1. Nhanganyaya
This manual provides essential information for the installation, operation, and maintenance of the Johnson Controls TEC2203-3 Non-Programmable Thermostat. This device is designed for controlling heating and cooling systems with 2 Heat and 2 Cool stages, and features a 1SPDFAN (Single Pole Double Throw Fan) control. It serves as a reliable replacement thermostat for compatible HVAC systems.
2. Chigadzirwa Pamusoroview
2.1 Mamiriro Akakosha
- Non-Programmable operation for straightforward temperature control.
- Supports 2 Heat and 2 Cool stages for versatile HVAC system compatibility.
- Integrated 1SPDFAN control.
- Clear digital display for room temperature.
2.2 Zvikamu uye Kuratidzwa
The TEC2203-3 thermostat features a user-friendly interface with a digital display and intuitive buttons for control. Refer to the image below for a visual guide to the thermostat's components.

Mufananidzo 1: Mberi view of the Johnson Controls TEC2203-3 Thermostat. The image shows the white rectangular thermostat unit with a central digital display indicating "Room Temp 70.0 °F". Below the display are control buttons: "YES", "NO", "MENU", a down arrow, and an up arrow. Indicators for "SCROLL", "FAN", "HEAT", and "COOL" are also visible.
The display shows the current room temperature. Indicators for HEAT and COOL illuminate when the respective modes are active. The FAN indicator shows fan operation. Buttons include:
- YES / NO: Used for confirming or canceling selections in menu options.
- MENU: Accesses system settings and operational modes.
- Up Arrow / Down Arrow: Adjusts temperature setpoints and navigates menu options.
3. Kuiswa
Installation of the Johnson Controls TEC2203-3 Thermostat should be performed by a qualified HVAC technician. Incorrect installation can lead to system malfunction, property damage, or personal injury. Always ensure power to the HVAC system is turned off at the circuit breaker before beginning any installation work.
3.1 Chengetedzo Yekuchengetedza
- Disconnect all power to the heating and cooling system before installation.
- Follow all local electrical codes and ordinances.
- Ensure wiring connections are secure and correct according to the wiring diagram provided with the product packaging (not included in this manual).
4. Operating Instructions
The TEC2203-3 is a non-programmable thermostat, meaning it maintains a set temperature until manually changed.
4.1 Kuisa Iyo Tembiricha
- Chiratidziro chinoratidza tembiricha yekamuri iripo.
- Press the Museve Wekumusoro or Museve Wepasi button to adjust the desired temperature setpoint.
- The new setpoint will flash briefly and then be saved. The system will then work to reach and maintain this temperature.
4.2 Changing System Mode (Heat/Cool/Off)
- Press the MENU bhatani.
- Shandisa iyo Museve Wekumusoro or Museve Wepasi to navigate through the available system modes (e.g., HEAT, COOL, OFF).
- Press EHE kusarudza modhi yaunoda.
- The corresponding indicator (HEAT or COOL) will illuminate when active.
4.3 Kushanda kweFani
The fan can typically be set to AUTO (runs only when heating or cooling) or ON (runs continuously).
- Press the MENU bhatani.
- Navigate to the fan settings using the Museve Wekumusoro or Museve Wepasi.
- Press EHE kusarudza yaunoda fan mode.
5. Kuchengeta
The Johnson Controls TEC2203-3 Thermostat requires minimal maintenance to ensure optimal performance.
- Kuchenesa: Nguva nenguva pukuta kunze kwe thermostat nekanyoro, damp jira. Usashandise abrasive cleaners kana solvents.
- Kuyerera kwemhepo: Ita shuwa kuti mavhavha e thermostat haana kuvharwa neguruva kana marara, sezvo izvi zvichigona kukanganisa kunyatsonzwa tembiricha.
- Professional Check-ups: It is recommended to have your entire HVAC system, including the thermostat, inspected by a professional technician annually.
6. Kugadzirisa matambudziko
If you experience issues with your TEC2203-3 thermostat, consider the following common troubleshooting steps:
- Hapana Chiratidziro/Simba: Check the circuit breaker for your HVAC system. Ensure the thermostat is properly seated on its base.
- Kuverenga Kusiri Kodzero Ensure the thermostat's vents are clear of obstructions. Avoid placing the thermostat near heat sources (lamps, direct sunlight) or drafts.
- Sistimu isingapindure: Verify the system mode (HEAT/COOL/OFF) is correctly selected. Check if the temperature setpoint is above (for heat) or below (for cool) the current room temperature.
- Fan Haisi Kushanda: Check the fan mode setting (AUTO/ON). If set to AUTO, the fan will only run when heating or cooling is active.
Kana matambudziko aramba aripo mushure mekuedza nhanho idzi, bata nyanzvi yeHVAC kuti ubatsirwe.
7. Zvinotsanangurwa
| Feature | Detail |
|---|---|
| Model | TEC2203-3 |
| Brand | Johnson Controls |
| Control Type | Isiri-Inogadziriswa Thermostat |
| Stages | 2 Kupisa / 2 Kutonhorera |
| Fan Control | 1SPDFAN |
| Item Weight | 1 Pondo |
| ASIN | B004H2XCMU |
8. Warranty uye Tsigiro
For specific warranty information and technical support regarding your Johnson Controls TEC2203-3 Thermostat, please refer to the documentation included with your purchase or contact Johnson Controls directly. Warranty terms and support options may vary based on region and purchase location.