The Fieldpiece SC620 is a professional-grade loaded clamp multimeter designed for HVACR technicians. It provides comprehensive electrical measurements including AC/DC voltage, AC current, DC microamps, frequency, temperature, and capacitance. This manual provides essential information for safe and effective operation of your SC620 multimeter. Please read this manual thoroughly before using the device.

Package Zviri mukati
The Fieldpiece SC620 package typically includes:
- SC620 Clamp Multimeter
- Test Leads with Alligator Clips
- 9V bhatiri (rakabatanidzwa)
- Mushandisi Chinyorwa (gwaro iri)
Product Features
The Fieldpiece SC620 offers a range of features for HVACR diagnostics:
- Zviyero Volts AC/DC
- Zviyero 400 Amps AC
- Zviyero Microamps DC for flame diode tests
- Zviyero Frequency via leads and clamp
- Vasina-kubata voltage (NCV) chiratidzo
- Swivel musoro for easy access in tight spaces
- Yakakwira-voltage LED and beeper kuitira kuchengeteka
- Continuity warning
- Lead holder with detachable leads and alligator probe tips
- Tembiricha uye Capacitance zviyero
Gadzirira
1. Kuiswa kwebhatiri
The SC620 multimeter requires one 9V battery for operation. The battery is typically included with the device. To install or replace the battery:
- Tsvaga bhatiri remukati chivharo kuseri kweiyo multimeter.
- Shandisa screwdriver kuvhura compartment.
- Isa bhatiri idzva re9V, uchicherechedza polarity chaiyo (+/-).
- Chengetedza chivharo chebheteri.
2. Kubatanidza Test Leads
Connect the red test lead to the VΩmA input jack and the black test lead to the COM input jack. Ensure the connections are firm. For current measurements using the clamp, no lead connection is required for the primary measurement, but leads may be used for other functions simultaneously.
Operating Instruction
1. Simba On / Off
Rotate the function dial to any measurement setting to power on the multimeter. To power off, rotate the dial to the 'OFF' position.
2. AC/DC Voltage Kuyera
Kuyera voltage:
- Rotate the function dial to the 'V~' (AC Voltage) kana 'V=' (DC Voltage) chinzvimbo.
- Batanidza tambo dzekuedza kudunhu panguva imwe chete.
- Verenga bhukutage kukosha pachiratidziro.
3. AC Current Measurement (Clamp)
Kuyera AC ikozvino:
- Rotate the function dial to the 'A~' (AC Amps) chinzvimbo.
- Vhura clamp jaw and enclose a single conductor of the circuit.
- Iva nechokwadi chekuti shaya yakavharwa zvizere.
- Verenga kukosha kwazvino kuri pachiratidziro.
4. DC Microamps Kuyera
To measure DC microamps (e.g., for flame diode tests):
- Rotate the function dial to the 'µA=' (DC Microamps) chinzvimbo.
- Connect the test leads in series with the component to be measured.
- Read the microampere value on the display.
5. Resistance and Continuity
Kuyera kuramba kana kutarisa kuenderera mberi:
- Rotate the function dial to the 'Ω' (Resistance) position.
- Batanidza bvunzo dzinotungamira mukati mechikamu.
- For continuity, the meter will beep if a low resistance path is detected.
6. Frequency Measurement
The SC620 can measure frequency via leads or clamp. Rotate the function dial to the 'Hz' position and follow the appropriate connection method.
7. Vasina-Kubata Voltage (NCV)
Press the NCV button to activate the non-contact voltage detection feature. Hold the tip of the meter near a live AC voltagchitubu. Chiyero ichi chinoratidza kuvapo kwevhoriyamutage with an LED and an audible beep.
8. Kuyera Kwekupisa
Connect a Type K thermocouple (if included, typically sold separately or as part of a kit) to the designated temperature input jacks. Rotate the function dial to the 'TEMP' position to measure temperature.
9. Capacitance Measurement
Kuyera capacitance:
- Rotate the function dial to the 'nF' (Capacitance) position.
- Ensure the capacitor is discharged before connecting the test leads.
- Batanidza matambo ekuyedza nepakati pe capacitor.
- Verenga iyo capacitance kukosha pane inoratidzwa.
Maintenance
1. Kuchenesa
Pukuta multimeter nekushambadziraamp cloth. Do not use abrasive cleaners or solvents. Ensure the device is dry before storage or use.
2. Kutsiviwa kwebhatiri
Replace the 9V battery when the low battery indicator appears on the display. Refer to the 'Battery Installation' section for instructions.
3. Kuchengeta
Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the battery to prevent leakage.
Kugadzirisa matambudziko
1. No Display or Faint Display
- Check battery charge. Replace the 9V battery if low.
- Ensure the function dial is not in the 'OFF' position.
2. Incorrect Readings
- Verify test lead connections are secure and correct for the measurement type.
- Ensure the correct function and range are selected.
- Tarisa kana paine ma "test leads" akakuvara.
- For current measurements, ensure only one conductor is clamped.
3. No Continuity Beep
- Ensure the meter is in the continuity mode.
- Check for an open circuit or high resistance in the component being tested.
Zvinotsanangurwa

| Tsanangudzo | Value |
|---|---|
| Model Number | SC620 |
| Dimensions | 3.8 x 3.2 x 14.6 inches |
| Kurema | 1.7 Pondo |
| Simba Source | 1 x 9V Bhatiri (inosanganisirwa) |
| Chiyero Type | Digital |
| Color | Black, Gray, Yellow |
| Mugadziri | Chidimbu |
| ASIN | B00KLYJS76 |
Warranty uye Support
Warranty Information
For detailed warranty information, please refer to the documentation provided with your purchase or visit the official Fieldpiece website. Chengetedza humbowo hwako hwekutenga kune warranty claim.
Mutengi Support
If you encounter any issues or have questions regarding your Fieldpiece SC620 multimeter, please contact Fieldpiece customer support through their official websaiti kana ruzivo rwekusangana rwunopihwa mune yako chigadzirwa kurongedza.