Leviton 1254-R

Leviton 15 Amp 125 Volt Industrial Grade 4-in-1 Receptacle (Model 1254-R) Instruction Manual

Muenzaniso: 1254-R

1. Nhanganyaya

This manual provides detailed instructions for the safe installation, operation, and maintenance of the Leviton 15 Amp, 125 Volt, Industrial Series Extra Heavy Duty Grade, 4-In-1 Receptacle, Model 1254-R. This device is designed for demanding environments requiring high-abuse tolerance, such as healthcare facilities, manufacturing plants, and educational institutions. It features four outlets in a single-gang footprint, offering increased power access without requiring larger electrical boxes.

2. Safety Information

YAMBIRO: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. All wiring must be in accordance with national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

3. Package Zviri mukati

The package for the Leviton 1254-R 4-in-1 Receptacle typically includes:

4. Zvinotsanangurwa

FeatureDetail
Model Number1254-R
Ampage15 Amp
Voltage125 Volt
GiredhiIndustrial Series Extra Heavy Duty Grade
Receptacle Type4-In-1, Straight Blade, Grounding
ColorTsvuku
MaterialThermoplastic Nylon (Cover and Body)
Wiring OptionsBack and Side Wiring
ContactsExtra Heavy-Duty, T-type triple-wipe bronze
DimensionsInenge 8 x 8 x 8 inches (Zviyero zveChigadzirwa)
KuremaAnenge 6.4 ounces

5. Kuiswa

Follow these steps for proper installation of your Leviton 4-in-1 Receptacle. If you are not familiar with electrical wiring, consult a qualified electrician.

  1. Dzima Simba: Locate the circuit breaker or fuse that controls the outlet where you intend to install the receptacle. Turn it OFF. Verify that the power is off using a voltage muedzo.
  2. Remove Old Receptacle (if applicable): Unscrew the wall plate and then the mounting screws holding the existing receptacle in the electrical box. Carefully pull the old receptacle out of the box.
  3. Dimbura Waya: Disconnect the wires from the old receptacle. Note which wire was connected to which terminal (hot, neutral, ground).
  4. Gadzirira Waya: Strip approximately 1/2 inch of insulation from the ends of the wires if necessary. Ensure the wire ends are clean and straight.
  5. Connect Wires to New Receptacle:
    • Batanidza iyo HOT (Black or Red) waya ku Brass terminal screws.
    • Batanidza iyo NEUTRAL (Ichena) waya ku Sirivha terminal screws.
    • Batanidza iyo GROUND (Green or Bare Copper) waya ku Girinhi grounding screw.

    This receptacle supports both back-wiring (inserting wires into holes on the back and tightening screws) and side-wiring (wrapping wires around terminal screws). Ensure connections are tight and no bare wire is exposed outside the terminals.

    Leviton 1254-R 4-in-1 Receptacle, Red

    Mufananidzo 5.1: Mberi view of the Leviton 1254-R 4-in-1 Receptacle in Red. This image shows the four outlets and the robust construction.

    Close-up of receptacle wiring terminals

    Mufananidzo 5.2: Pedyo-up view of a Leviton receptacle's wiring terminals, illustrating the side-wiring option and the grounding screw.

  6. Mount Receptacle: Carefully push the wired receptacle back into the electrical box. Secure it with the provided mounting screws.
  7. Isa Wall Plate: Namatira ndiro yemadziro pamusoro pechinhu chinobikirwa mvura.
  8. Dzosera Simba: Turn the circuit breaker or fuse back ON.
  9. Muedzo: Plug a device into each of the four outlets to ensure proper function.

The 1254-R features an interlocking thermoplastic nylon cover and body for enhanced durability and a nickel-plated brass strap with integral ground contacts for reliable grounding. The permanent "Green Dot" marking on the face indicates its hospital/industrial grade compliance.

Close-up of receptacle with green dot marking

Image 5.3: Detail showing the "Green Dot" marking, signifying the industrial/hospital grade rating of the receptacle.

6. Kushanda

The Leviton 1254-R 4-in-1 Receptacle operates like any standard electrical outlet. Simply insert the plug of your electrical device into one of the four available receptacles. Ensure the plug is fully inserted for a secure connection. The extra heavy-duty, T-type triple-wipe bronze contacts provide maximum performance and a strong grip on cords.

7. Kuchengeta

This industrial-grade receptacle requires minimal maintenance. Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power at the circuit breaker and replace the receptacle immediately. Clean the surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.

8. Kugadzirisa matambudziko

DambudzikoZvinogona KukonzeraSolution
Hapana simba pachigaro.Circuit breaker tripped or fuse blown. Loose wiring connection.Check and reset the circuit breaker or replace the fuse. Turn off power and inspect wiring connections for tightness.
Device plug feels loose in the outlet.Worn contacts (unlikely for new industrial grade). Incorrect plug type.Ensure the plug is fully inserted. If the issue persists, and the receptacle is old, consider replacement. Verify plug compatibility.
Receptacle is warm to the touch.Overload on the circuit. Loose wiring connection.Disconnect some devices to reduce load. Turn off power and check wiring connections. If warming persists, consult an electrician.

9. Ruzivo rweWaranti

Leviton products are backed by a limited warranty. For specific warranty terms and conditions applicable to the 1254-R receptacle, please refer to the warranty documentation included with your purchase or visit the official Leviton website. Chengetedza humbowo hwako hwekutenga kune warranty claim.

10. Tsigiro

For technical assistance, product information, or customer support, please visit the official Leviton website or contact their customer service department. Contact details can typically be found on the product packaging or the Leviton website.

Leviton Websaiti: www.rrevitd.de

Related Documents - 1254-R

Preview Leviton GFCI Outlet ine USB Ports Installation uye Operation Manual
Gwara rakazara rekuisa nekushandisa Leviton GFCI Outlets ine USB Ports, kusanganisira mirairo yewaya, yambiro yekuchengetedza, maitiro ekuyedza, uye ruzivo rwewaranti.
Preview Kuisa nekuyedza Leviton Smart GFCI Outlet: Gwara Rakazara
Mirayiridzo yedanho nedanho yekuisa nekuyedza Leviton Smart GFCI outlets (modheru D2GF1, D2GF2). Dzidza nezve mashandiro eGFCI, waya dzemagetsi, kugadzirisa matambudziko, uye matanho ekuchengetedza.
Preview Gwaro rekuisa nekuongorora reLeviton SmartlockPro GFCI Receptacle
Gwaro rakakwana rekuisa nekuyedza mareceiptor eLeviton SmartlockPro Ground Fault Circuit Interrupter (GFCI). Rinovhara matanho ekuchengetedza, waya dzemagetsi, kugadzirisa matambudziko, uye maficha ezvigadzirwa.
Preview Gwaro rekuisa nekuongorora reLeviton GFCI Receptacle
Gwaro rakakwana rekuti ungaisa uye uedze sei Leviton SmartLock Pro GFCI Receptacle, kusanganisira mirairo yekubatanidza waya, matanho ekuchengetedza, uye mazano ekugadzirisa matambudziko.
Preview Leviton GFNT1-DIN/GFNT2-DIN DIN Rail Mount GFCI Receptacle Installation Guide
Yakakwana gwara rekuisa uye kuyedza Leviton's GFNT1-DIN uye GFNT2-DIN DIN DIN Rail Mount GFCI Receptacles, kusanganisira mirairo yewaya, kuchengetedza, uye kugadzirisa matambudziko.
Preview Leviton Smart Wallbox Sensors: Elevate Your Sensing Control Options
Discover Leviton Smart Wallbox Sensors for commercial applications, offering occupancy/vacancy sensing, dimming, switching, energy savings, and code compliance for offices, meeting rooms, and lobbies. Learn about key features and benefits.