HACH 145300

HACH Total Hardness Test Kit, Model 5-B

Muenzaniso Nhamba: 145300

1. Nhanganyaya

The HACH Total Hardness Test Kit, Model 5-B, provides a simple and economical method for determining water hardness through drop count titration. This kit is designed for field and laboratory use, offering reliable measurements of total hardness expressed as CaCO₃. The method utilizes a drop count titration with a range of 1-30 grains per gallon (gpg), with each drop of titrant equivalent to 1 gpg. The kit contains sufficient reagents for approximately 100 tests.

2. Safety Information

WARNING: This kit contains chemicals that may be harmful if misused. Carefully read the label on each container before use.

  • Always wear appropriate personal protective equipment, such as safety glasses, to protect eyes from chemical splashes.
  • Avoid direct contact of reagents with skin and clothing. In case of contact, rinse immediately with plenty of water.
  • Do not ingest any reagents. If ingested, seek immediate medical attention.
  • Wash hands thoroughly with soap and water after handling chemicals.
  • Dispose of all chemical waste according to local environmental regulations.

3. Kit Zvikamu

The HACH Total Hardness Test Kit, Model 5-B, includes the following items:

  • Titrant Solution, Hardness 3, 0.015 M EDTA (100 mL bottle with dropper)
  • UniVer® 3 Hardness Reagent (powder, 26.3 g bottle)
  • Measuring Tube (Cat. No. 438-00)
  • Square Mixing Bottle (Cat. No. 439-06)
  • Measuring Scoop (for UniVer® 3 Hardness Reagent)
Hach Total Hardness Test Kit, Model 5-B components
Image 1: The Hach Total Hardness Test Kit, Model 5-B, showing the titrant bottle, UniVer® 3 reagent, measuring tube, square mixing bottle, and measuring scoop.

4. Setup

Before beginning the test, ensure all components are clean and readily accessible. Work in a well-lit area.

  1. Unpack all kit components and verify their presence against the list above.
  2. Rinse the measuring tube and square mixing bottle thoroughly with the water sample to be tested, then discard the rinse water. This prevents contamination from previous tests or tap water.

5. Operating Instructions: Drop Count Titration

Follow these steps to perform a total hardness test:

  1. Unganidza Sample: Fill the measuring tube (Cat. No. 438-00) to the 25 mL mark with the water sample to tested.
  2. Transfer Sample: Pour the 25 mL water sample from the measuring tube into the square mixing bottle (Cat. No. 439-06).
  3. Wedzera Reagent: Using the provided measuring scoop, add one level scoop of UniVer® 3 Hardness Reagent (Cat. No. 511-00) to the square mixing bottle. Cap the bottle and swirl gently to mix until the powder dissolves completely. The sample should turn a red or pink color if hardness is present. If the sample turns blue immediately, the water is very soft (less than 1 gpg).
  4. Titrate Sample: Hold the Titrant Solution bottle (0.015 M EDTA) vertically and add the solution drop by drop to the sample in the square mixing bottle. After each drop, cap the bottle and swirl to mix thoroughly.
  5. Observe Color Change: Continue adding drops and swirling until the color of the sample changes from red/pink to a clear blue. This is the endpoint of the titration.
  6. Count Drops: Record the total number of drops of Titrant Solution added to achieve the color change.

Kuverenga Each drop of Titrant Solution corresponds to 1 grain per gallon (gpg) of total hardness. Therefore, the number of drops equals the total hardness of your water sample in gpg.

Shanduko: To convert grains per gallon (gpg) to milligrams per liter (mg/L) as CaCO₃, multiply the gpg value by 17.1. (1 gpg = 17.1 mg/L CaCO₃).

Person conducting a water test outdoors
Image 2: A person in protective gear conducting a water quality test in an outdoor industrial setting, demonstrating typical application environments for Hach products.

6. Kuturikira Migumisiro

The total number of drops of Titrant Solution required to change the sample color from red/pink to blue directly indicates the water hardness in grains per gallon (gpg). For example, if 10 drops were required, the water hardness is 10 gpg.

Understanding your water hardness is crucial for various applications, including water treatment, appliance maintenance, and industrial processes.

Scientist in a lab coat using a Hach device
Image 3: A scientist in a lab coat and safety glasses operating a Hach water analysis device in a laboratory setting, highlighting the professional use of Hach equipment.

7. Kuchengeta

Proper maintenance ensures the longevity and accuracy of your test kit.

  • Kuchenesa: After each use, thoroughly rinse the measuring tube, square mixing bottle, and scoop with distilled or deionized water. Allow them to air dry completely before storage.
  • Kuchengeta: Store all reagents in their original containers, tightly capped, in a cool, dark place away from direct sunlight and extreme temperatures. Ensure the Titrant Solution bottle is stored upright.
  • Kupera kweReagent: Check the expiration dates on the reagent bottles. Expired reagents may lead to inaccurate results. Replace reagents as needed.

8. Kugadzirisa matambudziko

If you encounter issues during testing, consider the following common problems and solutions:

  • No Color Change to Red/Pink: Kana iyo sample does not turn red/pink after adding UniVer® 3 Hardness Reagent, the water may be extremely soft (less than 1 gpg) or the reagent may be expired. Try a known hard water sample to verify reagent activity.
  • Zvisina Kurongeka:
    • Ensure all glassware is clean and free from contamination.
    • Verify that reagents are not expired.
    • Ensure accurate measurement of the water sample (25 mL).
    • Add titrant drops consistently and swirl thoroughly after each drop.
  • Difficulty Seeing Color Change: Perform the test under good lighting conditions. A white background can help make the color change more apparent.

9. Zvinotsanangurwa

TsanangudzoDetail
Model Number145300
ParameterHardness, Total - As CaCO₃
Method NameDrop Count Titration / EDTA-bulk powder
Range1-30 gpg (grains per gallon)
Approximate Tests100
Package Dimensions5.04 x 2.68 x 2.6 inches
Item Weight8.96 ounces
MugadziriHACH COMPANY

10. Warranty uye Tsigiro

HACH products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official HACH website. For technical support, product inquiries, or to purchase replacement reagents, please contact HACH customer service or visit the HACH store online.

HACH Store: https://www.amazon.com/stores/Hach/page/F31EE231-E533-4E96-B7EB-49EC9C17D676

Related Documents - 145300

Preview Kiti Yekuyedza yeHACH Kuoma (Huwandu neCalcium) HA-4P MG/L (145701) - Mirayiridzo uye Magadzirirwo
Mirayiridzo yakadzama uye zvirevo zveHACH Hardness (Total and Calcium) Test Kit, Model HA-4P MG/L (145701). Dzidza maitiro ekuita bvunzo dzetotal necalcium hardness, kunzwisisa kupindira, uye kuodha zvinhu zvinotsiva.
Preview HACH EZ4041 Total Hardness Analyser - Kuongorora Hunhu hweMvura
Tsvaga HACH EZ4041 Total Hardness Analyzer, iyo online, otomatiki colorimetric titrator yakagadzirirwa kutarisa mvura mumaindasitiri uye nharaunda. Zvinhu zvinosanganisira kuyera kwakasiyana-siyana, mabasa akangwara otomatiki, nzira dzinochinjika dzetitration, uye kugona kwakawanda kwekuongorora rwizi.
Preview Nzira dzeHach Dzinotsvaga Gwaro Rekukurumidza: Zvishandiso Zvekuongorora Makemikari uye Zvigadzirisi
Gwaro rakakwana renzira dzekuongorora makemikari dzaHach, kutsanangura maparamita ekuyedza, kubvumidzwa kweEPA, kuenderana kwemidziyo, uye nhamba dzezvigadzirwa zvekuyedza hunhu hwemvura.
Preview Total Nitrogen Persulfate Digestion Method 10071 for Water and Wastewater Analysis
Comprehensive guide for performing Total Nitrogen analysis using the Hach Persulfate Digestion Method 10071 with Test 'N Tube™ Vials. Covers instrument setup, sample preparation, digestion procedures, measurement, interferences, and accuracy checks for water and wastewater testing.
Preview Maitiro ekugadzirisa Hach DR-3000 yeAccu-TEST COD Vials
Mirayiridzo nemasevhisi ekugadzirisa Hach DR-3000 spectrophotometer kana colorimeter kuti ushandise Bioscience, Inc.'s accu-TEST COD vials. Inosanganisira rutsigiro uye ruzivo rwebasa rekugadzirisa kubva kuBioscience, Inc.
Preview Nzira yeHach NitraVer 5 Nitrate High Range 8039: Gwaro rekuongorora
Gwaro rakakwana rekuita ongororo yepamusoro yenitrate (0-30.0 mg/L NO3--N) uchishandisa Hach's NitraVer 5 reagent ine Powder Pillows kana AccuVac Ampuls (Nzira 8039).