Pedrollo Zxm1A/40

Pedrollo Vortex Zxm1A/40 Electric Submersible Pump Instruction Manual

Model: Zxm1A/40 | Manufacturer Reference: PSG 48SDZE4AA1

1. Chigadzirwa Pamusoroview

The Pedrollo Vortex Zxm1A/40 is a submersible electric pump designed for domestic drainage of wastewater, including water containing suspended solids up to 40 mm in diameter. This pump is engineered for straightforward installation and reliable automatic operation in fixed installations. It is suitable for applications requiring efficient removal of dirty water.

Pedrollo Vortex Zxm1A/40 Electric Submersible Pump

Mufananidzo 1: Pedrollo Vortex Zxm1A/40 Electric Submersible Pump. This image shows the complete pump unit, featuring a silver-colored motor housing, an orange handle, a float switch, and a blue pump body with an outlet port.

2. Safety Information

Read all safety warnings and instructions carefully before installing, operating, or performing maintenance on this product. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.

3. Setup uye Kuiswa

3.1 Kusunungura

Carefully remove the pump from its packaging. Inspect the pump for any signs of damage that may have occurred during transit. Retain packaging materials for future storage or transport.

3.2 Kuiswa

  1. Place the pump on a stable, flat surface in the lowest part of the area to be drained.
  2. Ensure the pump is fully submerged in water during operation. The float switch requires sufficient space to move freely for automatic operation.
  3. Avoid placing the pump directly on soft mud or sand, which could clog the intake. A solid base or platform is recommended.

3.3 Hose Connection

  1. Connect a suitable discharge hose to the pump's outlet port. Ensure the connection is secure and watertight to prevent leaks.
  2. Route the discharge hose away from the area to be drained, ensuring it leads to an appropriate disposal point. Avoid kinks or sharp bends in the hose that could restrict flow.

3.4 Electrical Connection

  1. Tarisa kuti magetsi emagetsi voltage matches the pump's requirements (220-240V).
  2. Connect the pump to a properly grounded electrical outlet protected by a Ground Fault Circuit Interrupter (GFCI).
  3. Ensure the power cable is not stretched, pinched, or damaged. Keep the cable away from sharp objects and hot surfaces.

4. Operating Instructions

4.1 Kutanga Kutanga

  1. After installation, ensure the pump is fully submerged and the float switch can move freely.
  2. Plug the pump into the GFCI-protected electrical outlet.
  3. The pump will start automatically when the water level rises and activates the float switch. It will stop when the water level drops and deactivates the float switch.

4.2 Kujairika Kushanda

4.3 Kuvhara

To manually stop the pump, simply unplug it from the electrical outlet. For temporary cessation of automatic operation, secure the float switch in a position that prevents it from activating.

5. Kuchengeta

Regular maintenance ensures optimal performance and extends the lifespan of your pump. Always disconnect power before performing any maintenance.

5.1 Kuchenesa

5.2 Kuchengeta

If the pump will not be used for an extended period, especially in freezing conditions:

6. Kugadzirisa matambudziko

Usati wabata rutsigiro, review zvinotevera zvinowanzoitika uye mhinduro:

DambudzikoZvinogona KukonzeraSolution
Pombi haina kutanga.No power; Float switch not activated; Clogged impeller.Check power connection and GFCI; Ensure water level is high enough to activate float switch; Disconnect power and clear impeller.
Pombi inomhanya asi hapana mvura inobuda kana kuti mvura inoyerera yakaderera.Discharge hose kinked or blocked; Pump intake clogged; Air lock; Low water level.Check and clear discharge hose; Disconnect power and clear pump intake; Briefly lift and lower pump to release air; Ensure pump is fully submerged.
Pump cycles on and off too frequently.Float switch restricted; Water level fluctuating rapidly.Check float switch for free movement; Ensure pump is placed in an area with stable water levels.

7. Zvinotsanangurwa

FeatureDetail
ModelZxm1A/40
Manufacturer ReferencePSG 48SDZE4AA1
BrandPedrollo (Comid is listed as brand on Amazon, but manufacturer is Pedrollo)
Simba0.85 HP
Voltage220-240 Volts
Simba SourceCorded Electric
Max Flow RateUp to 400 l/min (24.0 m³/h)
Max HeadKusvika ku11 m
Max Solid Particle SizeUp to 40 mm diameter
Item Weight13 makirogiramu

8. Warranty uye Tsigiro

For warranty information, technical support, or spare parts availability, please refer to the official Pedrollo websaiti kana kubata mutengesi wako ane mvumo. Chengetedza risiti yako yekutenga sehumbowo hwekutenga kwezvichemo zvewaranti.

Availability of spare parts information is not provided in the product details. Please consult the manufacturer directly for specific inquiries.

Related Documents - Zxm1A/40

Preview Mapombi Anodzika Pasi pemvura ePedrollo VX Vortex - Magadzirirwo Ehunyanzvi uye Makori eKushanda
Tsanangudzo dzakadzama dzehunyanzvi, magadzirirwo ekushanda, saizi, uye gwara rekuisa mapombi anonyudzwa mumvura ePedrollo VX Vortex. Inofukidza modhi VX40/50, VX55/50, VX40/65, VX55/65, VX75/65, VX40/80, VX55/80, uye VX75/80.
Preview Pedrollo TRITUS Submersible Mapombi ane Grinder: Mamiriro Ehunyanzvi uye Mashandisirwo
Ongorora maitiro ehunyanzvi, macurves ekuita, hukuru, uye nhungamiro yekuisa yePedrollo TRITUS submersible pombi ane magiya. Ideal for the house and civil wastewater management.
Preview Pedrollo VXC Submersible Pumps: Performance, Specifications, and Components
Detailed information on Pedrollo VXC series submersible pumps, including performance data, application limits, technical specifications, dimensions, materials, and components. Suitable for sewage, domestic use, and civil applications.
Preview VORTEX VXC4 Series Submersible Pumps - Technical Data and Specifications
Detailed technical specifications, performance curves, dimensions, and construction features for the VORTEX VXC4 series of 4-pole submersible pumps from PEDROLLO. Suitable for dirty water, civil, and industrial use.
Preview Pedrollo RX-VORTEX Submersible Pumps for Drainage - Technical Data and Performance
Detailed technical specifications, performance curves, dimensions, and materials for Pedrollo RX-VORTEX submersible pumps designed for drainage applications. Includes information on flow rates, head, power, absorption, and component details.
Preview BC TWO-CHANNEL Submersible Pumps: Technical Data, Performance, and Applications
Yakakwana tekinoroji yekumisikidzwa, macurves ekuita, ruzivo rwekuisa, uye ruzivo rwezvinhu zveBC TWO-CHANNEL nhevedzano yemapombi anodzika pasi naPedrollo. Yakanakira sewage, civil, uye maindasitiri kushandiswa.