo yemagetsi haina kubatana.
  • Hapana simba kubva pakubuda.
  • Kukanganisa kwemukati.
  • Ita shuwa kuti tambo yemagetsi yakavharirwa mukati zvakachengeteka.
  • Edza nzira yekubuditsa mvura uchishandisa chimwe chishandiso.
  • Contact Altronix technical support.
One or more output LEDs are off.
  • Blown fuse for that output.
  • Short circuit or overload on the output.
  • Replace the fuse (3.5A, 250V).
  • Check the connected device for faults or excessive current draw.
Unit powers on, but connected devices do not function.
  • Wiring isiriyo.
  • Kutadza kwemudziyo.
  • Kubuda voltage mismatch.
  • Wona kuti zvese zvinongedzo ndezvechokwadi.
  • Test device with another power source if possible.
  • Confirm device requires 24VAC or 28VAC.

7. Zvinotsanangurwa

FeatureDetail
BrandAltronix
Model NumberR2416300UL
Chiyamuro Voltage115VAC (Minimum 110V, Maximum 115V)
Input Frequency60 Hz
Kubuditsa Voltage24VAC kana 28VAC
Output Current (24VAC)12.5A
Output Current (28VAC)10A
Huwandu hwezvinhu zvakasanganiswa16
Fuse Type/Rating3.5A, 250V
Fomu FactorRack Gomo
Enclosure MaterialSimbi
FinishNhema
Zviyero zveChigadzirwa (L x W x H)19.13 x 8.5 x 3.27 inches
Item Weight17.2 Pondo
MitemoUL 2044 Commercial CCTV, CUL, CE
Kutonhodza NziraAir

8. Warranty uye Tsigiro

8.1. Ruzivo rweWaranti

Altronix products are typically backed by a limited lifetime warranty. For specific warranty terms and conditions applicable to your R2416300UL unit, please refer to the official Altronix websaiti kana kubata basa ravo revatengi zvakananga. Chengeta risiti rako rekutenga seumboo hwekutenga.

8.2. Technical Support

For technical assistance, installation questions, or troubleshooting beyond the scope of this manual, please contact Altronix technical support. You can find their contact information on the official Altronix websaiti (www.altronix.com).

Related Documents - R2416300UL

Preview Altronix ALTV244UL Series CCTV Power Supplies Installation Guide
Installation guide for Altronix ALTV244UL series CCTV power supplies, detailing models, specifications, installation instructions, and enclosure dimensions. Features 24VAC/28VAC outputs with fuse or PTC protection for CCTV cameras and video accessories.
Preview Altronix VertiLine24 Series CCTV Rack Mount Power Supplies Installation Guide
Comprehensive installation guide for Altronix VertiLine24 Series CCTV Rack Mount Power Supplies, covering models VertiLine24, VertiLine246, VertiLine24D, and VertiLine246D. Includes specifications, detailed installation instructions, mounting options, safety warnings, and troubleshooting tips.
Preview Altronix ALTV2432 Series 32-Output CCTV Power Supply Installation Guide
Installation guide for the Altronix ALTV2432 Series 32-output CCTV power supplies, detailing models, specifications, and installation instructions for 24VAC and 28VAC operation.
Preview Altronix ALTV2416 Series 16-Output CCTV Power Supplies Installation Guide
Installation guide for Altronix ALTV2416 Series 16-Output CCTV Power Supplies, detailing models, specifications, features, installation instructions, terminal identification, and enclosure dimensions.
Preview Altronix ALTV1224C4220 AC/DC Dual Output Power Supply Installation Guide
Installation guide for the Altronix ALTV1224C4220 AC/DC Dual Output Power Supply, detailing specifications, installation steps, fuse replacement, and terminal identification for providing 12VDC and 24VAC outputs.
Preview Gwaro rekuisa magetsi reAltronix ALTV244UL3 Series CCTV
Gwaro rekuisa Altronix ALTV244UL3 Series CCTV Power Supplies, mamodheru ane ruzivo rwakadzama ALTV244UL3, ALTV244ULX3, ALTV244175UL3, ALTV244ULCB3, uye ALTV244175ULCB3. Inosanganisira chigadzirwa pamusoro peview, zvirevo, mirairo yekuisirwa, kuzivikanwa kwechiteshi, uye saizi yenzvimbo yacho.