Welcome to your APC Back-UPS Pro 1500VA 230V Power Saving Uninterruptible Power Supply. This manual provides essential information for the safe and efficient operation of your UPS, designed to protect your electronic equipment from power outages, surges, and fluctuations. Please read this manual thoroughly before installation and use.
Chengetedzo Yekuchengetedza
- Electrical Shock Hazard: UPS iyi ine njodzitages. Usaedze kupatsanura chivako. Kugadzirisa kunofanira kuitwa chete nevashandi vane hunyanzvi.
- Nzvimbo Yakakodzera: Always connect the UPS to a grounded outlet. Do not remove the grounding prong from the power cord.
- Indoor Use Chete: This product is intended for indoor use only. Do not install the UPS in direct sunlight, near heat sources, or in areas with excessive moisture.
- Kufefetedza Ensure adequate airflow around the UPS. Do not block ventilation openings.
- Kuchengetedzwa kweBhatiri: Batteries can present a risk of electrical shock and high short-circuit current. Observe all precautions when replacing batteries. Use only APC-approved replacement batteries (RBC154).
- Overload Protection: Do not overload the UPS. Ensure the total power draw of connected equipment does not exceed the UPS's capacity.
Package Zviri mukati
Tarisa kuti zvinhu zvese zvakanyorwa pazasi zvinosanganisirwa mupakeji yako:
- APC Back-UPS Pro 1500VA 230V UPS Unit
- Mushandisi Chinyorwa (gwaro iri)
- Power Cord
- USB Kukurukurirana Cable
Product Overview
The APC Back-UPS Pro 1500VA 230V is a tower form factor UPS providing reliable battery backup and surge protection for your critical electronic equipment.
Front Panel Features

Mberi view of the APC Back-UPS Pro 1500VA unit, showing the LCD display and control buttons.
- Chiratidziro cheLCD: Provides real-time status information including input/output voltage, load level, battery charge, and estimated runtime.
- Bhatani reSimba: Turns the UPS unit on or off.
- Ratidza Bhatani: Cycles through various display screens to show different operational parameters.
- Mute/Setup Button: Mutes audible alarms or enters setup mode for configuration.
- USB-A and USB-C Charging Ports: Conveniently located for charging mobile devices.
Rear Panel Features

Rear view of the APC Back-UPS Pro 1500VA unit, showing the power outlets, data ports, and main power input.
- Nzvimbo Dzekuchengetedza Bhatiri & Nzvimbo Dzekubuda Dzinodzivirirwa: Ipa simba kubva kubhatiri panguva yekuvhimatages and protect against surges. Connect critical equipment here.
- Surge chete Zvitoro: Provide surge protection only. Connect non-critical equipment here.
- Main Power Input: Connects the UPS to the wall outlet.
- Circuit Remake: Provides overload protection for the UPS. Press to reset if tripped.
- USB Kukurukurirana Port: Inobatanidza UPS nekombuta yesoftware yekugadzirisa magetsi.
- Ethernet/Network Protection Ports: Protects network connections from surges.
Gadzirira
- Vhura uye ongorora: Carefully unpack the UPS and all accessories. Inspect for any shipping damage.
- Batanidza bhatiri remukati: The UPS battery may be disconnected for shipping. Refer to the battery compartment access panel (usually at the bottom or rear) and connect the battery terminals as indicated.
- Position the UPS: Place the UPS in a location with adequate ventilation, away from direct sunlight, excessive heat, or moisture. Ensure the front and rear vents are unobstructed.
- Batanidza kuWall Outlet: Plug the UPS power cord directly into a grounded 230V wall outlet. Avoid using extension cords or surge protectors with the UPS input.
- Chekutanga Charge: Allow the UPS to charge for at least 24 hours before connecting any equipment to ensure maximum battery runtime. The battery indicator on the LCD will show charging status.
- Batanidza Midziyo:
- Plug critical equipment (e.g., computer, monitor, router) into the Kuchengetedza Bhatiri & Kukwira Kwakachengetedzwa outlets.
- Plug non-critical equipment (e.g., printer, scanner) into the Surge chete outlets.
- Batanidza Mitsetse yeData (Sarudzo): Connect your USB communication cable from the UPS to your computer to enable power management software features. Connect network cables to the Ethernet protection ports if desired.
Operating Instruction
Kubatidza/Kudzima
- Kubatidza: Press and hold the Power button on the front panel until you hear a beep and the LCD display illuminates.
- Kudzima: Press and hold the Power button until the LCD display turns off.
LCD Ratidza Navigation
- Press the Display button repeatedly to cycle through various information screens, including: Input Voltage, Kubuda Voltage, Load in Watts, Load in VA, Battery Charge Percentage, and Estimated Runtime.
Alarm Management
- Munguva yesimba outage, the UPS will emit an audible alarm. Press the Mute/Setup button briefly to temporarily silence the alarm.
- To permanently disable or enable alarms, refer to the detailed instructions in the full user manual or power management software.
Maintenance
Kutsiviwa kwebhatiri
- The typical battery life is 3-5 years, depending on usage and environmental conditions.
- When the battery needs replacement, the UPS will indicate this on the LCD display and may emit an alarm.
- Use only genuine APC replacement battery cartridges (RBC154) to ensure optimal performance and safety. Refer to the full user manual for detailed battery replacement instructions.
Kuchenesa
- Regularly clean the exterior of the UPS with a dry cloth.
- Iva nechokwadi chekuti nzvimbo dzinopinda mhepo hadzina guruva kana marara kudzivirira kupisa zvakanyanya.
Storage
- If storing the UPS for an extended period, ensure the battery is fully charged.
- Store the unit in a cool, dry location with adequate ventilation.
- Recharge the battery every 3-6 months to prevent permanent damage.
Kugadzirisa matambudziko
Pazasi pane zvinowanzoitika uye mhinduro dzadzo:
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| UPS haizoshanduke | Battery disconnected or low charge; UPS not plugged in. | Ensure battery is connected. Plug UPS into a live wall outlet and allow to charge. |
| Nguva pfupi yebhatiri | Overloaded; battery old or not fully charged. | Reduce connected load. Allow battery to charge for 24 hours. Replace battery if old. |
| UPS emits continuous alarm | On battery mode; overload; battery fault. | Check power source. Reduce load. Check battery status on LCD. |
| Hapana simba kuzvitoro | UPS off; circuit breaker tripped; battery fault. | Turn UPS on. Reset circuit breaker. Check battery status. |
Zvinotaurwa Nezvehunyanzvi
| Feature | Tsanangudzo |
|---|---|
| Model Number | BR1500GI |
| Product Dimensions | 4.41 x 15.04 x 11.89 inches |
| Item Weight | 27.9 makirogiramu |
| Voltage | 230 Volts |
| Mabhatiri | Mabhatiri maviri e12V anodiwa (akabatanidzwa) |
| Battery Cell Kuumbwa | Lead Acid |
| Color | Nhema |
| Material | Metal |
| Fomu Factor | Tower |
Warranty uye Support
For detailed warranty information, product registration, and technical support, please visit the official APC by Schneider Electric websaiti kana kubata dhipatimendi ravo rebasa revatengi. Chengetedza risiti yako yekutenga sehumbowo hwekutenga kune chero vimbiso yewaranti.
Unogona kuwana zvimwe zviwanikwa uye ruzivo rwekuonana pa APC by Schneider Electric Store on Amazon.