Smith's Environmental Products B628330

Smith's Environmental Products Quiet-One Kickspace Fan Heater

Model: B628330 (KS2008, 8000 BTU)

1. Nhanganyaya

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Smith's Environmental Products Quiet-One Kickspace Fan Heater, Model B628330. This unit is designed to provide supplemental heat by circulating hot water from your central heating system through a heat exchanger and distributing the warmth with an integrated fan. Please read all instructions carefully before installation and use.

2. Safety Information

WARNING: Failure to follow these safety instructions could result in fire, electric shock, property damage, serious injury, or death.

  • Professional Installation Inokurudzirwa: Installation of this hot water fan heater requires plumbing and electrical connections. It is strongly recommended that installation be performed by a qualified plumber and a licensed electrician in accordance with all local and national codes.
  • Kuchengetedzwa Kwemagetsi: Ensure the unit is properly grounded. Disconnect power before servicing or performing any maintenance. Do not operate with a damaged cord or plug.
  • Kuchengetedzwa Kwemvura: Ensure all water connections are secure and leak-free. Do not operate if water leakage is detected.
  • Kuiswa: Do not block air intake or exhaust vents. Maintain adequate clearance around the unit for proper airflow.
  • Vana uye Zvipfuwo: Keep children and pets away from the unit during operation, as surfaces may become hot.
  • Zvishandiso zvinopisa: Do not store or use flammable materials near the heater.
  • Zvinotarisirwa Kushandiswa: This heater is designed for indoor use only, specifically for heating residential or commercial spaces. Do not use for drying clothes or other unintended purposes.

3. Package Zviri mukati

Carefully unpack the box and ensure all items are present and undamaged. If any items are missing or damaged, contact your supplier immediately.

  • Quiet-One Kickspace Fan Heater Unit (Model B628330)
  • Bhuku reKuisa uye reMushandisi (gwaro iri)
Smith's Environmental Products Quiet-One Kickspace Fan Heater unit

Image 1: The Smith's Environmental Products Quiet-One Kickspace Fan Heater unit. This image shows the compact design of the heater, featuring a brown casing with a front grille for air output and a top grille for air intake.

4. Zvinotsanangurwa

The following table outlines the key specifications for the Quiet-One Kickspace Fan Heater, Model B628330:

FeatureTsanangudzo
BrandSmith's Environmental Products
Model NumberB628330 (KS2008)
Heat Output8000 BTU
Heat Source TypeHot Water (from central heating system)
Electrical Power (Fan)120V
Special FeatureKushanda kusina ruzha
ColorBhurawuni
Fomu FactorCabinet / Kickspace
Indoor / Outdoor KushandiswaIndoor
Zviyero zveChigadzirwa (D x W x H)10.88" x 13.88" x 3.5"
Mounting TypeFloor Mount (Kickspace)
Room TypeBedroom, Living Room, Kitchen (under cabinet)
Item Weight15 makirogiramu
ZvibvumiranoUL, CSA, RTS
Smith's Environmental Products Quiet-One Kickspace Fan Heater with dimensions

Image 2: The Smith's Environmental Products Quiet-One Kickspace Fan Heater with its key dimensions labeled. The image clearly shows the depth (10.88"), width (13.88"), and height (3.5") of the unit, essential for installation planning.

5. Kuiswa uye Setup

IMPORTANT: Installation must comply with all local and national electrical and plumbing codes. It is highly recommended that a qualified professional perform the installation.

5.1 Sarudzo yeSaiti

  • Choose a location with sufficient space for the unit (refer to dimensions in Section 4) and adequate clearance for air circulation.
  • Typically installed in a kickspace under cabinets, stairs, or other confined areas.
  • Ensure the location allows for easy access for maintenance and servicing.

5.2 Plumbing Connections

  • This unit connects to your existing hot water heating system.
  • Connect the supply and return lines from your heating system to the heater's heat exchanger connections.
  • Use appropriate fittings and sealants to ensure watertight connections.
  • Bleed air from the system after filling to ensure proper water flow.

5.3 Kubatanidzwa kweMagetsi

  • The unit requires a 120V electrical supply to power the fan.
  • Connect the heater to a dedicated, grounded electrical circuit protected by a fuse or circuit breaker of the appropriate rating.
  • Follow all wiring diagrams provided with the unit (if applicable) and adhere to local electrical codes.
  • Ita shuwa kuti zvese zvinongedzo zvakachengeteka uye zvakavharirwa.

5.4 Macheki ekupedzisira

  • Verify all plumbing connections are free of leaks.
  • Confirm all electrical connections are secure and correctly wired.
  • Ensure the unit is properly mounted and stable.
  • Check that air intake and exhaust grilles are unobstructed.

6. Kushanda

Once properly installed and connected, operating your Quiet-One Kickspace Fan Heater is straightforward.

  • Power On: Ensure the electrical supply to the unit is switched on.
  • Thermostat Control: The heater typically operates in conjunction with your central heating system's thermostat. When the room temperature drops below the thermostat setting, the central heating system will circulate hot water to the unit, and the fan will activate to distribute the heat.
  • Fan Speed (if applicable): Some models may feature a fan speed switch (e.g., Low/High). Adjust this switch to your desired airflow and noise level. Refer to any specific controls on your unit.
  • Vhara: To turn off the heater, simply turn off the central heating system or switch off the electrical supply to the unit.

7. Kuchengeta

Kugara kugadziridza kunovimbisa kuita kwakaringana uye hupenyu hurefu hweheater yako.

  • Kuchenesa: Periodically clean the air intake and exhaust grilles to prevent dust and debris buildup, which can restrict airflow and reduce efficiency. Use a soft brush or vacuum cleaner.
  • Filter (if applicable): Some models may include an air filter. Check and clean or replace the filter as recommended in specific product documentation.
  • Kuongorora Kwegore: It is advisable to have a qualified technician inspect the unit annually, especially before the heating season, to check for leaks, electrical connections, and overall operational integrity.
  • Do Not Lubricate: The fan motor is typically permanently lubricated and does not require additional oiling.

8. Kugadzirisa matambudziko

If you encounter issues with your heater, refer to the following common problems and solutions. If the problem persists, contact a qualified technician.

DambudzikoZvinogona KukonzeraSolution
Hapana kubuda kupisaNo hot water circulating; Thermostat not calling for heat; Air in heating system; Blocked heat exchanger.Check central heating system and thermostat settings; Bleed air from the heating system; Contact a plumber.
Fani haisi kushandaNo electrical power; Fan motor failure; Thermostat not calling for heat.Check circuit breaker/fuse; Ensure unit is plugged in; Verify thermostat setting; Contact an electrician or service technician.
Kuyerera kwemhepo kwakaderedzwaBlocked grilles; Dirty filter (if applicable).Clean grilles; Clean or replace filter.
Ruzha rusina kujairikaLoose components; Fan obstruction; Motor bearing wear.Inspect for loose parts; Clear any obstructions; Contact a service technician for motor issues.
Kubuda kwemvuraLoose plumbing connections; Damaged heat exchanger.Tighten connections; Immediately shut off water supply and contact a qualified plumber.

9. Warranty uye Tsigiro

For warranty information, please refer to the documentation provided at the time of purchase or visit the official Smith's Environmental Products website. If you require technical assistance, replacement parts, or service, please contact Smith's Environmental Products customer support directly. Ensure you have your model number (B628330) and purchase date available when contacting support.

Contact Information: Ndapota tarisai kune mukuru wemugadziri webwebhusaiti kana magwaro ako ekutenga kuti uwane ruzivo rwemazuva ano rwekuonana.

Related Documents - B628330

Preview Smith's Environmental Products: Heating System Accessories Glossary and Compatibility
A comprehensive guide to Smith's Environmental Products' heating system accessories, detailing their functions and compatibility across various Caspian and Ecovector product lines.
Preview Smith's Environmental Products: Latest Updates on Space Saver Heaters, Ostro ONE, Caspian 75 & Heat Pump Integration - November 2025
Read the November 2025 issue of #ThinkSmiths from Smith's Environmental Products. Features include the upgraded Space Saver Hydronic Plinth Heater with EasiLink, the new Ostro ONE air curtain, Caspian 75 fan convectors, and expert advice on heat pump integration. Details on Eco-Powerad discontinuation and holiday closures.
Preview Smith's Aegean SFC 260H Fan Coil Unit: Technical Specification and Overview
Detailed technical specifications, features, and application information for the Smith's Aegean SFC 260H fan coil unit, designed for efficient commercial heating and cooling.
Preview Caspian® SL Fan Convectors - Unyanzvi Zvinotsanangurwa & Kuodha Guide | Smith's Environmental Products
Yakadzama tekinoroji maratidziro, kupisa kuburitsa data, uye kuodha ruzivo rweSmith's Caspian® SL EC mota fan fan convector. Ideal for commercial heat solutions.
Preview Ostro One Air Curtain: Chigadzirwa Pamusoroview uye Specifications
Ziva iyo Ostro One mhepo keteni, yazvino uye yakashongedzwa mhinduro yekugadzira nharaunda dzakagadzikana muzvikoro, zvitoro, macafe, uye maresitorendi. Dzidza nezve maficha ayo, sarudzo dzechigadzirwa (Ostro IMWE C ​​uye Ostro IMWE E), hunyanzvi hwekuita, uye ruzivo rwekuodha.
Preview Aegean SFC 235H Fan Coil Unit - Technical Specifications and Overview
Detailed pamusoroview, dimensions, specifications, and technical data for the Smith's Environmental Products Aegean SFC 235H fan coil unit, suitable for commercial heating and cooling applications.