Immergas Victrix Tera 28KW

Immergas Victrix Tera 28KW Condensing Boiler User Manual

Model: Victrix Tera 28KW (Model Number: 3027369)

1. Nhanganyaya

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Immergas Victrix Tera 28KW Condensing Boiler. Please read this manual thoroughly before attempting any installation, operation, or maintenance procedures. Retain this manual for future reference.

The Immergas Victrix Tera 28KW is a high-efficiency condensing boiler designed for domestic heating. It features a low-consumption circulator for energy savings and a user-friendly interface with practical buttons and a backlit display for easy control and monitoring.

2. Safety Information

Yakakosha Mirayiridzo Yekuchengetedza:

3. Chigadzirwa Pamusoroview

The Immergas Victrix Tera 28KW Condensing Boiler is designed for efficient heating. Its compact design and aesthetic hydraulic connection cover make it suitable for various domestic environments.

Immergas Victrix Tera 28KW Condensing Boiler, kumberi view

Mufananidzo 1: Mberi view of the Immergas Victrix Tera 28KW Condensing Boiler. The image shows a white, rectangular boiler unit with a control panel featuring a digital display and several buttons located on the lower front section. A pressure gauge is visible to the right of the control panel. The top of the unit has a dark grey vent or exhaust component.

Zvinokosha:

4. Setup uye Kuiswa

Installation of the Immergas Victrix Tera 28KW Condensing Boiler must be carried out by a certified professional in compliance with all applicable local and national codes and regulations. Incorrect installation can lead to serious injury, property damage, or void the warranty.

General Guidelines (for professional installers):

5. Operating Instructions

The Immergas Victrix Tera 28KW boiler features an intuitive control panel with a backlit display. Refer to the detailed instructions below for basic operation.

Kudzora Panel Pamusoroview:

Panel yekudzora inowanzo sanganisira:

Starting the Boiler:

  1. Onai kuti vharafu gasi vharafu rakavhurika.
  2. Verify that the system water pressure, indicated by the pressure gauge, is within the recommended range (typically 1.0 to 1.5 bar). If not, repressurize the system as per installation instructions.
  3. Switch on the electrical power supply to the boiler.
  4. Select the desired operating mode (e.g., heating and DHW) using the mode selection buttons.
  5. Set the desired heating and/or DHW temperatures using the adjustment buttons.
  6. The boiler will initiate its start-up sequence.

Shutting Down the Boiler:

  1. Switch the boiler to standby mode or turn off the main power switch.
  2. For extended periods of inactivity (e.g., summer), it is recommended to close the gas supply valve.
  3. During winter, if the boiler is shut down, ensure adequate frost protection measures are in place for the heating system.

6. Kuchengeta

Regular maintenance is crucial for the safe, efficient, and long-lasting operation of your Immergas Victrix Tera 28KW boiler. All maintenance work, especially internal components, must be performed by a qualified service technician.

User Maintenance (Monthly/Quarterly):

Professional Annual Maintenance:

It is mandatory to have your boiler serviced annually by a qualified and certified technician. This service typically includes:

7. Kugadzirisa matambudziko

This section provides solutions for common issues. For complex problems or if an error code persists, contact a qualified service technician.

DambudzikoZvinogona KukonzeraSolution
Hapana kudziyisa kana mvura inopisaNo power supply; Gas supply off; Low system pressure; Thermostat setting too low; Boiler lockout.Check power switch and circuit breaker; Ensure gas valve is open; Check pressure gauge (repressurize if needed); Adjust thermostat; Press boiler reset button. If issue persists, contact technician.
Boiler inoita ruzha rusingawanzoitikiMhepo iri musystem; Kuungana kweLimescale; Dambudziko repombi.Bleed radiators to remove air; Contact technician for limescale removal or pump inspection.
Low system pressureWater leak; Expansion vessel fault.Check for visible leaks and repair; Repressurize the system. If pressure drops frequently, contact a technician.
Boiler iri kuratidza kodhi yekukanganisaChikanganiso chaicho chakaonekwa nekuongorora kwemukati mebhaira.Note the error code and consult the full technical manual (if available) or contact a qualified technician, providing them with the error code. Try pressing the reset button once.

8. Zvinotsanangurwa

The following specifications are for the Immergas Victrix Tera 28KW Condensing Boiler (Model Number: 3027369).

9. Warranty uye Tsigiro

For specific warranty terms and conditions, please refer to the warranty card included with your product or contact Immergas customer support directly. Keep your proof of purchase for warranty claims.

For technical assistance, spare parts, or to schedule service, please contact your authorized Immergas dealer or a qualified heating technician.

Information regarding spare parts availability is currently unavailable. Please contact Immergas support for details.

Related Documents - Victrix Tera 28KW

Preview Bhuku rekushandisa reImmergas Victrix Pro V2 35/55/60/68/80 EU: Kuisa, Kushanda, uye Kugadzirisa
Bhuku rekushandisa rakakwana reImmergas Victrix Pro V2 35/55/60/68/80 EU condensing boiler. Rinovhara kuiswa, kushandiswa, kugadziriswa, nhungamiro dzekuchengetedza, uye hunyanzvi hwekuita kuti ishande zvakanaka uye igare kwenguva refu.
Preview Bhuku rekushandisa reImmergas VICTRIX OMNIA: Gwaro rekuisa, kushandisa, uye kugadzirisa
Bhuku rekushandisa rakakwana reImmergas VICTRIX OMNIA condensing boiler. Rinosanganisira mirairo yekuisa, nhungamiro dzekushandisa, maitiro ekugadzirisa, hunyanzvi, uye kugadzirisa matambudziko kuti ishande zvakanaka uye ive yakachengeteka.
Preview Immergas VICTRIX PRO V2 EU: Pepa rehunyanzvi reMaboilers ane Simba Repamusoro
Pepa rehunyanzvi rakakwana reImmergas VICTRIX PRO V2 EU series yemaboiler ane simba guru, anorembera pamadziro. Tsanangudzo dzakadzama, maficha, mamodheru (35-180 EU), sarudzo dzekuisa, zvishongedzo, uye data rehunyanzvi remhinduro dzekupisa dzinoshanda.
Preview Immergas Victrix Tera V2 28-32-38 EU User and Installation Manual
Comprehensive user and installation manual for the Immergas Victrix Tera V2 condensing boiler series (models 28, 32, and 38 EU). Find detailed instructions for installation, operation, maintenance, and technical specifications.
Preview Mabhoyira eImmergas Victrix Tera V2 Series Condensing: Bhuku reMushandisi, Kuisa, uye Kugadzirisa
Gwaro rakakwana remaboiler eImmergas Victrix Tera V2 series condensing (V28, V32, V38 EU). Rinovhara kuiswa, kushandiswa, kugadziriswa, uye ruzivo rwehunyanzvi kune vanoisa, vashandisi, uye matekiniki.
Preview Immergas Victrix TERA 24 PLUS Bhuku reMushandisi
Yakazara mushandisi bhuku reImmergas Victrix TERA 24 PLUS, rinofukidza kuisirwa, kushanda, uye kugadzirisa. Inosanganisira maitiro ehunyanzvi uye mirairo yekuchengetedza.