This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your COTEC SP-700-148 Pure Sine Wave Inverter. Please read this manual thoroughly before installation and use, and retain it for future reference.
The COTEC SP-700-148 is a 700W pure sine wave inverter designed to convert 48VDC battery power to 120VAC household power, featuring dual GFCI outlets for enhanced safety.
Safety Information
WARNING: Improper installation or use can result in electric shock, fire, or damage to the inverter and connected equipment. Always follow safety guidelines.
- Ita shuwa kufefetera kwakaringana kwakatenderedza inverter.
- Usafumure iyo inverter kumvura, mvura, kana hunyoro hwakanyanya.
- Connect the inverter only to a 48VDC power source.
- Always disconnect the battery before performing any wiring or maintenance.
- Usavhura inverter casing; hapana zvikamu zvinogona kushandiswa mukati.
- This product contains materials that may be subject to California Proposition 65 warnings.
Product Overview
The COTEC SP-700-148 inverter provides reliable AC power from a DC source. Key features include:
- Kuburitsa kwakachena kwesine wave kune zvigadzirwa zvemagetsi zvinonzwa.
- Dual GFCI 120VAC outlets.
- Remote control capability (Green Terminal).
- Input & output isolation for safety.
- Temperature and load-controlled cooling fan.
- Mushandisi-ushamwari interface.
- Type 1 Indoor Aluminum Enclosure.

Setup uye Installation
1. Kuisa Inverter
Mount the inverter in a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure sufficient clearance around the unit for proper airflow, especially around the cooling fan vents.

2. Kubatanidza Kupinda kweDC
- Iva nechokwadi chekuti switch yemagetsi ye inverter iri panzvimbo ye OFF.
- Connect the positive (+) cable from your 48VDC battery bank to the positive (+) DC input terminal on the inverter.
- Connect the negative (-) cable from your 48VDC battery bank to the negative (-) DC input terminal on the inverter.
- Iva nechokwadi chekuti zvese zvinobatanidzwa zvakasimba uye zvakachengeteka kudzivirira kubatanidzwa kusina kusimba uye kukwirira.
3. Kubatanidza Kubuda kweAC
The inverter features dual GFCI 120VAC outlets. Plug your AC appliances directly into these outlets. Ensure the total power consumption of your appliances does not exceed the inverter's 700W continuous output rating.

4. Remote Control (Sarudzo)
The inverter supports a remote ON/OFF control via the green terminal block. Refer to the detailed specifications for wiring instructions if using this feature.
Operating Instruction
- After all connections are secure, switch the inverter's main power switch to the ON position.
- The inverter will perform a self-test, and the indicator lights will show its status.
- Plug your AC appliances into the GFCI outlets.
- To turn off the inverter, first disconnect all AC loads, then switch the inverter's main power switch to the OFF position.
Power Saving Mode
The inverter features an adjustable power-saving mode. Consult the full technical specifications or contact support for details on configuring this feature via the DIP switches or variable resistor.
Maintenance
- Kuchenesa: Nguva nenguva chenesai kunze kweinverter nejira rakaoma. Iva nechokwadi chekuti maburi emhepo haana guruva kana marara.
- Connections: Gara uchitarisa zvese zvinobatanidzwa neDC neAC kuti zvionekwe kuti zvakamanikana here. Zvinobatanidzwa zvisina kusimba zvinogona kukonzera kupisa zvakanyanya uye kukuvara.
- Kugadzirisa Battery: Ensure your battery bank is properly maintained according to the battery manufacturer's instructions.
- Zviri mukati: Do not attempt to service internal components. Refer all servicing to qualified personnel.
Kugadzirisa matambudziko
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| No AC output, indicator lights off. | Inverter not powered on, low battery voltage, faulty DC connection. | Check power switch, verify battery voltage, inspect DC cables and connections. |
| Inverter shuts down, fault indicator on. | Overload, over-temperature, input over/under voltage. | Reduce AC load, ensure proper ventilation, check battery voltage. Allow inverter to cool down. |
| GFCI outlet trips. | Ground fault detected in connected appliance or wiring. | Disconnect appliance, reset GFCI. If it trips again, the appliance or its wiring may be faulty. |
For issues not listed here, or if troubleshooting steps do not resolve the problem, please contact COTEC customer support.
Zvinotsanangurwa
Detailed technical specifications for the COTEC SP-700-148 Pure Sine Wave Inverter are provided below. For a comprehensive list, refer to the product's technical data sheet.
- Muenzaniso: SP-700-148
- Simba Rinoenderera: 700W
- Chiyamuro Voltage: 48VDC (Nominal)
- Kubuditsa Voltage: 120VAC
- Kuburitsa Waveform: Yakachena Sine Wave
- Frequency: 60Hz
- Dimensions: Zvinenge 14.84 x 9.84 x 5.87 inches
- Kurema Anenge 6 pounds


Warranty uye Support
COTEC products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official COTEC websaiti kana kubata mutengesi wako ane mvumo.
Please have your product model number (SP-700-148) and purchase date available when contacting support.