1. Nhanganyaya
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Taco 006-B4 Bronze Circulator Pump. The Taco 006-B4 is designed for circulating hot or chilled fresh water in various open or closed loop applications, including hydronic heating, domestic hot water recirculation, hydro-air heating/cooling, heat recovery units, water source heat pumps, drain-down open loop solar systems, and potable water applications. Please read this manual thoroughly before installation and operation.
2. Safety Information
YAMBIRO: Kukundikana kutevedzera mirairo iyi yekuchengetedza kunogona kukonzera kukuvara kwakanyanya kana kukuvara kwepfuma.
- Gara uchibvisa magetsi usati wagadzirisa pombi.
- Kuisa uye kusevha kunofanirwa kuitwa chete nevashandi vanokwanisa.
- Ita shuwa kuti kubatanidza kwemagetsi kunoenderana nemakodhi emunharaunda nemitemo.
- Do not operate the pump without water flowing through it, as this can cause damage.
- The pump operates at 115 Volts. Exercise caution to prevent electrical shock.
- The pump can become hot during operation. Avoid direct contact with the pump housing.
- Pfeka yakakodzera midziyo yekudzivirira yemunhu (PPE) panguva yekuisa uye kugadzirisa.
3. Chigadzirwa Pamusoroview
The Taco 006-B4 is a compact and efficient bronze circulator pump designed for reliable performance in various water circulation systems. Its unique design features a replaceable cartridge containing all moving parts, simplifying service and extending product life.
Zvinokosha:
- Bronze construction for corrosion resistance.
- Standard high capacity output with a compact design.
- Quiet and efficient operation.
- Direct drive motor with low power consumption (0.025 HP).
- Unique replaceable cartridge design for easy field service.
- Self-lubricating, requiring no mechanical seal and minimal maintenance.
- Suitable for potable water applications.

Figure 1: Taco 006-B4 Bronze Circulator Pump. This image shows the compact design of the circulator pump with its bronze housing and electrical connection box.
4. Setup uye Kuiswa
Proper installation is crucial for the optimal performance and longevity of your circulator pump. It is highly recommended that installation be performed by a qualified plumber or HVAC technician.
4.1 Pre-Instalation Checks
- Verify that the pump model (006-B4) is suitable for your application.
- Ensure the power supply matches the pump's requirements (115 Volts AC/DC).
- Confirm that the piping system is clean and free of debris.
- Have all necessary tools and materials, including appropriate fittings for 3/4-inch sweat connections.
4.2 Mounting and Piping
- Choose a location that allows for easy access for future servicing and provides adequate ventilation.
- Mount the pump securely in the piping system. The pump is designed for 3/4-inch sweat connections. Ensure proper soldering techniques are used to prevent leaks.
- Ensure the pump is installed with the motor shaft in a horizontal position to ensure proper lubrication and operation.
- Install isolation valves on both sides of the pump to facilitate future maintenance without draining the entire system.
- Fill the system with water and purge all air before operating the pump.
4.3 Kubatanidzwa kweMagetsi
- Ensure the main power supply is OFF before making any electrical connections.
- Connect the pump to a dedicated 115 Volt AC/DC circuit, protected by a fuse or circuit breaker as required by local electrical codes.
- Follow the wiring diagram provided with the pump or consult a qualified electrician.
- Ita shuwa kuti zvese zvinongedzo zvakasimba uye zvakachengeteka.
5. Kushanda
5.1 Kutanga Kutanga
- After installation and filling the system, ensure all air has been purged from the piping.
- Restore power to the pump. The pump should start operating quietly.
- Tarisa kana paine kudonha kwemvura panosangana ma connections.
- Monitor the system for proper circulation and temperature distribution.
5.2 Kujairika Kushanda
- The Taco 006-B4 operates with a flow range of 0-10 GPM and a head range of 0-9 feet.
- It is designed to handle fluid temperatures between 40°F (4°C) and 220°F (104°C).
- The maximum working pressure for this pump is 125 psi.
- The pump's 0.025 horsepower motor ensures efficient circulation with low power consumption.
- The pump is self-lubricating and does not require external lubrication.
6. Kuchengeta
The Taco 006-B4 circulator pump is designed for maintenance-free operation due to its self-lubricating properties and unique replaceable cartridge design.
6.1 Routine Checks
- Periodically inspect the pump and piping for any signs of leaks.
- Listen for any unusual noises during operation, which could indicate a problem.
- Ensure the pump is not running dry. Operating the pump without water will cause damage and is not covered under warranty. If the water supply to the house is turned off, ensure the pump is also unplugged or powered down.
6.2 Cartridge Replacement
The unique replaceable cartridge contains all the moving parts of the circulator. If the pump requires service beyond simple checks, the cartridge can be replaced, effectively renewing the pump's internal components. Refer to the specific cartridge replacement instructions provided by Taco or consult a qualified technician.
- YAMBIRO: Disconnect all power to the pump before attempting any service.
- Close the isolation valves on both sides of the pump.
- Drain the water from the pump section.
- Follow the manufacturer's instructions for removing and replacing the cartridge assembly.
- After replacement, reopen isolation valves, refill the system, purge air, and restore power.
7. Kugadzirisa matambudziko
This section provides solutions to common issues you might encounter with your Taco 006-B4 circulator pump. For problems not listed here, or if solutions do not resolve the issue, contact a qualified technician.
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Pombi haimhanye | No power; tripped circuit breaker; faulty wiring; seized motor. | Check power supply and circuit breaker. Verify wiring connections. If motor is seized, consider cartridge replacement or professional service. |
| Pombi inomhanya asi hapana kutenderera kweropa | Air in system; closed isolation valves; clogged impeller; incorrect rotation. | Purge air from the system. Ensure isolation valves are fully open. Inspect impeller for obstructions (requires professional service). Verify correct motor rotation if applicable. |
| Ruzha rusina kujairika kana kudedera | Air in system; cavitation; worn bearings (in cartridge); debris in pump. | Purge air from the system. Ensure adequate water flow to prevent cavitation. If noise persists, consider cartridge replacement. |
| Pump is hot to the touch | Normal operation; running dry; restricted flow; motor overload. | Some heat is normal. Ensure pump is not running dry. Check for restricted flow in piping. If excessively hot, disconnect power and seek professional advice. |
| Inodonha pazvibatanidza | Improperly sealed connections; damaged fittings. | Tighten connections. If leaks persist, drain system and re-seal or replace fittings. |
8. Zvinotsanangurwa
| Model Number | 006-B4 |
| Kukura Kwekubatanidza | 3/4-Inch Sweat |
| Material | Bronze (Housing), Cast Iron (Motor Casing) |
| Kuyerera Range | 0-10 GPM (Gallons Per Minute) |
| Musoro Range | 0-9 tsoka |
| Minimum Fluid Temperature | 40°F (4°C) |
| Maximum Fluid Temperature | 220°F (104°C) |
| Maximum Working Pressure | 125 psi |
| Voltage | 115 Volts |
| Simba Source | AC/DC |
| Motor Horsepower | 0.025 HP (hafu HP) |
| Item Weight | 4.41 makirogiramu (2 kg) |
| Product Dimensions | 5 x 4 x 7 inches (12.7 x 10.2 x 17.8 cm) |
9. Warranty uye Tsigiro
For detailed warranty information, please refer to the warranty card included with your product packaging or visit the official Taco website. If you require technical support, have questions about installation, or need assistance with troubleshooting, please contact Taco customer service or your authorized dealer.
Mugadziri: Iyo kambani Taco, Inc.
Websaiti: www.tacomfort.com