JahyShow Air Compressor Pressure Switch Control (BM-Y157) Instruction Manual

Nhanganyaya

This manual provides detailed instructions for the installation, operation, and maintenance of your JahyShow Air Compressor Pressure Switch Control, model BM-Y157. This heavy-duty 26A single-port pressure switch is designed to regulate air pressure in compatible air compressors, helping to optimize energy consumption and ensure safe operation.

Safety Information

YAMBIRO: Always disconnect power to the air compressor and ensure it is fully depressurized before installing, servicing, or adjusting the pressure switch. Failure to do so can result in serious injury or death.

Product Overview

The JahyShow BM-Y157 pressure switch is a robust component for air compressor systems. It features a single 1/4" NPT female port for connection and an integrated ON/OFF switch lever for manual control. An unloader valve is also included to release air pressure from the compressor head when the motor stops, facilitating easier restarts.

JahyShow Air Compressor Pressure Switch, front and side view.

This image displays the JahyShow Air Compressor Pressure Switch, showing its main body, pressure port, and the ON/OFF lever.

Zvinokosha:

Zvinotsanangurwa

Model NumberBM-Y157
Default On (Cut-in) Pressure90 PSI
Default Off (Cut-out) Pressure120 PSI
Adjustable Pressure RangeMin On: 35 PSI, Max Off: 150 PSI
Differential30-40 ​​PSI
Pole RatingPole
Single Phase Rating20 Amps at 120V AC / 12 Amps pa 240V AC
Three Phase Rating9.6 Amps pa 240V AC
Kunonyanyisa Voltage240V AC
Port Mhando1/4" NPT Single Female Port
Operation ModeON-OFF
Contact TypeKazhinji Yakavharwa
International Protection RatingIP54
MaterialPlastiki
Item Weight12.7 ounces

Setup uye Installation

Follow these steps for proper installation of the pressure switch:

  1. Kudzima Simba: Ensure the air compressor is unplugged from its power source and completely depressurized before beginning any work.
  2. Bvisa Old Switch (kana zvichibvira): Carefully disconnect all wiring from the existing pressure switch. Note the wiring configuration for correct re-connection. Unscrew the old pressure switch from the air compressor manifold.
  3. Prepare New Switch: Apply thread sealant, such as PTFE (Teflon) tape, to the 1/4" NPT male threads of the new JahyShow pressure switch. Wrap the tape clockwise around the threads for a secure, leak-free seal.
  4. Isa Switch Itsva: Screw the new pressure switch into the manifold port on your air compressor. Hand-tighten first, then use a wrench to tighten securely. Do not overtighten, as this can damage the threads or the switch housing.
Pasi view of JahyShow Air Compressor Pressure Switch, showing the 1/4 inch NPT port.

This image shows the underside of the pressure switch, clearly displaying the 1/4 inch NPT single female port for connecting to the air compressor manifold.

  1. Wire Connections: Connect the electrical wires to the appropriate terminals on the new switch. Refer to the original wiring configuration or your compressor's manual for correct connections. This switch is rated for 20A at 120V AC or 12A at 240V AC (single phase). Ensure all connections are tight and insulated.
  2. Tarisa uone Mavuza: Once installed and wired, repressurize the air compressor system. Apply soapy water to all connections, especially around the new switch, to check for any air leaks. Bubbles indicate a leak that needs to be addressed.

Operating Instruction

The pressure switch automatically controls the air compressor's motor based on the tank pressure. It also features a manual ON/OFF lever.

Mberi view of JahyShow Air Compressor Pressure Switch with pressure connection and ON/OFF lever.

Kutungamira zvakananga view of the pressure switch, detailing the central pressure connection point and the red-tipped ON/OFF lever for manual control.

  1. Batidza/Kudzima: Use the integrated ON/OFF switch lever to manually control the compressor. Move the lever to the 'ON' position to allow automatic operation. Move it to the 'OFF' position to stop the compressor and prevent automatic restarts.
  2. Automatic Operation: When the lever is in the 'ON' position, the compressor will automatically start when the tank pressure drops below the factory-set cut-in pressure (default 90 PSI). It will then run until the tank pressure reaches the factory-set cut-out pressure (default 120 PSI), at which point it will automatically shut off.
  3. Pressure Adjustment: The cut-in and cut-out pressures are adjustable within the specified range (Min On: 35 PSI, Max Off: 150 PSI). To adjust, locate the adjustment screw (typically under a protective cover or accessible from the top of the switch). Turn the screw clockwise to increase both cut-in and cut-out pressure settings, and counter-clockwise to decrease them. Make small adjustments and test the system's operation to achieve desired pressure levels.

Maintenance

Regular maintenance helps ensure the longevity and reliable operation of your pressure switch:

Kugadzirisa matambudziko

If you encounter issues with your pressure switch, refer to the following common problems and solutions:

Warranty Information

JahyShow products are designed for durability and performance. For specific warranty details regarding your BM-Y157 Air Compressor Pressure Switch Control, please refer to the product packaging or contact JahyShow customer support directly. Keep your purchase receipt as proof of purchase.

Support

For technical assistance, product inquiries, or to report any issues, please visit the official JahyShow store on Amazon or contact their customer service directly through the provided channels on their store page.

JahyShow Store Link: Visit the JahyShow Store

Related Documents - BM-Y157

Preview PATLITE Signal Phone BM Series Instruction Manual
Yakakwana yekuraira bhuku rePATLITE Signal Runhare BM akatevedzana, anotsanangura maidi, kukwira, wiring, kuchengetedza kushanda, uye modhi yeruzivo rwekushandiswa kwekutengesa.
Preview Interroll Conveyor Lines: Medium and Heavy Duty Solutions Catalog
Explore Interroll's comprehensive catalog of medium and heavy-duty conveyor lines, including roller conveyors, belt conveyors, and sorting/distributing systems. Find detailed specifications, model numbers, and ordering information for industrial material handling solutions.
Preview EKA Electronic Black Mask Ovheni Inoshanda uye Yekuraira Chinyorwa
Yakakwana yekushanda uye yekuraira bhuku reEKA Electronic Black Mask Oveni, kusanganisira modhi MKF 464 BM kusvika MKF 2011 BM. Gwaro iri rinobata kuisirwa, kuchengetedza, mashandiro, mabasa ekubikira, manejimendi ekubika, kuchenesa, kugadzirisa matambudziko, uye ruzivo rwewaranti yekushandiswa kwehunyanzvi mukicheni.
Preview Aigostar Bluetooth Mesh Smart Downlights Quick Start Guide
Get started with your Aigostar Bluetooth Mesh Smart Downlights. This guide covers setup, control methods including Aigostar App, Alexa, and DC dimmer switch, and troubleshooting.
Preview Beurer BM 49 Speaking Upper Arm Blood Pressure Monitor Instructions
Comprehensive instructions for the Beurer BM 49, a speaking upper arm blood pressure monitor. Learn about its features, proper usage, safety precautions, and maintenance for accurate blood pressure and pulse readings.
Preview Wartung und Pflege der Columbus RA 85 BM 90 Scheuersaugmaschine
Umfassende Anleitung zur Wartung und Instandhaltung der Columbus RA 85 BM 90 Scheuersaugmaschine. Erfahren Sie Schritt für Schritt, wie Sie Ihre Reinigungsmaschine optimal pflegen und ihre Lebensdauer verlängern.