MARS 67915

MARS 67915 Chinotsiva Furnace: Bhuku rekushandisa nekuisa

Model: 67915 | Brand: MARS

1. Nhanganyaya

This manual provides essential information for the safe and correct installation, operation, and maintenance of the MARS 67915 Furnace Replacement Ignitor. This hot surface ignitor is designed to replace various original equipment manufacturer (OEM) ignitors in residential and commercial furnace systems. Please read this manual thoroughly before attempting any installation or service.

2. Safety Information

YAMBIRO: Kuisa, kugadzirisa, kushandura, sevhisi, kana kugadzirisa zvisizvo zvinogona kukonzera kukanganisa, kukuvara, kana kufa. Verenga mirairo yekuisa, kushanda, uye kugadzirisa zvakakwana usati waisa kana kusevhisa mudziyo uyu.

3. Chigadzirwa Pamusoroview uye Features

The MARS 67915 is a high-quality hot surface ignitor designed for reliable ignition in various furnace applications. It features a durable construction and is engineered to meet or exceed OEM specifications.

MARS 67915 Furnace Replacement Ignitor

Mufananidzo 1: MARS 67915 Furnace Replacement Ignitor. This image displays the ignitor unit, which consists of a U-shaped black heating element attached to a ceramic base, with two brown wires and multiple white wires extending from the base, bundled together and terminating in a white connector.

Zvinokosha:

4. Kugarisana

The MARS 67915 ignitor is designed as a direct replacement for the following models:

It is also used in specific Clare and ICP Equipment Models including: HEHE100S, HFHF100S, HEHF100, HEHF100S, HEHF100B, HEHF50, HEHF50B, HEHF80, HEHF80B, HEMB100, HEMB100B, HEMB110, HEMB110B, HEMB120, HEMB120B, HEMB130, HEMB130B, HEMB40, HEMB40B, HEMB50, HEMB50B, HEMB60, HEMB60B, HEMB70, HEMB70B, HEMB80, HEMB80B, HEMB90, HEMB90B.

Always verify compatibility with your specific furnace model and manufacturer's instructions before replacement.

5. Installation Instructions

ZVINOKOSHA: Installation should only be performed by a qualified HVAC technician. Failure to follow these instructions can result in property damage, personal injury, or death.

  1. Chengetedzo Kutanga: Turn off all electrical power to the furnace at the main service panel. Close the manual gas shut-off valve to the furnace.
  2. Chinobatidza Kupinda: Locate and remove the furnace access panel(s) to expose the burner assembly and ignitor.
  3. Bvisa Ignitor Yekare: Carefully disconnect the wiring harness from the old ignitor. Note the routing of the wires.
  4. Bvisa Ignitor Yekare: Unscrew or unclip the old ignitor from its mounting bracket. Handle it gently as it may be fragile.
  5. Inspect Mounting: Examine the mounting bracket for any damage or corrosion. Clean if necessary.
  6. Isa Ignitor Itsva: Carefully mount the new MARS 67915 ignitor onto the bracket using the original hardware or suitable replacements. Ensure it is securely fastened and positioned correctly according to the furnace manufacturer's specifications. Avoid touching the black ignitor element.
  7. Batanidza Wiring: Connect the new ignitor's wiring harness to the furnace control board or existing wiring, ensuring a secure and correct connection. The MARS 67915 comes with 36-inch leads and a connector for direct replacement.
  8. Secure Panels: Replace all furnace access panels securely.
  9. Dzorera Simba neGasi: Open the manual gas shut-off valve. Restore electrical power to the furnace.
  10. Test Operation: Initiate a call for heat at the thermostat and observe the furnace's ignition sequence to ensure the new ignitor glows and ignites the gas burner properly.

6. Operating Principle

The MARS 67915 is a hot surface ignitor. When the furnace calls for heat, the control board sends voltage to the ignitor, causing its silicon carbide element to heat up rapidly to a very high temperature (typically over 1800°F or 980°C). Once the ignitor reaches its optimal temperature, the gas valve opens, allowing gas to flow over the hot ignitor, which then ignites the gas. After successful ignition, the ignitor typically de-energizes, and the flame sensor confirms the presence of a flame.

7. Kuchengeta

The MARS 67915 ignitor is a sealed component and does not require routine user maintenance. However, regular professional furnace maintenance is recommended to ensure optimal performance and longevity of all furnace components, including the ignitor.

8. Kugadzirisa matambudziko

If your furnace is not igniting, and you suspect the ignitor, consider the following common issues. Always ensure safety precautions are followed before any inspection.

For complex issues, it is highly recommended to contact a certified HVAC professional.

9. Zvinotsanangurwa

Mugadziri:MARS
Chikamu Nhamba:67915
Chinhu Weight:1 pound
Ruvara:Multicolor (referring to components)
Item Package Quantity:1
Inotungamira:36 inches with connector
ASIN:B00CD5ZPA0
Zuva Rokutanga Kuwanikwa:Chikumi 3, 2013

10. Warranty uye Tsigiro

Specific warranty details for the MARS 67915 ignitor are typically provided at the point of purchase or can be obtained directly from the manufacturer, MARS. Please retain your proof of purchase for warranty claims.

For technical support, product inquiries, or warranty service, please contact MARS customer service or your authorized MARS dealer.

Related Documents - 67915

Preview MARS HVAC/R Service & Installation Catalog
Explore the comprehensive MARS catalog for HVAC/R service and installation products. Find essential components like air conditioner mounting brackets, condenser pads, vent kits, disconnect boxes, and more, designed for professional installation and reliable performance.
Preview MARS 2025 Featured Products Guide: Motors, Components, Service & Installation
Explore the comprehensive MARS 2025 Featured Products Guide, showcasing a wide array of motors, components, and service & installation products for the HVAC/R market. Discover leading brands and innovative solutions.
Preview MARS SGF80S120D5S1A Single-StagRondedzero yeZvikamu zveFurnace yeGasi yeMamiriro Akawanda
Rondedzero yepamutemo yezvikamu zveMARS SGF80S120D5S1A Single-Stage Multi-Position Gas Furnace. Gwaro iri rinotsanangura zvikamu, mazita ezvikamu, uye huwandu hweSE Series 80% AFUE furnace.
Preview Kupinda muzvikamu zveMARS: Gwaro reHVAC/R Replacement Components
Gwaro rakazara kubva kuMARS rinopa rondedzero yezvigadzirwa zvevatengesi vanotanga basa rekutengesa zvinhu zvakawanda vari kupinda mumusika wezvinhu zvinotsiva zveHVAC/R, mota, uye zvigadzirwa zvebasa/kuisa. Inosanganisira mapoka ezvigadzirwa, nhamba dzezvikamu, uye tsananguro.
Preview MARS 24 (MW) Water-to-Water Series: Installation, Operation & Maintenance Manual
Comprehensive guide for the MARS 24 (MW) Water-to-Water Series, covering installation, operation, and maintenance procedures for commercial applications. Includes model nomenclature, safety warnings, refrigerant system servicing, physical data, and troubleshooting.
Preview Rondedzero yeZvikamu Zvekutsiva Makaseti eSirin'i eMARS uye Zvakaputika View
Rondedzero yakazara yezvikamu zvekutsiva uye yakaputika view madhayagiramu eMARS Comfort Aire Century Ceiling Cassette air conditioning units, kusanganisira mamodheru eB-VHP09CA-1, B-VHP12CA-1, B-VHP18CA-1, uye B-VHP24CA-1.