VOLTCRAFT TP-202

VOLTCRAFT TP-202 Type K Air Sensor Instruction Manual

Model: TP-202 (VC-8307380)

1. Nhanganyaya

The VOLTCRAFT TP-202 is a Type K thermocouple air sensor designed for accurate temperature measurement in various applications. This sensor is capable of measuring temperatures ranging from 0 to 250 °C and features a standard thermocouple connector for compatibility with a wide range of measurement devices. This manual provides essential information for the safe and effective use of your TP-202 sensor.

2. Safety Information

Please read and understand all safety instructions before using the VOLTCRAFT TP-202 sensor. Failure to follow these instructions may result in injury or damage to the product.

  • Temperature Limits: Do not expose the sensor to temperatures outside its specified range of 0 to 250 °C. Exceeding these limits can damage the sensor and lead to inaccurate readings.
  • Kuchengetedzwa Kwemagetsi: While the sensor itself is passive, ensure that any connected measurement device is properly grounded and used according to its own safety guidelines. Avoid contact with live electrical circuits.
  • Kukuvadza Pamuviri: Handle the sensor and its cable with care. Do not bend the cable sharply or apply excessive force to the connector or probe tip.
  • Zvinotarisirwa Kushandiswa: This sensor is designed for air temperature measurement. Do not use it for measuring corrosive liquids or in environments where it may be exposed to physical stress beyond its design.

3. Chigadzirwa Pamusoroview

The VOLTCRAFT TP-202 Type K Air Sensor consists of a sensing element at the end of a flexible blue cable, terminated with a standard Type K thermocouple connector. This connector ensures compatibility with a wide range of digital thermometers and multimeters that support Type K thermocouples.

VOLTCRAFT TP-202 Type K Air Sensor with blue cable and yellow connector

Figure 3.1: The VOLTCRAFT TP-202 Type K Air Sensor features a standard thermocouple connector and a blue cable leading to the sensing element.

4. Zvinotsanangurwa

TsanangudzoValue
MugadziriVOLTCRAFT
Model NumberVC-8307380
Sensor TypeTora K Thermocouple
Temperature Range0 kusvika 250 °C
Cable Length1 mita
Connector TypeStandard Thermocouple (Plug-in)
Zviyero zveChigadzirwa (L x W x H)14 x 11 x 3 cm
Kurema20 magiramu
Simba SourceRequires external measurement device
Zvikamu Zvinosanganisirwa1 chidimbu
Mabhatiri AnodiwaNo (for sensor)
Nyika YekwakabvaJerimani
Technical drawing of VOLTCRAFT TP-202 Type K Air Sensor with dimensions

Figure 4.1: Technical diagram illustrating the dimensions and structure of the VOLTCRAFT TP-202 sensor.

5. Setup

To set up your VOLTCRAFT TP-202 Type K Air Sensor:

  1. Prepare Measurement Device: Ensure your digital thermometer or multimeter is compatible with Type K thermocouples and is set to the appropriate measurement mode (e.g., °C or °F).
  2. Connect Sensor: Carefully insert the yellow Type K thermocouple connector of the TP-202 sensor into the corresponding Type K input jacks on your measurement device. Ensure the polarity is correct (the wider pin typically connects to the negative terminal, and the narrower pin to the positive, though Type K connectors are usually keyed to prevent incorrect insertion).
  3. Secure Connection: Ensure the connection is firm and stable to prevent intermittent readings.

6. Kushanda

Once the sensor is connected to a compatible measurement device:

  1. Power On: Turn on your measurement device.
  2. Position Sensor: Place the sensing element of the TP-202 in the air environment where you wish to measure the temperature. Ensure the probe is not in direct contact with surfaces that might skew the air temperature reading.
  3. Verenga kuyerwa: Allow a few moments for the reading to stabilize on your measurement device's display. The displayed value is the current air temperature at the sensor's location.
  4. Dzivisa kupindira: Keep the sensor and cable away from strong electromagnetic fields or heat sources that are not the target of measurement, as these can affect accuracy.
Hand holding a VOLTCRAFT thermometer with the TP-202 sensor measuring an air conditioning unit

Figure 6.1: The VOLTCRAFT TP-202 Type K Air Sensor connected to a compatible handheld thermometer, measuring the temperature of an air conditioning unit.

7. Kuchengeta

Proper maintenance ensures the longevity and accuracy of your sensor:

  • Kuchenesa: Gently wipe the sensor probe and cable with a soft, dry cloth. If necessary, use a slightly damp cloth with mild soap, then dry thoroughly. Do not use abrasive cleaners or solvents.
  • Kuchengeta: Store the sensor in a clean, dry environment, away from extreme temperatures and direct sunlight. Coil the cable loosely to prevent kinks or damage.
  • Kuongorora: Periodically inspect the cable and connector for any signs of wear, cuts, or damage. Damaged sensors should be replaced to ensure accurate and safe operation.

8. Kugadzirisa matambudziko

If you encounter issues with your VOLTCRAFT TP-202 sensor, consider the following:

  • Hapana Kuverenga kana Kuverenga Zvisina Kunaka:
    • Check if the sensor is securely connected to the measurement device.
    • Ensure the measurement device is set to the correct Type K thermocouple mode.
    • Inspect the sensor cable and connector for any visible damage.
    • Verify that the measurement device itself is functioning correctly by testing with another known good sensor if available.
  • Kuverenga Kusina Kurongeka:
    • Ensure the sensor is placed correctly in the air environment and not influenced by other heat sources or drafts.
    • Allow sufficient time for the reading to stabilize.
    • Confirm the sensor is within its specified operating temperature range.
    • Consider if the measurement device requires calibration.

9. Warranty uye Tsigiro

The VOLTCRAFT TP-202 Type K Air Sensor comes with a 1-year spare parts availability. For technical support, warranty claims, or further assistance, please contact VOLTCRAFT customer service or refer to the support information provided with your measurement device.

For more information about VOLTCRAFT products, please visit the official VOLTCRAFT website.

Related Documents - TP-202

Preview Bhuku reVashandisi veVOLTCRAFT K101/K102 Digital Thermometer
Bhuku rekushandisa remathermometer edhijitari eVOLTCRAFT K101 neK102, maficha anotsanangura, mashandiro, gwara rekuchengetedza, uye hunyanzvi hwekuyera tembiricha nemazvo uchishandisa mathermocouple emhando yeK.
Preview Manuale d'uso Termometro Palmare Digitale VOLTCRAFT K101/K102
Istruzioni dettagliate per l'uso, la sicurezza, il funzionamento, la manutenzione e le specifiche tecniche per i termometri digitali VOLTCRAFT K101 e K102, progettati per misurazioni precise della temperatura con termocoppie di tipo K.
Preview VOLTCRAFT Digital Multimeters VC-7060BT & VC-7200BT User Manual
Comprehensive user manual for VOLTCRAFT VC-7060BT and VC-7200BT digital multimeters, covering safety, operation, functions, measurement tutorials, troubleshooting, and technical specifications.
Preview VOLTCRAFT VC-CJS10 1200A Jump Starter and Power Bank User Manual
User manual for the VOLTCRAFT VC-CJS10 1200A jump starter and power bank. Learn about its features, intended use, safety instructions, operation, and technical specifications for jump-starting vehicles and charging devices.
Preview Gwaro Rinokurumidza reVOLTCRAFT VC-7060BT & VC-7200BT reMadhijitari Multimeter
Gwaro rakakwana rinokurumidza reVOLTCRAFT VC-7060BT uye VC-7200BT digital multimeters. Dzidza nezvekuchengetedzeka, mashandiro, zviyero, uye kugadzirisa matambudziko.
Preview VOLTCRAFT VC-7060BT & VC-7200BT Digital Multimeters User Manual
This user manual provides comprehensive instructions for the VOLTCRAFT VC-7060BT and VC-7200BT digital multimeters. Learn about safety, measurement functions (voltage, current, resistance, etc.), advanced features like data logging and triggering, and detailed technical specifications for these CAT I/II rated instruments distributed by Conrad Electronic.