VOLTCRAFT LWT-100

VOLTCRAFT LWT-100 (TDS) Conductivity Meter User Manual

Model: LWT-100

1. Chigadzirwa Pamusoroview

The VOLTCRAFT LWT-100 is a high-quality conductivity meter designed for rapid determination of conductivity, salinity, and Total Dissolved Solids (TDS) values in various liquids. Featuring a superior graphite measuring cell and IP67 water resistance, this device ensures accurate and reliable measurements in demanding environments.

Mberi view of the VOLTCRAFT LWT-100 Conductivity Meter showing its digital display and control buttons.

Mufananidzo 1: Mberi view of the LWT-100 Conductivity Meter. The device features a clear digital display showing conductivity and temperature readings, along with intuitive control buttons for navigation.

2. Safety Information

Please read and understand all safety instructions before operating the device. Failure to do so may result in injury or damage to the meter.

  • Do not immerse the entire device in water beyond its IP67 rating. The measuring cell is designed for liquid contact, but the main body should be protected from excessive moisture.
  • Avoid dropping the device or subjecting it to severe impacts.
  • Usaedza kuvhura kana kugadzirisa mudziyo. Tumira masevhisi ese kuvashandi vanokwanisa.
  • Chengetedza pasingasvikirwi nevana.
  • Clean the measuring cell carefully as described in the Maintenance section.

3. Zvigadzirwa zveChigadzirwa

The VOLTCRAFT LWT-100 package typically includes:

  • 1 x VOLTCRAFT LWT-100 Conductivity Meter
  • Mushandisi Chinyorwa (gwaro iri)
Back view of the VOLTCRAFT LWT-100 Conductivity Meter showing the product label with model and serial number.

Mufananidzo 2: Kudzoka view of the LWT-100 Conductivity Meter. The rear label provides essential product information, including the model name, measurement range, and serial number.

4. Setup

The VOLTCRAFT LWT-100 is designed for immediate use. It operates on an internal power source and does not require user-replaceable batteries. Follow these steps for initial setup:

  1. Kuburitsa: Carefully remove the meter from its packaging.
  2. Kutanga Kuongorora: Check the device for any visible damage. If damaged, do not use and contact customer support.
  3. Power On: Press the power button (usually indicated by a power symbol or a specific button on the front panel) to turn on the device. The display should illuminate.
  4. Kuzviedza: The device may perform a brief self-test upon startup. Wait for the display to show stable readings or a ready indicator.

5. Operating Instructions

The LWT-100 allows for quick and accurate measurement of conductivity, salinity, and TDS. Ensure the measuring cell is clean before each use.

Close-up of the VOLTCRAFT LWT-100 display showing a conductivity reading of 768 µS and a temperature of 23.4°C.

Figure 3: Close-up of the LWT-100 display. The screen clearly shows the measured conductivity in microSiemens (µS) and the corresponding temperature in degrees Celsius (°C).

5.1 Kutora Chiyero

  1. Gadzirira Sample: Ensure the liquid sample is at a stable temperature and free of large particles that could obstruct the sensor.
  2. Immerse Sensor: Carefully immerse the graphite measuring cell (located at the bottom of the device) into the liquid sample. Ensure the sensor is fully submerged and no air bubbles are trapped around it.
  3. Verenga Ratidza: Wait for the reading on the display to stabilize. The device will show the conductivity value (e.g., in µS/cm or mS/cm) and the temperature.
  4. Rekodha Data: Note down the measured values as needed.
  5. Kuchenesa Sensor: After each measurement, rinse the measuring cell with distilled or deionized water to prevent contamination and residue buildup.

5.2 Changing Measurement Modes (if applicable)

The LWT-100 can measure conductivity, salinity, and TDS. Use the designated mode button (refer to the button labels on your device, typically indicated by an arrow or 'MODE' symbol) to cycle through the available measurement modes. The active mode will be indicated on the display.

6. Kuchengeta

Proper maintenance ensures the longevity and accuracy of your VOLTCRAFT LWT-100.

  • Cleaning the Measuring Cell: After each use, rinse the graphite measuring cell thoroughly with distilled or deionized water. For stubborn residues, gently wipe the electrodes with a soft, lint-free cloth. Do not use abrasive materials or harsh chemicals.
  • Kuchenesa Muviri Wechishandiso: Pukuta kunze kwemudziyo nekanyoro, damp jira. Usashandise zvinonyungudutsa kana mishonga yakasimba.
  • Kuchengeta: Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the measuring cell is clean and dry before storage.
  • Calibration: While the LWT-100 is designed for high accuracy, periodic calibration with known conductivity standards may be required for critical applications. Refer to specific calibration instructions if provided with your device or consult VOLTCRAFT support.

7. Kugadzirisa matambudziko

If you encounter issues with your LWT-100, refer to the following common problems and solutions:

DambudzikoZvinogona KukonzeraSolution
Chigadzirwa hachishandi.Internal power source depleted or fault.Ensure the power button is pressed firmly. If the issue persists, contact customer support.
Kuverenga kusina kururama kana kuti kunochinja-chinja.Dirty measuring cell; air bubbles around sensor; sample contamination; sensor damage.Clean the measuring cell thoroughly. Gently tap the device to dislodge air bubbles. Use a fresh, clean sample. If problem persists, sensor may be damaged; contact support.
Chiratidziro chinoratidza meseji yemhosho.Out of range measurement; internal fault.Iva nechokwadi chekuti sample's conductivity is within the device's specified range. Turn the device off and on again. If the error persists, contact customer support.

8. Zvinotsanangurwa

FeatureTsanangudzo
Model Number1720718 (VC-8603590)
MugadziriVOLTCRAFT
Dimensions (L x W x H)2.8 x 5.4 x 10.8 cm
Kurema200 magiramu
Ingress Dziviriro (IP) RatingIP67 (isina mvura)
Measuring Cell TypeHigh-quality Graphite
Simba SourceInternal (Manually Powered)
Nyika YekwakabvaJerimani

9. Ruzivo Rwekutsigira

For technical support, warranty claims, or spare parts availability, please contact VOLTCRAFT customer service. Refer to the official VOLTCRAFT websaiti kana magwaro ekutenga kwako kuti uwane ruzivo.

Kuwanikwa kwezvikamu zvekuchengetedza: Gore rimwe.

Related Documents - LWT-100

Preview VOLTCRAFT VC-1320 AC TRMS Leakage Clamp Meter - Technical Datasheet
Detailed technical specifications and features for the VOLTCRAFT VC-1320 AC TRMS Leakage Clamp Meter, including measurement ranges, accuracy, safety ratings, and package contents.
Preview VOLTCRAFT VC-1320 AC TRMS Áramszivárgás-mérő Fogó Használati Útmutató
Részletes használati útmutató a VOLTCRAFT VC-1320 AC TRMS Áramszivárgás-mérő Fogóhoz, amely tartalmazza a funkciókat, biztonsági utasításokat, kezelést és műszaki adatokat.
Preview VOLTCRAFT VC-BT300PRO OBDII + Batterietester Bedienungsanleitung
Umfassende Bedienungsanleitung für den VOLTCRAFT VC-BT300PRO, ein Diagnosewerkzeug für OBD-II und Batterietests. Enthält Funktionen, Sicherheitshinweise und technische Daten.
Preview VOLTCRAFT VC-513 80A AC/DC Stromzange Bedienungsanleitung
Umfassende Bedienungsanleitung für die VOLTCRAFT VC-513 80A AC/DC Stromzange. Erfahren Sie mehr über sichere Bedienung, Messverfahren für Strom, Spannung, Widerstand und mehr, sowie technische Spezifikationen.
Preview VOLTCRAFT Digital Multimeters VC-7060BT & VC-7200BT User Manual
Comprehensive user manual for VOLTCRAFT VC-7060BT and VC-7200BT digital multimeters, covering safety, operation, functions, measurement tutorials, troubleshooting, and technical specifications.
Preview Bhuku reVashandisi veVoltCRAFT MF-100 Moisture Meter uye Magadzirirwo eTechnical
Mirayiridzo yakadzama yekushandisa, nhungamiro dzekuchengetedza, zvirevo zvehunyanzvi, uye ruzivo rwekuraswa kwemuchina weVOLTCRAFT MF-100 wemvura. Dzidza kuyera hunyoro nemazvo muzvinhu zvakasiyana-siyana zvekuvaka.