This manual provides essential information for the installation, operation, maintenance, and troubleshooting of the IHP OEM Superior Pilot Assembly, model H2328, designed for natural gas (NG) fireplaces, stoves, and inserts. This is an original equipment manufacturer (OEM) part, ensuring compatibility and performance with specified IHP and Lennox models.

IHP OEM Superior Pilot Assembly - NG (H2328)

An image showing the IHP OEM Superior Pilot Assembly for natural gas fireplaces and stoves. The assembly includes the pilot burner, thermocouple, and igniter, with copper tubing coiled above.

Zvinokosha:

Kugarisana

The IHP OEM Superior Pilot Assembly (H2328) is a direct replacement for Lennox part number 901047 and is compatible with the following Lennox / IHP Gas Fireplace Models:

Always verify compatibility with your specific appliance model before installation.

Setup uye Installation

Installation of gas appliance components should only be performed by a qualified service technician. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.

Matanho Ekuisa Kazhinji (kune mainjiniya vane hunyanzvi):

  1. Chengetedzo Kutanga: Ensure the gas supply to the appliance is turned off and the appliance is completely cool. Disconnect electrical power if applicable.
  2. Access the Pilot Assembly: Carefully remove any panels or components necessary to access the existing pilot assembly within the fireplace or stove.
  3. Disconnect Old Assembly: Disconnect the gas line, thermocouple, and igniter wires from the old pilot assembly. Note their positions for reinstallation.
  4. Bvisa Musangano Wekare: Unfasten and remove the old pilot assembly from its mounting bracket.
  5. Isa Musangano Mutsva: Mount the new IHP OEM Superior Pilot Assembly (H2328) into the designated position, ensuring it is securely fastened.
  6. Batanidza Zvikamu: Reconnect the gas line, thermocouple, and igniter wires to the new assembly. Ensure all connections are tight and secure. Use new gaskets if provided.
  7. Leak Test: After reassembly, turn on the gas supply and perform a leak test on all connections using an approved leak detection solution.
  8. Test Operation: Restore electrical power (if applicable) and test the appliance's ignition and pilot light operation according to the appliance's specific instructions.

Refer to your specific fireplace or stove's service manual for detailed, model-specific installation instructions and safety precautions.

Operating Principles

The pilot assembly is a critical component in the ignition and safety system of your natural gas fireplace or stove. While it does not have direct user controls, understanding its function is important.

Proper operation of the pilot assembly ensures safe and reliable ignition of your gas appliance.

Maintenance

Regular inspection and maintenance of your pilot assembly can help ensure the longevity and safe operation of your gas appliance. Maintenance should be performed by a qualified service technician.

Recommended Maintenance:

Always ensure the appliance is cool and the gas supply is off before any inspection or cleaning.

Kugadzirisa matambudziko

If your gas appliance is experiencing issues related to ignition or pilot light operation, the pilot assembly may be a factor. Always consult a qualified service technician for diagnosis and repair.

Matambudziko Anowanikwa uye Zvikonzero Zvingangoitika:

DambudzikoChinogona KukonzeraAction (for qualified technician)
Pilot light won't light.No gas supply, clogged pilot orifice, faulty igniter, faulty gas valve.Check gas supply, clean orifice, test/replace igniter, inspect gas valve.
Pilot light lights but won't stay lit.Weak pilot flame, faulty thermocouple/thermopile, loose connections.Adjust pilot flame, test/replace thermocouple, tighten connections.
Main burner won't ignite after pilot lights.Faulty main gas valve, insufficient pilot flame to ignite main burner.Test main gas valve, adjust pilot flame, ensure proper pilot alignment.
Soot or carbon buildup around pilot.Improper air/gas mixture, dirty pilot orifice.Clean pilot, adjust air shutter (if applicable), check gas pressure.

Do not attempt to repair gas components yourself. Always contact a certified gas technician for any troubleshooting or repairs.

Zvinotsanangurwa

AttributeDetail
Model NumberH2328
Chikamu TypePilot Assembly (OEM)
Fuel TypeGasi Rakasikwa (NG)
BrandIHP (Innovative Hearth Products)
Inotsiva Chikamu NhambaLennox 901047
Item Weight2 makirogiramu
Package Dimensions8 x 5 x 4 inches
ColorBlack (referring to components, not overall assembly color)

Warranty Information

As an OEM (Original Equipment Manufacturer) part, this IHP pilot assembly is typically covered by the original manufacturer's warranty for replacement parts. Warranty terms can vary based on the manufacturer and the point of purchase.

For specific warranty details, please refer to the documentation provided with your original fireplace or stove, or contact IHP (Innovative Hearth Products) directly. Keep your proof of purchase for any warranty claims.

Mutengi Support

For technical assistance, installation questions, or service, it is highly recommended to contact a qualified HVAC or gas appliance technician. They have the expertise and tools to safely diagnose and repair issues related to gas components.

You may also visit the official IHP (Innovative Hearth Products) website for product information and authorized service provider locators. When contacting support, please have your appliance model number and the pilot assembly model number (H2328) ready.

Chiziviso Chakakosha Chekuchengetedza: Never attempt to modify or repair gas components if you are not a qualified professional. Doing so can result in serious injury, property damage, or death.

Related Documents - H2328

Preview IHP Rigid Firescreen Kits Installation Instructions
Installation instructions for IHP Rigid Firescreen Kits, including models BNZN and BUCEBWZN, compatible with Ladera, BIS Nova, Brentwood SP, Montecito, and BIS Ultima-1 fireplaces. Learn how to safely install and use your firescreen.
Preview Superior Fireplaces DRI3030TEN & DRI2530TEN Bhuku reMuridzi uye Kuisa Gwaro
Iri bhuku rakazara remuridzi uye yekumisikidza dhairekitori rinopa ruzivo rwakakosha kune Superior Fireplaces DRI3030TEN uye DRI2530TEN yakananga-vent-vent gasi moto inoisa, yekuvharisa kuisirwa, kushanda, kuchengetedza, uye kugadzirisa.
Preview Innovative Hearth Products Facade Kit Installation Instructions
Detailed installation instructions for the Innovative Hearth Products Facade Kit, designed for Astria CompassDLX, Compass Series, and Superior DRL2000/DRL3500 Series DV Linear Fireplaces. Includes packaging list, tools needed, and step-by-step assembly guidance.
Preview 5G Internet Gedhi Kunze Kwekukwira Kit Kuisa Gwaro | LV55IHP
Yepamutemo yekuisa gwara reVerizon 5G Internet Gateway Kunze Kukwidza Kit (Modhi LV55IHP). Dzidza nzira yekuisa, yekubatanidza, uye kugadzirisa mudziyo wako uine mirairo yakadzama uye zvakatemwa.
Preview Superior WCT6920WSS Wood-Burning Fireplace Installation and Operation Manual
Comprehensive installation and operation manual for the Superior WCT6920WSS wood-burning fireplace by Innovative Hearth Products. Covers safety precautions, installation steps, operation, maintenance, specifications, and warranty information.
Preview Mahita eGas Log Asina Kuvhurwa (Asina Kubuda Nemhepo) Ane Simba: Bhuku Rekushandisa Nekuisa
Gwaro rakakwana rekuisa nekushandisa maHigher brand Unvented (Asina Maburi) Gas Log Heaters, kusanganisira yambiro dzekuchengetedza, marongero emhando, uye mazano ekugadzirisa matambudziko.