1. Nhanganyaya
The HT Instruments IRONMETER is a professional and precise True RMS (TRMS) digital multimeter designed for robust performance. Its shock-resistant and break-proof casing ensures durability in demanding environments. This compact, portable device integrates all essential functions of a true RMS multimeter, making it suitable for a wide range of electrical applications.
The IRONMETER complies with IEC/EN 61010-1 standards and is rated for Overvoltage Category CAT III 600 V, ensuring safe and reliable operation.
2. Ruzivo Rwakakosha Chekuchengetedza
Always adhere to the following safety precautions to prevent personal injury and damage to the instrument:
- Read this manual thoroughly before using the multimeter.
- Usapfuure miganhu yepamusoro yekupinda chero basa.
- Never use the meter if it or the test leads appear damaged.
- Chenjerera paunenge uchishanda nevoltages pamusoro pe30V AC RMS, 42V peak, kana 60V DC. Aya voltages inokonzeresa njodzi.
- Gara uchibvisa ma "test leads" kubva mu "circuit" usati wachinja mashandiro kana kuti "ranges".
- Iva nechokwadi chekuti basa rakakodzera uye huwandu hwakakodzera zvasarudzwa pakuyera.
- Tsiva mabhatiri ipapo ipapo kana chiratidzo chebhatiri diki chaonekwa.
- Usashandise mita munzvimbo dzine gasi rinoputika, utsi, kana guruva.
3. Package Zviri mukati
Ona kuti zvinhu zvese zviripo uye hazvina kukuvara pakuburitsa:
- 1 x HT Instruments IRONMETER Digital Multimeter
- 2 x Test Leads with 4mm Test Probes
- 2 x AAA Mabhatiri
- 1 x Chinyorwa cheMushandisi
4. Setup
4.1 Kuiswa kwebhatiri
The IRONMETER requires 2 AAA batteries for operation. To install or replace batteries:
- Ensure the multimeter is turned OFF and disconnect any test leads.
- Tsvaga chivharo chebhatiri kuseri kwemudziyo.
- Shandisa sikurudhiraivha kusunungura sikurudhi inosunga chifukidziro.
- Remove the cover and insert the 2 AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Replace the battery compartment cover and tighten the screw(s).

Mufananidzo 1: Mberi view of the HT Instruments IRONMETER Digital Multimeter, showing the display, rotary dial, and input jacks.
4.2 Kubatanidza Miedzo Inotungamira
To prepare the multimeter for measurements:
- Insert the black test lead into the 'COM' (Common) input jack.
- Insert the red test lead into the appropriate input jack for your measurement:
- 'VΩHz%CAP' for Voltage, Resistance, Frequency, Duty Cycle, and Capacitance measurements.
- '10A' for current measurements up to 10A (or 20A max for 30 seconds).
- 'µAmA' for microampere uye milliampzviyero zvazvino.

Figure 2: The IRONMETER in an active measurement scenario, demonstrating proper test lead connection and usage.
5. Operating Instructions
The IRONMETER features a large LCD with backlight for clear readings and a rotary dial for function selection.
5.1 Power On/Off and Auto Power Off
- To turn the meter ON, rotate the function dial from 'OFF' to any desired measurement function.
- To turn the meter OFF, rotate the function dial to the 'OFF' position.
- The meter features an Auto Power Off function to conserve battery life. It will automatically power off after a period of inactivity.
5.2 Kuyera Mabasa
5.2.1 AC/DC Voltage Measurement (0.001 V to 600 V)
Set the rotary dial to the 'V~' (AC Voltage) kana 'V=' (DC Voltage) position. Connect the test leads in parallel to the circuit or component under test. The display will show the voltage kuverenga.
5.2.2 AC/DC Current Measurement (0.1 µA to 10 A, 20 A max for 30 sec)
Set the rotary dial to the 'µAmA~', 'µAmA=', '10A~', or '10A=' position. Connect the test leads in series with the circuit. Ensure the correct input jack (µAmA or 10A) is used based on the expected current. The display will show the current reading.
5.2.3 Resistance Measurement (0.1 Ω to 40 MΩ)
Set the rotary dial to the 'Ω' position. Connect the test leads across the component to measure its resistance. Ensure the component is de-energized before measuring resistance.
5.2.4 Continuity and Diode Test
Set the rotary dial to the 'Diode/Continuity' position. For continuity, connect the leads across the circuit; a low resistance will trigger an audible beep. For diode test, connect the leads across the diode; the display will show the forward voltage kudonha
5.2.5 Frequency Measurement (up to 10 kHz)
Set the rotary dial to the 'Hz' position. Connect the test leads to the signal source. The display will show the frequency in Hertz.
5.2.6 Capacitance Measurement (0.01 nF to 4000 µF)
Set the rotary dial to the 'CAP' position. Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement. The display will show the capacitance in Farads.
5.3 Mabasa Akakosha
5.3.1 Data Bata
Dzvanya bhatani re'BATA' kuti umise kuverenga kwazvino pachiratidziro. Dzvanya iyo zvakare kuti usunungure basa rekubata.
5.3.2 Max/Mini Basa
Press the 'MAX/MIN' button to activate the maximum/minimum value recording. The meter will continuously record the highest and lowest readings. Press again to cycle between MAX, MIN, and current readings.
5.3.3 Duty Cycle
When in Frequency mode, the 'MODE' button may allow switching to Duty Cycle measurement, displaying the ratio of pulse width to period.
5.3.4 Backlight uye Tochi
The IRONMETER features a large LCD with backlight for improved visibility in low-light conditions. Press the backlight button (often integrated with the 'MODE' or a dedicated light button) to activate it. An integrated white LED flashlight is also available for illuminating the work area.

Figure 3: The IRONMETER's robust design, built to withstand demanding industrial environments.
6. Kuchengeta
6.1 Kutsiviwa kwebhatiri
When the low battery indicator appears on the display, replace the batteries as described in Section 4.1. Always use fresh AAA batteries.
6.2 Kuchenesa
Kuti uchenese multimeter, pukuta bhokisi racho nekushambadziraamp jira nesipo isina kusimba. Usashandise zvinogumbura kana zvinonyungudutsa. Iva nechokwadi chekuti mita yacho yakaoma zvachose usati washandisa.
7. Kugadzirisa matambudziko
If you encounter issues with your IRONMETER, refer to the following common problems and solutions:
- Hapana Chiratidziro/Mita Isingabatidzi: Tarisa kuiswa kwebhatiri uye ona kuti mabhatiri haana kupera. Dzorera kana zvakakodzera.
- Kuverenga Kusina kururama: Verify that the correct function and range are selected. Ensure test leads are properly connected and not damaged. Check for proper circuit connection.
- 'OL' or 'OVER' Display: Indicates an overload or out-of-range measurement. Select a higher range or ensure the input is within the meter's specifications.
- Kuverenga Kwenguva: Check for loose connections at the test leads or within the circuit.
Kana dambudziko rikaramba riripo mushure mekuedza mhinduro idzi, taura nerutsigiro rwevatengi.
8. Zvinyorwa zveUnyanzvi
| Tsanangudzo | Value |
|---|---|
| Model Number | IRONMETER |
| Brand | HTI |
| Simba Source | Battery Powered (2 x AAA, included) |
| Dimensions (L x W x H) | 18 x 13 x 7 cm |
| Item Weight | 200 magiramu |
| Voltage Kuyera (TRMS) | 0.001 V to 600 V AC/DC |
| Chiyero Chazvino | 0.1 µA to 10 A AC/DC (20 A max. 30 sec) |
| Resistance Measurement | 0.1 Ω kusvika 40 MΩ |
| Capacitance Measurement | 0.01 nF to 4000 µF |
| Frequency Measurement | Kusvika ku10 kHz |
| Continuity Test | Ehe |
| Diode Bvunzo | Ehe |
| Anokosha Mabasa | Data Hold, Max/Min, Duty Cycle, Backlight, Integrated LED Flashlight, Auto Power Off |
| Safety Rating | CAT III 600 V, IEC/EN 61010-1 |
| Nyika Yekwakabva | Jerimani |
| Kutanga Kuwanikwa Zuva | Chivabvu 5, 2016 |
| Spare Parts Availability (EU) | 1 Gore |
9. Warranty uye Tsigiro
The HT Instruments IRONMETER Digital Multimeter comes with a standard warranty covering manufacturing defects. Spare parts are available for a period of 1 year from the date of purchase within the EU.
For technical support, warranty claims, or service inquiries, please contact HT Instruments customer service through their official website or the contact information provided with your purchase documentation. Please have your model number (IRONMETER) and purchase details ready when contacting support.