1. Nhanganyaya
This manual provides essential instructions for the installation, operation, maintenance, and troubleshooting of your APC Smart-UPS SRT 10KVA Rack Mount Uninterruptible Power Supply (UPS) with an integrated 208/240V to 120V Step-Down Transformer. Please read this manual thoroughly before installing or operating the equipment.
The APC Smart-UPS SRT 10KVA is designed to provide reliable power protection for critical electronic equipment, ensuring continuous operation during power outages and fluctuations. The integrated step-down transformer allows for flexible deployment in environments requiring 120V output from a 208/240V input source.
2. Safety Information
Yakakosha Mirayiridzo Yekuchengetedza:
- Verenga mirairo iyi nemazvo uye tarisa midziyo kuti ujairane nemudziyo usati waedza kuisa, kuishandisa, kuita sevhisi, kana kuichengeta.
- This UPS contains internal batteries and may present a shock hazard even when disconnected from the AC mains.
- Kugadziriswa kwemabhatiri kunofanirwa kuitwa kana kutarisirwa nevashandi vanoziva mabhatiri uye matanho anodiwa. Chengetedza vashandi vasina mvumo kure nemabhatiri.
- Usarase mabhatiri mumoto. Mabhatiri anogona kuputika.
- Usavhura kana kudimbura mabhatiri. Yakasunungurwa electrolyte inokuvadza ganda uye maziso. Inogona kunge ine chepfu.
- Replace batteries only with the same type and number of batteries or battery packs recommended by the manufacturer.
- Do not connect the UPS to a non-grounded outlet.
- Ensure proper grounding for all connected equipment.
- Always disconnect the UPS from the power source before performing any maintenance or service.
3. Setup
3.1 Kuburitsa uye Kuongorora
Carefully unpack the UPS and its components. Inspect for any shipping damage. If damage is found, notify the carrier and dealer. The package should contain the UPS unit, rack-mounting hardware, and documentation.
3.2 Kukwidza Rack
The SRT 10KVA RM is designed for installation in a standard 19-inch equipment rack. Follow the instructions provided with the rack-mounting kit to securely install the UPS and the step-down transformer module into the rack. Ensure adequate ventilation space around the unit.

Mufananidzo 1: Mberi view of the APC Smart-UPS SRT 10KVA Rack Mount UPS system, showing the main UPS unit and associated battery packs/step-down transformer modules installed in a rack. The central unit features a display panel indicating 'Output 208.0 V' and 'Online'.
3.3 Kubatanidzwa kweMagetsi
- Input Power: Connect the UPS input power cord to a dedicated 208V or 240V AC circuit. Ensure the circuit breaker rating is appropriate for the UPS capacity.
- Step-Down Transformer Connection: Connect the output of the main UPS unit to the input of the step-down transformer module using the provided cables.
- Output Power (120V): Connect your critical equipment to the 120V output receptacles on the step-down transformer module. Do not overload the outlets.
- Network Management Card (Optional): If applicable, install and configure the network management card for remote monitoring and control.
3.4 Yekutanga Simba-Kukwira
After all connections are secure, press the power button on the front panel of the UPS. The UPS will perform a self-test and then enter online mode. Verify the output voltage and status on the front panel display.
4. Kushanda
4.1 Front Panel Display
The front panel LCD provides real-time information about the UPS status, input/output voltage, battery charge, load level, and various alarms. Use the navigation buttons (ESC, OK, UP, DOWN) to access different menus and settings.
4.2 Basic Operation
- Kubatidza: Dzvanya wobata bhatani rekudzima kusvika chiratidziro chapenya.
- Kudzima: Press and hold the power button until the UPS shuts down. Ensure all connected equipment is safely powered off first.
- Kuzviedza: Initiate a self-test from the front panel menu to verify battery and UPS functionality.
4.3 Battery Management
The UPS continuously monitors battery health. The display will indicate battery charge level and estimated runtime. Perform periodic battery self-tests as recommended to ensure optimal performance.
5. Kuchengeta
5.1 Kutsiviwa kwebhatiri
The UPS batteries are user-replaceable. Refer to the specific battery replacement instructions provided with your replacement battery modules. Always use genuine APC replacement battery cartridges (RBCs) to ensure compatibility and safety. Battery replacement should only be performed by qualified personnel.
5.2 Kuchenesa
Keep the UPS and its ventilation openings clean and free of dust. Use a dry cloth to wipe down the exterior. Do not use liquid cleaners or solvents.
5.3 Mafungiro Ezvakatipoteredza
Operate the UPS within the specified temperature and humidity ranges. Avoid exposing the unit to direct sunlight, excessive heat, or moisture. Ensure proper airflow around the unit to prevent overheating.
6. Kugadzirisa matambudziko
This section provides solutions to common issues. For more complex problems, contact APC technical support.
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| UPS does not turn on | No input power; Battery disconnected; UPS fault | Check input power connection and circuit breaker; Ensure battery connections are secure; Contact support if fault persists. |
| UPS beeps continuously | On battery; Overload; Low battery | Check input power; Reduce load; Allow battery to recharge. |
| Hapana simba rekubuda | UPS off; Output breaker tripped; Internal fault | Turn on UPS; Reset output breaker; Contact support. |
| Nguva yekushanda kwebhatiri ipfupi | Battery nearing end of life; Overload; Battery not fully charged | Replace battery; Reduce load; Allow battery to charge for 24 hours. |
7. Zvinotsanangurwa
| Feature | Detail |
|---|---|
| Model | SRT 10KVA RM |
| Brand | APC |
| ASIN | B018JDJCQW |
| UPC | 079643813773 |
| Package Dimensions | 30 x 17 x 17 inches |
| Item Weight | 0.01 Ounces (Note: This weight may refer to packaging or a specific component, not the full unit.) |
| Mugadziri | APC / Schneider Electric |
| Zuva Rokutanga Kuwanikwa | Ndira 23, 2017 |
8. Warranty uye Tsigiro
APC provides a limited warranty for this product. For detailed warranty information, please refer to the warranty card included with your product or visit the official APC website. Technical support is available to assist with installation, troubleshooting, and product inquiries. Please have your model number and serial number ready when contacting support.