This user manual provides comprehensive instructions for the installation, operation, and maintenance of your FAAC HANDY Kit 105998 24V Automatic Gate Opener. Please read this manual carefully before beginning installation or operation to ensure safe and correct use of the product. Keep this manual for future reference.

Product Overview uye Zvikamu

The FAAC HANDY Kit 105998 is an electromechanical automation system designed for swing gates with individual leaf widths up to 2.3 meters, suitable for residential use. The kit includes advanced safety features and user-friendly components.

FAAC HANDY Kit 105998 24V Automatic Gate Opener components

An image showing the FAAC HANDY Kit 105998 components, including the main control unit, two S418 24V actuators, a FAACLIGHT 24V flashing light, an XT2 433 SLH two-channel transmitter, XP 15 B photocells, a T10 E key switch, and mounting brackets, all neatly arranged outside its packaging.

The kit typically includes the following main components:

  • 2x S418 Actuators (24V): Electromechanical arms for gate movement.
  • 1x E024S Control Unit with Enclosure: The central electronic brain of the system.
  • 1x XF433 Frequency Module: For radio signal reception.
  • 1x FAACLIGHT Flashing Light (24V): Indicates gate movement.
  • 1x XT2 433 SLH Two-Channel Transmitter: Remote control for gate operation.
  • 1x Pair of XP 15 B Photocell Sensors: Safety devices to detect obstacles.
  • 1x T10 E Key Switch: Manual override or access control.
  • 1x "Automatic FAAC" Sign: Warning sign for automated gate.
  • Mabhureki ekumisikidza uye Hardware: For installation of actuators and other components.

Safety Information

Zvakakosha: Incorrect installation or use can lead to serious injury or property damage. Always follow local safety regulations and standards. This system operates on 24V, but installation involves electrical connections. If you are not qualified, consult a professional electrician or installer.

  • Iva nechokwadi chekuti magetsi ese abviswa usati waisa kana kugadzirisa chero chinhu.
  • Chengetedza vana uye mhuka dzinovaraidza kure nenzvimbo yegedhi panguva yekushanda.
  • Do not attempt to repair or modify components unless specifically instructed in this manual.
  • The anti-crushing device and photocells are critical safety features; ensure they are correctly installed and functioning.

Setup uye Installation

Installation of the FAAC HANDY Kit requires mechanical and electrical expertise. Refer to the detailed wiring diagrams and mounting templates provided in the separate installation guide (not included in this manual but essential for setup).

  1. Mounting Actuators:

    Position the S418 actuators on the gate posts and gate leaves using the multi-position adjustable brackets. The long stroke (350mm) allows for flexible installation. Ensure correct alignment for smooth gate movement.

  2. Control Unit Installation:

    Mount the E024S control unit in a protected, accessible location near the gate. Connect all power, motor, and accessory wiring according to the provided electrical schematics.

  3. Safety Device Connection:

    Install and connect the XP 15 B photocells and FAACLIGHT flashing light. Test their functionality to ensure they detect obstacles and signal gate operation correctly.

  4. Transmitter Programming:

    Program the XT2 433 SLH transmitter with the XF433 frequency module. The Self-Learning Hopping Code (SLH) technology allows for easy duplication from transmitter to transmitter (FAAC patent).

  5. Kutanga Configuration:

    Configure the control unit settings, including gate travel limits, anti-crushing sensitivity, and automatic closing times, as per the specific requirements of your gate and local regulations.

Operating Instruction

Once installed and configured, the FAAC HANDY Kit is designed for straightforward operation.

  • Remote Control (Transmitter): Press the designated button on your XT2 433 SLH transmitter to open or close the gate. A second press during movement will stop the gate.
  • Key Switch: Insert and turn the key in the T10 E key switch to operate the gate manually or to override automatic functions.
  • Safety Features: The electronic encoder and anti-crushing device will reverse the gate's direction if an obstacle is detected during closing. The photocells will prevent the gate from closing if an object is in its path.
  • Chiedza Chinopenya: The FAACLIGHT will flash whenever the gate is in motion, providing a visual warning.

Maintenance

Kugadziriswa nguva dzose kunovimbisa kugara kwenguva refu uye kushanda kwakavimbika kwesystem yako yekuvhura gedhi.

  • Mwedzi wega wega:
    • Inspect the gate's mechanical components (hinges, wheels) for wear and tear.
    • Clean the photocell lenses to ensure unobstructed operation.
    • Test the safety features (photocells, anti-crushing) by placing an object in the gate's path during closing.
  • Pagore:
    • Check all electrical connections for corrosion or looseness.
    • Lubricate moving parts of the gate and actuators as recommended by the manufacturer.
    • Verify the integrity of mounting brackets and hardware.

For any complex maintenance or repairs, it is recommended to contact a qualified technician.

Kugadzirisa matambudziko

This section addresses common issues you might encounter with your FAAC HANDY Kit.

DambudzikoZvinogona KukonzeraSolution
Gate haripindure kure.
  • Dead transmitter battery.
  • Chinotumira chiri kure nekwachinosvika.
  • Frequency module issue.
  • Tsiva transmitter bhatiri.
  • Move closer to the gate.
  • Re-program transmitter or check XF433 module connection.
Gedhi rinomira kana kudzokera shure risingatarisirwi.
  • Obstacle detected by photocells.
  • Anti-crushing system triggered.
  • Photocells are dirty or misaligned.
  • Bvisa chero zvipingamupinyi.
  • Check gate path for resistance.
  • Clean and realign photocells.
Gedhi rinoshanda zvishoma nezvishoma kana kuti zvakaoma.
  • Mechanical friction in gate hinges.
  • Yakaderera voltage zvitengeswa.
  • Actuator wear.
  • Lubricate gate hinges and moving parts.
  • Check power supply to the control unit.
  • Contact a technician for inspection.

Kana dambudziko rikaramba riripo mushure mekuedza mhinduro idzi, ndapota taura nerutsigiro rwehunyanzvi rwakakwana.

Zvinotsanangurwa

Product ModelFAAC HANDY Kit 105998
Manufacturer Reference230813862800
BrandFAAC (Kit components), Dieffematic (Manufacturer)
Voltage24 V
Max. Gate Leaf Width2.3 meters per leaf
Actuator Stroke350 mm
Safety FeaturesAnti-crushing device, Electronic encoder with obstacle reversal, Photocell sensors
Transmitter TechnologySelf-Learning Hopping Code (SLH)

Warranty uye Support

Information regarding product warranty and specific support contacts is not available in the provided product data. Please refer to your purchase documentation or contact the retailer/manufacturer directly for details on warranty coverage and technical assistance.

Official Product Videos

No official product videos from the seller were found in the provided data. For visual guides or demonstrations, please check the manufacturer's official websaiti kana nzira dzakatenderwa.

Related Documents - 105998

Preview FAAC S418 Electromechanical Swing Gate Operator Installation uye Operation Manual
Yakakwana dhairekitori yeFAAC S418 Electromechanical Swing Gate Operator, inovhara kuisirwa, kushanda, kugadzirisa, kuchengetedza, uye hunyanzvi hwekuita. Inosanganisira ruzivo pane E024U control board uye accessories.
Preview FAAC XT2-XT4 868 SLH/SLH LR Transmitter Programming and Operation Guide
Comprehensive guide to programming and operating FAAC XT2 and XT4 868 SLH/SLH LR gate remote transmitters, including master/slave recognition and coding procedures.
Preview FAAC XT2-XT4 868 SLH - SLH LR Remote Control Programming Guide
This document provides instructions for programming and using the FAAC XT2-XT4 868 SLH - SLH LR remote control system, including identifying master/slave transmitters, system coding, and transmitter coding.
Preview FAAC S418 Swing Gate Operator - Installation and Operation Manual
Comprehensive guide for the FAAC S418 electromechanical swing gate operator, covering installation, technical specifications, safety precautions, operation, maintenance, and control board details.
Preview FAAC XTO2-XTO4 Remote Control User Manual
Comprehensive user manual for FAAC XTO2 and XTO4 remote controls, covering product information, identification, procedures for SLH, RC, SL, and DS coding, and maintenance like battery replacement and factory reset.
Preview FAAC 770 In-Ground Swing Gate Operator: Installation, Control Board, and Maintenance Manual
This manual provides comprehensive instructions for the FAAC 770 in-ground swing gate operator, covering installation, safety guidelines, the E024U control board, programming, maintenance, spare parts, and warranty. It details technical specifications and operational logic for automated vehicular swing gates.