1. Nhanganyaya uye Pamusoroview
This manual provides essential instructions for the safe and efficient operation, setup, and maintenance of your Geko G80410 15 kW LPG Gas Heater. Please read this manual thoroughly before using the appliance and retain it for future reference. This heater is designed for heating well-ventilated areas and operates on Liquefied Petroleum Gas (LPG).

Mufananidzo 1.1: Mberi view of the Geko G80410 15 kW LPG Gas Heater, showcasing the main unit, attached gas hose, and pressure reducer. The heater features a black casing with the Geko logo and control panel visible.
2. Safety Information
WARNING: Failure to follow these safety instructions may result in fire, explosion, serious injury, or death.
- Kufefetedza Always use this heater in a well-ventilated area to prevent oxygen depletion and carbon monoxide poisoning. Do not use in enclosed spaces.
- Mafuta: Use only LPG (Liquefied Petroleum Gas) as specified. Ensure the gas cylinder is placed upright and secured.
- Leak Checks: Before each use, check all gas connections for leaks using a soapy water solution. Never use an open flame to check for leaks.
- Zvishandiso zvinopisa: Keep the heater at a safe distance from all flammable materials (e.g., paper, fabric, wood, chemicals). Maintain a minimum clearance of 1 meter (3 feet) from the front and sides.
- Vana uye Zvipfuwo: Chengeta vana nezvipfuyo kure nehita panguva yekushanda uye panguva yekutonhora kwayo.
- Kutarisira: Usambofa wakasiya hita isina kutariswa ichiri kushanda.
- Magetsi: Ensure the electrical supply matches the specifications on the heater's rating label. Do not use damaged power cords.
- Kubata: Do not move the heater while it is operating or hot. Allow it to cool completely before handling or storing.
- Zvakanatsiridzwa: Usachinje hita kana zvikamu zvayo. Shandisa zvikamu zvepakutanga chete.
3. Package Zviri mukati
Carefully unpack the heater and check for any damage. Ensure all components are present:
- Geko G80410 Gas Heater Unit
- Gas Hose with Pressure Reducer
- Power Cable
- Mushandisi Chinyorwa (gwaro iri)

Mufananidzo 3.1: The included gas hose with an integrated pressure reducer, essential for connecting the heater to an LPG cylinder.
4. Setup
Follow these steps to set up your Geko G80410 gas heater:
- Kuiswa: Position the heater on a stable, level, non-combustible surface in a well-ventilated area. Ensure adequate clearance from walls and flammable materials as per safety guidelines.
- Connect Gas Hose:
- Connect one end of the gas hose (with the pressure reducer) to your LPG cylinder. Ensure a tight, secure connection.
- Batanidza rimwe divi repaipi yegesi kune gasi rinopinda riri pahita. Simbisa zvakasimba.
- Leak Test: After connecting the gas hose, perform a leak test. Apply a soapy water solution to all gas connections. If bubbles appear, there is a leak. Tighten connections or replace faulty parts. Do not proceed until all leaks are resolved.
- Batanidza Simba: Plug the power cable into a suitable grounded electrical outlet.

Mufananidzo 4.1: Side view of the heater, showing the connection points for the gas hose and the power cable. The robust handle on top facilitates transport.

Mufananidzo 4.2: Rear view of the Geko G80410 heater, highlighting the power cable connection point and the fan intake grill.
5. Operating Instructions
Before operating, ensure all safety precautions and setup steps have been followed.
- Kupa Gasi Rakavhurika: Slowly open the valve on the LPG cylinder.
- Power On: Flip the main power switch (often labeled 'I/O' or 'ON/OFF') on the control panel to the 'ON' position. The fan should start running.
- Open Gas Valve on Heater: Press and hold the red 'Gas Valve' button on the control panel.
- Batidza: While holding the 'Gas Valve' button, press the 'Ignition' button repeatedly until the flame ignites. You should hear a clicking sound and see the flame through the front grill.
- Release Gas Valve: Once the flame is stable, continue to hold the 'Gas Valve' button for approximately 10-15 seconds to allow the thermocouple to heat up, then slowly release it. The heater should continue to operate. If the flame extinguishes, repeat steps 3-5.
- Vhara: To turn off the heater, first close the valve on the LPG cylinder. Allow the heater to run until the flame extinguishes (this clears any remaining gas from the hose). Then, turn off the main power switch on the heater.

Mufananidzo 5.1: Pedyo-up view of the control panel, clearly showing the red 'Ignition' button and the red 'Gas Valve' button, along with the main power switch.
6. Kuchengeta
Kugadziriswa nguva dzose kunovimbisa kugara kwenguva refu uye kushanda kwakachengeteka kweheater yako.
- Kuchenesa: Ensure the heater is completely cool and disconnected from power and gas before cleaning. Wipe the exterior with a damp cloth. Do not use abrasive cleaners or solvents. Keep the air intake and exhaust grills clear of dust and debris.
- Gas Hose and Connections: Periodically inspect the gas hose for cracks, cuts, or wear. Check all connections for tightness. Replace any damaged components immediately.
- Kuchengeta: Kana usiri kushandisa, bvisa silinda yegesi wochengeta hita yacho munzvimbo yakaoma, isina guruva, kure nezuva rakananga uye tembiricha dzakanyanya.

Mufananidzo 6.1: Mberi view of the heater, showing the protective grill and the internal fan, which should be kept clear of obstructions for optimal performance.
7. Kugadzirisa matambudziko
Kana ukasangana nematambudziko, tarisa kune anotevera akajairika matambudziko uye mhinduro:
- Heater does not ignite:
- Check if the LPG cylinder valve is open.
- Ensure the gas hose connections are secure and there are no leaks.
- Verify the main power switch is ON and the fan is running.
- Ensure the 'Gas Valve' button is pressed and held while attempting ignition.
- Tarisa kana silinda yegesi isina chinhu.
- Flame extinguishes after releasing 'Gas Valve' button:
- Ensure you held the 'Gas Valve' button for 10-15 seconds after ignition to allow the thermocouple to heat up.
- The thermocouple might be dirty or faulty. Contact qualified service personnel.
- Low heat output:
- Check the gas supply and ensure the cylinder is not running low.
- Ensure the heater is not obstructed and has proper ventilation.
For problems not listed here or if troubleshooting steps do not resolve the issue, contact qualified service personnel or the manufacturer.
8. Zvinotsanangurwa
| Model Number | G80410 |
| Mugadziri | Firma Handlowa GEKO |
| Power Output | 15 kW |
| Fuel Type | LPG (Liquefied Petroleum Gas) |
| Zviyero zveChigadzirwa (L x W x H) | 474 x 183 x 307 mm |
| Package Dimensions | 35 x 35 x 15 cm |
| Package Weight | 14.5 kg |
| Nyika Yekwakabva | Porendi |
9. Warranty uye Tsigiro
For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your proof of purchase for warranty claims.