This instruction manual provides essential information for the proper installation, operation, and maintenance of the GPI 119200-551 Replacement Motor. This motor is designed to extend the service life of GPI M-150S Series fuel transfer pumps. Please read this manual thoroughly before attempting any installation or service to ensure safe and efficient use.
2. Safety Information
YAmbiro: Kutadza kutevedzera iyi mirairo yekuchengetedza kunogona kukonzera kukuvara kwakanyanya kana kukuvara kwepfuma.
- Always disconnect power to the fuel transfer pump before installing or servicing the motor.
- Ensure the work area is well-ventilated and free from ignition sources when working with fuel systems.
- Pfeka midziyo yekudzivirira yakafanira (PPE), kusanganisira magirazi ekuchengetedza uye magurovhosi.
- Refer to the original fuel transfer pump manual for additional safety guidelines specific to the pump assembly.
- This motor is designed for use with specific GPI M-150S Series fuel transfer pumps and should not be used for other applications.
3. Chigadzirwa Pamusoroview
The GPI 119200-551 is an OEM replacement motor specifically engineered for GPI M-150S Series fuel transfer pumps. It is designed to restore the performance and extend the operational life of your pump.

Mufananidzo 1: GPI 119200-551 Replacement Motor. This image displays the cylindrical motor with a silver mounting plate, a central shaft, and red and black electrical wires extending from the side.
Zvinokosha:
- Kuita: 1900 RPM, 1/5 Horsepower, 12V DC.
- Safety Standards: UL listed to US and Canadian Standards.
- Hunhu: Genuine GPI part, tested and approved for use with GPI fuel transfer pumps.
- Kwakabva Chakagadzirwa ku usa.
Kuenderana:
This replacement motor is compatible with the following GPI M-150S Series fuel transfer pump models:
- GPI M-150S-AU
- GPI M-150S-MU
- GPI M-150S-EM
- GPI M-150S-PO
- GPI M-150S-E-PO
4. Setup uye Kuiswa
Installation of the replacement motor requires careful attention to detail. It is recommended to consult the original pump's owner's manual for specific disassembly and reassembly instructions. The following steps provide a general overview:
- Bvisa Simba: Ensure the fuel transfer pump is completely disconnected from its power source (e.g., vehicle battery, power supply).
- Drain Fuel: If necessary, drain any remaining fuel from the pump and hoses to prevent spills.
- Access Motor: Carefully disassemble the pump housing to gain access to the existing motor. Note the orientation and connection points of the old motor.
- Bvisa Old Motor: Disconnect electrical wiring and mounting hardware from the old motor. Remove the old motor from the pump assembly.
- Isa Motokari Itsva: Position the new GPI 119200-551 replacement motor into the pump housing, ensuring proper alignment with the pump's internal components.
- Batanidza Wiring: Connect the electrical wires (red and black) to the corresponding terminals. Ensure secure and correct polarity.
- Secure Motor: Fasten the new motor using the appropriate mounting hardware. Ensure all connections are tight.
- Kuunganidzazve Pombi: Reassemble the pump housing, ensuring all seals and gaskets are correctly seated to prevent leaks.
- Test Operation: Reconnect power to the pump and perform a functional test with a non-flammable liquid (e.g., water) to check for proper operation and leaks before introducing fuel.
For detailed visual guides or specific model instructions, refer to the official GPI websaiti kana kubata rutsigiro rwevatengi.
5. Kushanda
Once the GPI 119200-551 replacement motor is correctly installed, the fuel transfer pump will operate according to its original specifications. Refer to your specific GPI M-150S Series fuel transfer pump's owner's manual for detailed operating procedures, including:
- Kutanga pombi.
- Connecting hoses and nozzles.
- Activating and deactivating the pump.
- Safety precautions during fuel transfer.
The replacement motor ensures the pump delivers consistent performance for efficient fuel transfer.
6. Kuchengeta
The GPI 119200-551 replacement motor is designed for durability and minimal maintenance. However, regular inspection of the overall pump system is crucial for longevity and safe operation.
- Motor Inspection: Periodically check the motor for any signs of damage, excessive heat, or unusual noise during operation.
- Mabatirwo emagetsi: Iva nechokwadi chekuti kubatanidza kwemagetsi kunoramba kwakasimba uye kusina ngura.
- Utsanana: Keep the motor and pump exterior clean and free from dirt, debris, and fuel residue.
- Pump System Maintenance: Follow the maintenance schedule outlined in your GPI M-150S Series fuel transfer pump's owner's manual for other components like hoses, nozzles, and filters.

Mufananidzo 2: GPI Spare Parts and Accessories. This image shows a GPI fuel pump nozzle attached to a pump on a green tractor, with text indicating that GPI offers a full line of spare parts and accessories for pump repair and performance enhancement.
7. Kugadzirisa matambudziko
If your fuel transfer pump experiences issues after motor replacement, consider the following common troubleshooting steps. Always disconnect power before inspecting or servicing.
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Pombi haibatike. | No power supply; loose electrical connections; faulty switch. | Check power source and fuses. Verify all electrical connections are secure. Inspect the pump's power switch. |
| Motor runs but no fuel is dispensed. | Pump not primed; clogged inlet/outlet; air leak in suction line. | Ensure pump is properly primed. Check for obstructions in hoses or nozzle. Inspect suction line for leaks. |
| Kuderera kwehuwandu hwemvura inoyerera. | Clogged filter; worn pump components (not motor related); low voltage. | Clean or replace fuel filter. Check battery voltage if 12V DC. Consult pump manual for internal component inspection. |
| Ruzha rusina kujairika kubva kumota. | Foreign object; motor bearing issue; improper installation. | Disconnect power and inspect for obstructions. If noise persists, contact GPI support. |
If troubleshooting steps do not resolve the issue, contact GPI customer support for further assistance.
8. Zvinotsanangurwa
| Attribute | Detail |
|---|---|
| Model Number | 119200-551 |
| Brand | GPI (Great Plains Industries) |
| Voltage | 12V DC |
| Horsepower | 1 / 5 HP |
| RPM | 1900 RPM |
| Material | Aluminium |
| Dimensions (L x W x H) | 12 x 6 x 7 inches |
| Item Weight | 6.43 makirogiramu |
| Fit Type | Universal Fit (for specified M-150S Series pumps) |
| YeMotokari Sevhisi Type | Truck, Tractor, Heavy Machinery |
| Kuenderana kweRudzi rweGasi | peturu |
| Certifications | UL yakanyorwa kuUS uye Canadian Standards |
| UPC | 031401002768 |
9. Ruzivo rweWaranti
GPI Genuine Parts & Accessories, including the 119200-551 Replacement Motor, are backed by a 90-day limited manufacturer's warranty. Iyi waranti inovhara kukanganisa mune zvigadzirwa uye magadzirirwo pasi pekushandiswa kwakajairwa.
For specific warranty terms and conditions, or to make a warranty claim, please refer to the documentation included with your product or visit the official Great Plains Industries website.
10. Kutsigira uye Kubata
For technical assistance, troubleshooting guidance, or inquiries regarding replacement parts, please contact Great Plains Industries customer support.
- Product Support: Available by phone on weekdays.
- Mabhuku eVaridzi: All GPI owner's manuals are available for download on the official Great Plains Industries website.
- Websaiti: www.gpipumps.com
Kana muchibata rutsigiro, ndapota ivai nenhamba yenyu yemhando yechigadzirwa (119200-551) uye chero ruzivo rwekutenga rwakakodzera.