This manual provides essential information for the installation, operation, and maintenance of your Lunos e² decentralized ventilation system. Please read this manual thoroughly before installation and operation to ensure proper function and safety. Keep this manual for future reference.

The Lunos e² system is a highly efficient, decentralized ventilation unit with heat recovery, designed for room-by-room ventilation. It operates on a reversible airflow principle using a ceramic regenerator, ensuring low energy consumption and quiet operation.

Zvigadzirwa Zvikamu

Yakaputika view of Lunos e² ventilation unit components and accessories

Mufananidzo 1: Yakaputika view of the Lunos e² decentralized ventilation units and accompanying accessories. This image shows two complete ventilation units, two round ducts, a universal control unit, a power supply, and a wall switch. Each ventilation unit consists of an outer grille, a fan, a ceramic heat exchanger, and an inner panel with a filter.

The Lunos e² system includes:

Setup uye Installation

Installation should be performed by a qualified professional. Ensure all local building codes and regulations are followed.

Pre-installation Checks:

Kuisa Matanho:

  1. Drill a 162 mm diameter hole through the wall at the desired location, ensuring a slight downward slope to the outside for drainage.
  2. Insert the round duct (DN160 mm) into the drilled hole. Cut the duct to the appropriate length for the wall thickness.
  3. Install the Lunos e² ventilation unit into the duct. Ensure the ceramic heat exchanger and fan are correctly oriented.
  4. Mount the exterior grille (1-WE 180) on the outside of the wall, securing it with screws.
  5. Mount the interior panel with filter (9/IBE) on the inside of the wall.
  6. Connect the ventilation units to the 5/UNI-FT universal control unit.
  7. Connect the 5/NT18 power supply to the universal control unit and to the main power.
  8. Install the 5/W2U switch in a convenient location and connect it to the universal control unit.

Operating Instruction

The Lunos e² system is designed for continuous operation to maintain optimal indoor air quality and heat recovery.

Basic Operation:

Maitiro Okushandisa:

The Lunos e² system typically offers multiple fan speed settings to adjust ventilation rates:

The system also features humidity recovery, typically around 20-30%, to prevent excessive drying of indoor air during colder months.

Maintenance

Regular maintenance ensures optimal performance and longevity of your Lunos e² ventilation system.

Filter Replacement/Cleaning:

The G3 filter should be checked regularly and replaced or cleaned as needed, typically every 3-6 months depending on air quality.

  1. Turn off the ventilation system at the main switch.
  2. Carefully remove the interior panel.
  3. Remove the G3 filter.
  4. Clean the filter by vacuuming or gently washing with warm water (if washable type). Allow to dry completely before reinstallation. Replace if heavily soiled or damaged.
  5. Reinsert the clean/new filter and reattach the interior panel.
  6. Turn the system back on.

Ceramic Heat Exchanger Cleaning:

The ceramic heat exchanger should be cleaned annually or if performance degrades.

  1. Turn off the ventilation system.
  2. Remove the interior panel and filter.
  3. Carefully pull out the ceramic heat exchanger unit.
  4. Clean the ceramic core under running water. Do not use harsh detergents. Allow to dry completely.
  5. Reinsert the dry ceramic heat exchanger, ensuring correct orientation.
  6. Reinstall the filter and interior panel.
  7. Turn the system back on.

Exterior Grille Cleaning:

Periodically inspect and clean the exterior grille to ensure unobstructed airflow.

Kugadzirisa matambudziko

If you experience issues with your Lunos e² system, consult the following table before contacting support.

DambudzikoZvinogona KukonzeraSolution
System not operatingNo power supply; switch is OFF.Check power connection; ensure switch is ON. Verify power supply (5/NT18) is functioning.
Reduced airflow or efficiencyClogged filter; dirty ceramic heat exchanger; obstructed exterior grille.Clean or replace filter; clean ceramic heat exchanger; clear any obstructions from the exterior grille.
Ruzha rusina kujairikaFan obstruction; kusununguka zvikamu.Turn off system and inspect fan for obstructions. Ensure all components are securely installed. If noise persists, contact support.
Condensation around unitImproper installation (e.g., no downward slope); extreme temperature difference.Ensure proper installation with slight downward slope. If problem persists, consult a professional.

Zvinotsanangurwa

Detailed technical specifications for the Lunos e² decentralized ventilation system.

Lunos e² Energy Label

Mufananidzo 2: Energy label for the Lunos e² ventilation system, indicating an A+ energy efficiency rating, 40 dB sound level, and a maximum airflow of 38 m³/h.

Lunos e² Product Data Sheet

Mufananidzo 3: Product data sheet for the Lunos e² ventilation system, detailing specifications such as supplier, model identification, specific energy consumption, type of heat recovery, thermal efficiency, maximum flow rate, power input, sound pressure level, and annual energy consumption.

ParameterValue
ModelLunos e²
Heat Recovery Efficiency90.6%
Airflow Volume (m³/h)18 / 31 / 38
Power Consumption per unit (W)1.4 / 2.8 / 3.3
Rated Power (W/m³/h)0.09
Network Voltage12 V DC
Humidity RecoveryApprox. 20-30%
Ruzha rwekumanikidza Chikamu (dB)16.5 / 19.5 / 26
Normal Sound Level (DN,W, open)42 dB
Unit Length243 mm
Minimum Wall Thickness300 mm
Hole Diameter162 mm

Warranty uye Support

For warranty information, please refer to the documentation provided with your purchase or contact Lunos directly. Keep your proof of purchase for warranty claims.

For technical support, spare parts, or further assistance, please contact Lunos customer service. Contact details can typically be found on the manufacturer's official websaiti kana painvoice yako yekutenga.

Mugadziri: Lunos

Websaiti: www.lunos.de

Related Documents - localization_B07MQ62LLD

Preview Bhuku reKuisa Sisitimu Yekufema Yakaganhurirwa yeLUNOS Nexxt
Gwaro rakakwana rekuisa system yeLUNOS Nexxt decentralized ventilation ine kudzoreredza kupisa, inosanganisira hunyanzvi hwekugadzira, kuisa, kubatana kwemagetsi, magadzirirwo eDIP switch, kutsiva firita, uye kugadzirisa.
Preview Bhuku Rekuisa Sisitimu Yekufema YeLunos e² Series
Bhuku rekushandisa rekuisa system yeLUNOS e² Series ine mwero wekupisa. Rinosanganisira hunyanzvi hwekugadzira, madhayagiramu ekubatanidza magetsi, uye gwara rekuisa.
Preview LUNOS Series e² Decentralized Ventilation System ine Heat Recovery - Kuisa Manual
Yakakwana yekuisa bhuku reLUNOS Series e² decentralized ventilation system ine kupisa kudzoreredza. Inovharira ruzivo rwechigadzirwa, zvehunyanzvi, kubatanidza magetsi, mirau yekuisa, uye kugadzirisa kwemhando dzakaita see², e²kurz, e²60, uye e²60kurz.
Preview LUNOS 5/UNI-FT & 5/UNI-RF Universal Control Installation Manual
Bhuku rekushandisa rekuisa system yeLUNOS 5/UNI-FT uye 5/UNI-RF Universal Control, maficha anotsanangura, hunyanzvi, kubatana kwemagetsi, magadzirirwo ekuchinjana makodhi, uye nzira dzekushandisa masisitimu ekufema.
Preview LUNOS Universal Controller 5/UNI-FT Settings Guide
Nhungamiro yakazara yeLUNOS Universal Controller (Typ: 5/UNI-FT, No.:40269), inovhara maficha, tekinoroji maratidziro, magetsi ekubatanidza, dial marongero, uye yekubata mirairo yekunyatso fambisa mhepo yekufemesa system.
Preview Gwaro reKUVHURA KWEMHEPO YEKUPENYA KWEMOTO YELUNOS: Zvinokonzera uye Mhinduro
Gwaro rakakwana kubva kuLUNOS pamusoro pekunzwisisa, kudzivirira, uye kuderedza kunyorova kwemvura pamadziro emukati mezvishandiso zvemhepo zvinofefetedza mumba. Dzidza nezvezvikonzero zvakaita sehunyoro hunoramba huripo uye maitiro ekuchengetedza hunyoro hwakakwana mumba.