Apera Instruments AI531

Apera Instruments PH820 Benchtop pH Meter Kit

Bhuku reMirayiridzo

Product Overview

The Apera Instruments PH820 Benchtop pH Meter Kit is designed for reliable and accurate pH measurements in laboratory settings. It features advanced functionalities including intelligent calibration, data management, and a durable, water-resistant structure. This manual provides detailed instructions for proper use and care of your PH820 meter.

Apera Instruments PH820 Benchtop pH Meter Kit with electrode and stand

Figure 1: Apera Instruments PH820 Benchtop pH Meter Kit, showing the main unit, electrode, temperature probe, and electrode arm.

Key features of the PH820 include:

Gadzirira

Kusunungura uye Kuongorora kweChikamu

Carefully unpack all components from the kit. Verify that the following items are present:

Kubatanidza Zvikamu

Connect the electrode, temperature probe, and power adapter to the corresponding ports on the back of the PH820 meter unit. Ensure all connections are secure.

Back panel of Apera Instruments PH820 pH meter showing connection ports

Mufananidzo 2: Kumashure view of the PH820 meter, highlighting the REF, pH/mV, TEMP, RS232, and DC 9V input ports.

  1. Electrode Connection: Plug the LabSen 211 pH Electrode into the port labeled "pH/mV".
  2. Temperature Probe Connection: Insert the temperature probe into the port labeled "TEMP".
  3. Power Connection: Connect the power adapter to the "DC 9V" port and then to a power outlet.
  4. Electrode Arm Assembly: Attach the flexible electrode arm and holder to the side of the meter unit for convenient electrode placement during measurements.

Operating Instruction

Basic pH Measurement

  1. Power on the meter by pressing the power button.
  2. Rinse the electrode with distilled water and gently blot dry.
  3. Immerse the electrode and temperature probe into the sample solution. Ensure the electrode tip is fully submerged.
  4. Wait for the reading on the large LCD to stabilize. The meter displays pH and temperature simultaneously.
  5. Nyora kuverenga kwakagadzikana.

pH Kuchengetedza

The PH820 supports 1 to 5 points automatic calibration. Regular calibration ensures measurement accuracy.

  1. Prepare the standard calibration solutions (4.00 pH, 7.00 pH, 10.01 pH are included).
  2. Press the CAL bhatani rekupinda mu calibration mode.
  3. Rinse the electrode and immerse it into the first calibration solution (e.g., 7.00 pH).
  4. The meter will automatically recognize the solution and begin calibration. Wait for the stability icon to appear.
  5. Once stable, the meter will prompt for the next calibration point. Repeat the rinsing and immersion process for subsequent solutions.
  6. The self-diagnosis function will provide feedback on the calibration process and electrode condition, including slope data.
  7. Exit calibration mode once all desired points are completed.

Data Management

The PH820 allows for GLP data management, storing up to 500 groups of data. Data can be output via USB to a PC using the provided PC-Link software (Windows-based system only). Auto-timing data logging can also be configured.

ORP Measurement (Optional)

The PH820 can measure Oxidation-Reduction Potential (ORP) when an ORP electrode (e.g., 301Pt-C, sold separately) is connected to the pH/mV port. Refer to the ORP electrode's specific instructions for calibration and measurement procedures.

Maintenance

Electrode Care

Proper care of the LabSen 211 pH Electrode is crucial for maintaining accuracy and extending its lifespan.

Close-up of the LabSen 211 pH electrode

Mufananidzo 3: Pedyo-kumusoro view of the LabSen 211 pH Electrode, showing its glass body and sensor tip.

Meter Care

The PH820 meter unit is IP54 water-resistant, meaning it is protected from dust and splashing water. However, it should not be submerged. Keep the meter clean and dry. Use a soft, damp cloth to wipe the surface. Avoid using abrasive cleaners or solvents.

Kugadzirisa matambudziko

The PH820 features a self-diagnosis function that can assist in identifying and fixing common problems, particularly during calibration. Refer to the meter's display for diagnostic messages.

DambudzikoZvinogona KukonzeraSolution
Unstable ReadingsDirty electrode; air bubbles; insufficient sample volume; expired calibration.Clean electrode; ensure no bubbles; use adequate sample; recalibrate.
Calibration KukundikanaIncorrect buffer solution; contaminated electrode; electrode aging.Use fresh, correct buffers; clean electrode; check electrode slope data (self-diagnosis) for replacement indication.
No Display/PowerPower adapter issue; loose connection.Check power adapter and outlet; ensure all cables are securely connected.
Kuverenga Kusina KurongekaElectrode not calibrated; temperature not compensated; damaged electrode.Perform calibration; ensure temperature probe is functioning; inspect electrode for damage.

For persistent issues not resolved by the above, please contact Apera Instruments customer support.

Zvinotsanangurwa

ParameterValue
Model NumberAI531
pH Kururama±0.002 pH±1 digit
Calibration Points1 to 5 points (Auto.)
Data Storage500 groups (GLP compliant)
Data OutputUSB (PC software support)
Kuramba MvuraIP54
Power Input120V AC 60Hz
Power Output9V 300mA
Package Dimensions10.67 x 10.2 x 6.65 inches
Kurema6.69 Pondo
CertificationsCE, RoHS, ISO 9001:2015

Warranty uye Support

Apera Instruments products are manufactured under an ISO 9001:2015 certified quality system, ensuring high standards of production. For specific warranty information and technical support, please refer to the warranty card included with your product or visit the official Apera Instruments website. You may also contact their customer service directly for assistance with product operation, troubleshooting, or parts replacement.