1. Nhanganyaya
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Red Lion RL-SWJ100 1 HP Cast Iron Shallow Well Jet Pump. Please read these instructions thoroughly before attempting to install or operate the pump. Retain this manual for future reference.

2. Safety Information
WARNING: Risk of severe injury or death by electrical shock, or damage to the system.
- Gara uchidzima simba remagetsi usati wabata pombi.
- A Ground Fault Circuit Interrupter (GFCI) is required for electrical connections.
- Kana tambo yemagetsi yakakuvadzwa, inofanira kungotsiviwa nevashandi vanokwanisa.
- Installation and servicing of this equipment should be performed by technically qualified personnel familiar with the correct selection and use of appropriate tools, equipment, and procedures.
- Chigadzirwa ichi chinogona kukuisa panjodzi yemakemikari anosanganisira lead, ayo anozivikanwa neHurumende yeCalifornia kuti anokonzera kenza uye matambudziko ekuzvarwa kana mamwe matambudziko ekubereka. Kuti uwane rumwe ruzivo enda ku www.P65Yambiro.ca.gov.

3. Chigadzirwa Pamusoroview
The Red Lion RL-SWJ100 is a 1 HP cast iron shallow well jet pump designed for providing fresh water to rural homes, farms, and cottages. It is suitable for suction lifts down to 25 feet. The pump includes a 30/50 pressure switch and is self-priming after initial prime.
Zvinokosha:
- Kushandiswa kweTsime Risina Kudzika: Designed for wells less than 25 feet deep.
- Dual Voltage Motor: Heavy-duty 115/230 Volt motor, factory-set for 230 Volts, easily switchable to 115 Volts.
- Durable Construction: Heavy-duty cast iron casing for longevity. Impeller and volute are made of glass-filled thermoplastic.
- Integrated Pressure Switch: Includes a 30/50 pressure switch with auto shut-off.
- Connections: 1-1/4-inch Female NPT threaded intake; 1-inch Female NPT threaded discharge.

4. Zvinotsanangurwa
| Attribute | Value |
|---|---|
| Model Number | 97081001 |
| Simba reBhiza (HP) | 1 HP |
| Voltage | 115/230 Volts (Dual Voltage) |
| Ampage | 13.2 Amps @ 115V; 6.6 Amps @ 230V |
| Wattage | 4800 watts |
| Maximum Flow Rate | 17 marita paminiti (GPM) |
| Maximum Pressure | 74 PSI |
| Suction/Intake | 1-1/4-inch Female NPT |
| Discharge | 1-inch Female NPT |
| Material | Cast Iron (body), Glass-filled thermoplastic (impeller/volute) |
| Zviyero zveChigadzirwa (L x W x H) | 14"L x 9"W x 9.5"H |
| Item Weight | 28.5 Pondo |
| Inosanganisirwa Zvikamu | 30/50 Pressure Switch, Instruction Manual, Pump |


5. Setup uye Kuiswa
5.1 voltage Selection
The RL-SWJ100 pump is dual voltage (115/230 Volts) and comes factory-set for 230 Volts. Ensure the pump's voltage setting matches your power source. To change the voltage, remove the cover from the motor terminal box and slide the voltage indicator switch to the desired setting (115V or 230V) using a flat screwdriver.

Video 1: This video demonstrates how to change the voltage setting on a Red Lion RL-SWJ Series Jet Pump from 230V to 115V or vice versa.
5.2 Pressure Tank Installation
If installing with a pressure tank, ensure the tank's pre-charge pressure is set correctly before installation. The pre-charge pressure should be 2 PSI below the pump's cut-in pressure setting (e.g., 28 PSI for a 30 PSI cut-in). Make all pipe connections according to local plumbing codes. Ensure the pipe size from the tank to the house is the same as the pipe size from the pump to the tank.
Video 2: This video provides instructions on how to install or adjust a pressure tank in conjunction with a jet pump system.
6. Operating Instructions
6.1 Kugadzira Pombi
Before starting the pump for the first time or after it has been drained, it must be properly primed. This involves filling the pump casing and suction line with water to ensure it can create the necessary suction to draw water from the well. Refer to the detailed priming instructions in the full owner's manual for your specific setup.
6.2 Kutanga Kutanga
After priming and ensuring all connections are secure and leak-free, restore power to the pump. The pump should start and build pressure. Monitor the pressure gauge to ensure it reaches the desired cut-off pressure (e.g., 50 PSI for a 30/50 switch). The pump will automatically shut off once the cut-off pressure is reached.
7. Kuchengeta
- Kugara Kuongorora: Nguva nenguva tarisa zvese zvakabatana kuti hazvibudi mvura uye iva nechokwadi chekuti pombi yakachengetedzwa zvakanaka.
- Kuongorora Tangi Rekumanikidza: Verify the pressure tank's air charge annually.
- Winterization: In freezing climates, drain the pump and piping completely to prevent damage from ice expansion.
- Utsanana: Keep the pump area clean and free from debris to ensure proper ventilation.
8. Kugadzirisa matambudziko
This section provides general guidance for common issues. For detailed troubleshooting steps, consult the complete owner's manual.
Matambudziko Anowanikwa:
- Pump runs but no water: Check for proper priming, ensure the suction line is submerged, and inspect for air leaks in the suction line.
- Pombi inotenderera kakawanda: This often indicates a problem with the pressure tank (low air charge, waterlogged) or a leak in the system.
- Pombi haina kutanga: Verify electrical connections, check the circuit breaker, and ensure the voltage switch is set correctly.
- Low pressure: Check for clogs in the piping, inspect the impeller for damage, and verify the well's water level.
9. Warranty uye Tsigiro
9.1 Ruzivo rweWaranti
The Red Lion RL-SWJ100 pump comes with a 2-year manufacturer's warranty. For specific terms and conditions, please refer to the warranty details provided with your product or contact Red Lion customer support.
9.2 Mutengi Tsigiro
For troubleshooting assistance, installation guidance, or to inquire about parts and service, please contact Red Lion customer support. If your product was purchased within 30 days, refer to Amazon's return policy. For purchases beyond 30 days, consult your owner's manual or contact the seller directly if different from Amazon.com.
For additional information, visit the official Red Lion websaiti: www.redlionproducts.com





