1. Chigadzirwa Pamusoroview

The Modine 32161 Horizontal Concentric Venting Kit is designed for use with Modine gas-fired unit heaters. This kit facilitates the proper arrangement of tubing for both exhaust and combustion air intake in a concentric configuration.

Zvigadzirwa Zvikamu

  • 1 x Concentric Vent Kit Adapter Box
  • 1 x Vent Pipe Terminal
  • 1 x Combustion Air Pipe Terminal
Modine 32161 Horizontal Concentric Venting Kit components: a large rectangular adapter box with two circular openings, a smaller cylindrical vent pipe terminal, and a metal ring.

Image: The Modine 32161 Horizontal Concentric Venting Kit, showing the adapter box, vent pipe terminal, and combustion air pipe terminal.

2. Kuenderana Kwechigadzirwa

This venting kit is compatible with the following Modine gas-fired unit heater models:

  • Modine HDS30 Unit Heaters
  • Modine HDS45 Unit Heaters
  • Modine HDS60 Unit Heaters
  • Modine HDS75 Unit Heaters
  • Modine HDC60 Unit Heaters
  • Modine HDC75 Unit Heaters
  • Modine HDC100 Unit Heaters
  • Modine HDC125 Unit Heaters
  • Modine PTS150 Unit Heaters
  • Modine PTS175 Unit Heaters
  • Modine PTS200 Unit Heaters
  • Modine BTS150 Unit Heaters
  • Modine BTS175 Unit Heaters
  • Modine BTS200 Unit Heaters

3. Nhungamiro dzeKugadzirisa uye Kuisa

Installation of the Modine 32161 Horizontal Concentric Venting Kit should be performed by a qualified professional in accordance with all local and national building codes, as well as the specific instructions provided with your Modine unit heater.

Mafungiro akakosha ekuiswa:

  • Ventilation Zvinodiwa: Ensure adequate clearance and proper routing for both exhaust gases and fresh air intake.
  • Secure Connections: All connections must be sealed and secured to prevent leaks and ensure efficient operation.
  • Kurongeka Kwakakodzera: The concentric vent kit adapter box must be correctly aligned with the unit heater's venting ports.
  • Terminal Placement: Position the vent and combustion air pipe terminals to prevent obstruction and ensure proper airflow.
  • Kuongorora: After installation, thoroughly inspect all connections and components for proper fit and function.

4. Kuchengeta

Regular maintenance of your venting system is crucial for safe and efficient operation of your Modine unit heater. Perform visual inspections periodically and address any issues promptly.

Mabasa Anokurudzirwa Ekugadzirisa:

  • Visual Inspection: Annually inspect the entire venting system for signs of corrosion, damage, or blockages.
  • Kuchenesa Chiteshi: Ensure the vent and combustion air pipe terminals are free from debris, leaves, snow, or insect nests.
  • Chisimbiso Kutendeseka: Check all seals and connections for any signs of deterioration or leaks.
  • Structural Support: Verify that the venting system is adequately supported and securely fastened.

If any issues are identified, consult a qualified service technician for repair or replacement.

5. Kugadzirisa matambudziko

This section provides general guidance for common issues related to the venting system. For complex problems or issues with the unit heater itself, refer to the heater's specific manual or contact a qualified technician.

Matambudziko Anowanikwa uye Mhinduro:

  • Reduced Heater Performance:
    Inogona Kukonzera: Partially blocked vent or air intake.
    Solution: Inspect and clear any obstructions from the vent and combustion air pipe terminals.
  • Unusual hwema:
    Inogona Kukonzera: Exhaust gas leakage.
    Solution: Immediately shut down the unit heater. Inspect all vent connections for leaks and ensure they are properly sealed. Contact a professional for repair.
  • Visible Damage to Venting:
    Inogona Kukonzera: Physical impact or corrosion.
    Solution: Do not operate the unit heater if the venting system is visibly damaged. Replace damaged components immediately.

6. Zvinotsanangurwa

AttributeValue
Model Number32161
Item Weight4 Pondo
MugadziriModine Parts
Kutanga KuwanikwaChivabvu 15, 2012

7. Warranty uye Tsigiro

For information regarding the warranty of the Modine 32161 Horizontal Concentric Venting Kit, please refer to the documentation provided with your Modine unit heater or contact Modine Manufacturing directly. Modine provides comprehensive support for its products.

For technical assistance, replacement parts, or service inquiries, please visit the official Modine website or contact their customer service department. Always provide your product model number (32161) and any relevant serial numbers when seeking support.

Related Documents - 32161

Preview Modine Concentric and Two-Pipe Venting Installation and Service Manual
Comprehensive installation and service manual for Modine concentric and two-pipe venting systems, including models DFS, DBS, DCS, IFS, IBS, ICS, PSH, and BSH. Covers safety warnings, general instructions, and specific installation procedures for venting gas-fired heating equipment.
Preview Modine 6-466.1: Kuisa & Kugadzirisa Masisitimu Emhepo Asina Kusviba Anosvika 3-Inch (Zvishandiso zveGas zveChikamu III)
Gwaro rakadzama rekuisa nekugadzirisa masisitimu eModine e6-466.1 ane madziro matatu esimbi isina tsvina. Rinovhara kuchengetedzeka, kuungana kwakakodzera, kubata condensate, uye rutsigiro rwemidziyo yegesi yeCategory III.
Preview Modine Gasi-Yakapisa Yuniti Heaters: HDS, HDC, PTX, BTX - Catalog uye Zvinotsanangurwa
Gwaro iri rinopa ruzivo rwakadzama pamusoro peModine's Gasi-Yakapisa Yakapatsanurwa Inopisa Unit Heaters (HDS, HDC) uye Dual Rated Venting Unit Heaters (PTX, BTX). Inovhara magadzirirwo edhizaini, data rekuita, maitiro ekusarudza mayuniti, dimensional data, zvakatemwa, uye zviripo zvekushandisa kune idzi HVAC mhinduro.
Preview Modine EWH Electric Wall Heater Installation and Service Manual
Comprehensive installation and service manual for the Modine EWH Electric Wall Heater, detailing safety, installation, maintenance, troubleshooting, and technical specifications for qualified professionals.
Preview Modine MDB/MRB, QDB/QRB Make-Up Air Units: Bhuku reKuisa uye Basa
Bhuku rekushandisa rakakwana rekuisa uye rebasa reModine MDB/MRB neQDB/QRB. Rinovhara kuchengetedzeka, kuisa, kushanda, kugadzirisa, uye kugadzirisa matambudziko ekushandiswa kweHVAC mumaindasitiri.
Preview Bhuku rekushandisa Modine HD & HDB Gas-Fired Unit Heaters
Bhuku rekushandisa rakakwana rekuisa uye rebasa reModine HD neHDB series gas-fired unit heaters. Rinovhara kuchengetedzeka, kuisa, kuburitsa mweya, kubatana negasi, magetsi, mashandiro, uye kugadzirisa matambudziko.