1. Chigadzirwa Pamusoroview
The Pedrollo Vortex Zxm1A/40 is a submersible electric pump designed for domestic drainage of wastewater, including water containing suspended solids up to 40 mm in diameter. This pump is engineered for straightforward installation and reliable automatic operation in fixed installations. It is suitable for applications requiring efficient removal of dirty water.

Mufananidzo 1: Pedrollo Vortex Zxm1A/40 Electric Submersible Pump. This image shows the complete pump unit, featuring a silver-colored motor housing, an orange handle, a float switch, and a blue pump body with an outlet port.
2. Safety Information
Read all safety warnings and instructions carefully before installing, operating, or performing maintenance on this product. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.
- Kuchengetedzwa Kwemagetsi: Always disconnect the pump from the power supply before handling, installing, or performing any maintenance. Ensure the power supply matches the pump's voltage requirements (220-240V). Use a ground fault circuit interrupter (GFCI) for all electrical connections.
- Kuchengetedzwa Kwemvura: Do not operate the pump in water containing flammable or explosive materials. Ensure the pump is fully submerged during operation to prevent overheating.
- Kubata: Never lift the pump by its power cable or float switch cable. Use the designated handle for transport and installation.
- Vana uye Zvipfuwo: Chengeta vana nezvipfuyo kure nepombi nenzvimbo yayo yekushandira.
- Vashandi Vanokwanisa: Installation and electrical connections should only be performed by qualified personnel in accordance with local regulations and standards.
3. Setup uye Kuiswa
3.1 Kusunungura
Carefully remove the pump from its packaging. Inspect the pump for any signs of damage that may have occurred during transit. Retain packaging materials for future storage or transport.
3.2 Kuiswa
- Place the pump on a stable, flat surface in the lowest part of the area to be drained.
- Ensure the pump is fully submerged in water during operation. The float switch requires sufficient space to move freely for automatic operation.
- Avoid placing the pump directly on soft mud or sand, which could clog the intake. A solid base or platform is recommended.
3.3 Hose Connection
- Connect a suitable discharge hose to the pump's outlet port. Ensure the connection is secure and watertight to prevent leaks.
- Route the discharge hose away from the area to be drained, ensuring it leads to an appropriate disposal point. Avoid kinks or sharp bends in the hose that could restrict flow.
3.4 Electrical Connection
- Tarisa kuti magetsi emagetsi voltage matches the pump's requirements (220-240V).
- Connect the pump to a properly grounded electrical outlet protected by a Ground Fault Circuit Interrupter (GFCI).
- Ensure the power cable is not stretched, pinched, or damaged. Keep the cable away from sharp objects and hot surfaces.
4. Operating Instructions
4.1 Kutanga Kutanga
- After installation, ensure the pump is fully submerged and the float switch can move freely.
- Plug the pump into the GFCI-protected electrical outlet.
- The pump will start automatically when the water level rises and activates the float switch. It will stop when the water level drops and deactivates the float switch.
4.2 Kujairika Kushanda
- Monitor the pump during its first few cycles to ensure proper function and drainage.
- The pump is designed for automatic operation. No manual intervention is typically required during normal use.
- Avoid running the pump dry, as this can cause damage. The float switch is designed to prevent dry running.
4.3 Kuvhara
To manually stop the pump, simply unplug it from the electrical outlet. For temporary cessation of automatic operation, secure the float switch in a position that prevents it from activating.
5. Kuchengeta
Regular maintenance ensures optimal performance and extends the lifespan of your pump. Always disconnect power before performing any maintenance.
5.1 Kuchenesa
- Periodically inspect the pump intake for debris, such as leaves, rags, or other solids, which could obstruct flow. Clear any blockages carefully.
- Check the float switch for free movement and ensure it is not fouled by debris.
- Rinse the pump with clean water after use in heavily soiled conditions to prevent buildup.
5.2 Kuchengeta
If the pump will not be used for an extended period, especially in freezing conditions:
- Disconnect power and remove the pump from the water.
- Drain all water from the pump and hose.
- Geza pombi zvakakwana.
- Chengeta pombi yacho munzvimbo yakaoma, isina chando.
6. Kugadzirisa matambudziko
Usati wabata rutsigiro, review zvinotevera zvinowanzoitika uye mhinduro:
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Pombi haina kutanga. | No power; Float switch not activated; Clogged impeller. | Check power connection and GFCI; Ensure water level is high enough to activate float switch; Disconnect power and clear impeller. |
| Pombi inomhanya asi hapana mvura inobuda kana kuti mvura inoyerera yakaderera. | Discharge hose kinked or blocked; Pump intake clogged; Air lock; Low water level. | Check and clear discharge hose; Disconnect power and clear pump intake; Briefly lift and lower pump to release air; Ensure pump is fully submerged. |
| Pump cycles on and off too frequently. | Float switch restricted; Water level fluctuating rapidly. | Check float switch for free movement; Ensure pump is placed in an area with stable water levels. |
7. Zvinotsanangurwa
| Feature | Detail |
|---|---|
| Model | Zxm1A/40 |
| Manufacturer Reference | PSG 48SDZE4AA1 |
| Brand | Pedrollo (Comid is listed as brand on Amazon, but manufacturer is Pedrollo) |
| Simba | 0.85 HP |
| Voltage | 220-240 Volts |
| Simba Source | Corded Electric |
| Max Flow Rate | Up to 400 l/min (24.0 m³/h) |
| Max Head | Kusvika ku11 m |
| Max Solid Particle Size | Up to 40 mm diameter |
| Item Weight | 13 makirogiramu |
8. Warranty uye Tsigiro
For warranty information, technical support, or spare parts availability, please refer to the official Pedrollo websaiti kana kubata mutengesi wako ane mvumo. Chengetedza risiti yako yekutenga sehumbowo hwekutenga kwezvichemo zvewaranti.
Availability of spare parts information is not provided in the product details. Please consult the manufacturer directly for specific inquiries.