1. Nhanganyaya
Thank you for choosing the ANENG Q1 9999 Counts True RMS Digital Multimeter. This device is designed for safe and accurate measurement of various electrical parameters. It features True RMS measurement, Non-Contact Voltage (NCV) detection, auto/manual ranging, and an EBTN black display with an analog bar graph for enhanced readability. Please read this manual thoroughly before use to ensure proper operation and safety.
2. Safety Information
YAMBIRO: Kuti mudzivise kuvhundutswa nemagetsi, moto, kana kukuvara kwemunhu, ndapota verengai ruzivo rwese rwekuchengetedza musati mashandisa chigadzirwa ichi.
- Always ensure the multimeter is in the correct function and range for the measurement being performed.
- Usapfuure huwandu hwepamusoro hwezvinhu zvinopinzwa pabasa ripi zvaro.
- Tarisa matipi ekuyedza kuona kana paine chinhu chakakuvara kana simbi yakafumuka usati washandisa. Tsiva kana zvakakuvara.
- Do not use the multimeter if it appears damaged or if it is not operating properly.
- Chenjerera paunenge uchishanda nevoltages pamusoro pe30V AC RMS, 42V peak, kana 60V DC. Aya voltages inokonzeresa njodzi.
- Gara uchibvisa ma "test leads" kubva mu "circuit" usati wachinja mashandiro kana kuti "ranges".
- Replace batteries as soon as the low battery indicator appears to avoid incorrect readings.
- Omerera kune makodhi ekuchengetedza emunharaunda uye enyika.
3. Chigadzirwa Pamusoroview
The ANENG Q1 multimeter is a versatile tool for electrical measurements. Below is an image illustrating the device and its included accessories.

Image 3.1: ANENG Q1 Digital Multimeter and included accessories, including test leads, temperature probe, and storage bag.
The device features a large EBTN display, function buttons, and input jacks for test leads.

Mufananidzo 3.2: Mberi view of the ANENG Q1 Multimeter, highlighting the display, function buttons, and input terminals.
4. Setup
4.1 Kuiswa kwebhatiri
The ANENG Q1 multimeter requires two 1.5V AA batteries (not included). To install or replace batteries:
- Iva nechokwadi chekuti multimeter yadzimwa uye bvisa ma lead ese ekuyedza.
- Tsvaga chivharo chebhatiri kuseri kwemudziyo.
- Shandisa screwdriver kusunungura screw kuchengetedza chivharo.
- Bvisa chifukidziro woisa mabhatiri maviri eAA, uchicherechedza polarity chaiyo (+/-).
- Tsiva chivharo chekamuri yebhatiri uye simbisa screw.

Mufananidzo 4.1: Kumashure view of the multimeter, illustrating the battery compartment and the integrated kickstand.
4.2 Kubatanidza Miedzo Inotungamira
The multimeter comes with two standard test probes and a 16-in-1 multifunctional test line set. Always connect the black test lead to the COM (Common) jack. Connect the red test lead to the appropriate input jack based on the measurement type:
- VΩHz-+ jack for Voltage, Resistance, Frequency, Diode, and Continuity measurements.
- mA jack for milliampzviyero zvazvino.
- μA jack for microampzviyero zvazvino.
- 10A MAX jack for high current measurements (up to 10A).

Image 4.2: Included test leads and various accessories, such as alligator clips and fine-point probes.
5. Operating Instructions
The ANENG Q1 features both auto-ranging and manual-ranging capabilities. Press the CHIYERO button to switch between auto and manual modes. In manual mode, press CHIYERO repeatedly to cycle through available ranges.
5.1 Simba On/Kudzima
Dzvanya uye ubate iyo SIMBA button (red circle with line) for more than 2 seconds to turn the multimeter on or off. The device also features an Auto Power Off function to conserve battery life.
5.2 Kuyera AC/DC Voltage
- Unganidza iyo nhema bvunzo inotungamira kune iyo COM jack uye bvunzo dzvuku zvinotungamira kune VΩHz-+ jack.
- Turn on the multimeter. The device will typically default to auto-ranging voltage chiyero.
- Bata ma probes ekuyedza kusvika panzvimbo dzedunhu panowanikwa voltage inofanira kuyerwa.
- Verenga bhukutage value on the display. The multimeter automatically detects AC or DC voltage.
5.3 Measuring AC/DC Current
- ZVINOKOSHA: Ensure the circuit is de-energized before connecting the multimeter in series.
- Unganidza iyo nhema bvunzo inotungamira kune iyo COM jack. Batanidza mutsvuku wekuedza kutungamirira kune mA, μA, kana 10A MAX jack depending on the expected current.
- Insert the multimeter in series with the circuit where current is to be measured.
- Re-energize the circuit.
- Verenga kukosha kwazvino kuri pachiratidziro.
5.4 Kuyera Kupokana
- Unganidza iyo nhema bvunzo inotungamira kune iyo COM jack uye bvunzo dzvuku zvinotungamira kune VΩHz-+ jack.
- Iva nechokwadi chekuti dunhu kana chikamu chabviswa simba usati wayera kuramba.
- Touch the test probes across the component to be measured.
- Verenga kukosha kwekudzivisa pachiratidziro.
5.5 Kuyera Kugona
- Unganidza iyo nhema bvunzo inotungamira kune iyo COM jack uye bvunzo dzvuku zvinotungamira kune VΩHz-+ jack.
- Ensure the capacitor is fully discharged before measurement to avoid damage to the multimeter.
- Touch the test probes across the capacitor terminals.
- Verenga iyo capacitance kukosha pane inoratidzwa.
5.6 Kuyera Tembiricha
- Connect the temperature sensor (thermocouple) to the VΩHz-+ uye COM jacks, observing polarity if applicable.
- Place the tip of the temperature sensor on or near the object whose temperature is to be measured.
- Read the temperature value on the display. The unit can be switched between Celsius and Fahrenheit.
5.7 Vasina-Kubata Voltage (NCV) Kuonekwa
Basa reNCV rinobvumira kuona AC voltage without direct contact with conductors.
- Press the NCV button to activate the NCV mode.
- Move the top of the multimeter near the conductor or outlet.
- The display will show an increasing number of bars and an audible beep will indicate the presence and strength of AC voltage.

Image 5.1: The multimeter performing a Non-Contact Voltage (NCV) test near a power strip, indicated by the signal icon on the display.
5.8 Diode Test and Continuity
These functions are typically accessed through the VΩHz-+ jack and a dedicated button or range selection.
- Diode Bvunzo: Connect the red lead to the anode and the black lead to the cathode of the diode. The display will show the forward voltagkudonha. Dzosa mawaya kuti utarise kana circuit yakavhurika.
- Continuity Test: Touch the probes to the two points of the circuit. A continuous beep indicates a low resistance path (continuity).
6. Kuchengeta
6.1 Kuchenesa
Pukuta nyaya yacho neadamp jira nesipo isina kunyorova. Usashandise zvinogumbura kana zvinonyungudutsa. Chengeta nzvimbo dzekupinda dzisina tsvina kana hunyoro.
6.2 Kutsiviwa kwebhatiri
Refer to Section 4.1 for battery replacement instructions. Replace batteries promptly when the low battery indicator appears on the display.
6.3 Fuse Kutsiva
The multimeter is protected by internal fuses. If the current measurement function stops working, the fuse may need replacement. Fuse replacement should only be performed by qualified personnel. Refer to the specifications for fuse ratings.
7. Kugadzirisa matambudziko
- Hapana kuratidzwa kana kuratidzwa kudiki: Tarisa kuiswa kwebhatiri uye kuchaja. Tsiva mabhatiri kana zvichidikanwa.
- Kuverenga kusina kururama: Ensure test leads are properly connected, the correct function/range is selected, and the batteries are not low.
- Kuyera kwazvino hakusi kushanda: Check the fuse. If blown, replace with a fuse of the correct rating.
- "OL" or "OVER" on display: Indicates an overload or out-of-range measurement. Select a higher range or ensure the input is within the device's limits.
8. Zvinotsanangurwa
| Parameter | Range/Kukosha |
|---|---|
| Display Type | Digital Display, 9999 Counts, EBTN Black Display, Analog Bar Graph |
| Capacitance | 9.99nF / 99.99nF / 999.9nF / 9.99µF / 99.99µF / 999.9µF / 9.999mF |
| Voltage (AC/DC) | 99.99mV / 999.9mV / 9.999V / 99.99V / 999.9V |
| Current (AC/DC) | 99.99µA / 999.9µA / 99.99mA / 999.9mA / 9.999A |
| Resistance | 99.99Ω / 999.9Ω / 9.999kΩ / 99.99kΩ / 999.9kΩ / 9.999MΩ / 99.99MΩ |
| Frequency | 99.99Hz / 999.9Hz / 9.999kHz / 99.99kHz / 999.9kHz / 5MHz |
| Tembiricha | -20°C ~ 1000°C / -4°F ~ 1832°F |
| Diode Bvunzo | Ehe |
| Continuity | Ehe |
| Duty Cycle | 1% - 99% |
| Sampling Rate | Ka3 pasekondi |
| Simba | 2 x 1.5V AA mabhatiri |
| Operating Mode | Auto/Manual Range |
| Operating Temperature | 0-40°C |
| Kushanda Humidity | ≤ 75% RH |
| Storage Condition | -20 ~ 60°C |
| Kuchengetedza Humidity | ≤ 80% RH |
| Safety Rating | 600V CAT III, 1000V CAT II (inferred) |
9. Warranty uye Tsigiro
Specific warranty information is not provided in the product details. For warranty claims or technical support, please contact the retailer or manufacturer directly. Keep your purchase receipt as proof of purchase.