1. Nhanganyaya
Thank you for choosing the PerfectPrime TC0521 4-Channel Thermocouple Thermometer. This instrument is designed for precise temperature measurement across multiple points simultaneously, supporting K, J, E, T, N, R, and S type thermocouples. It features data logging capabilities, USB PC connectivity, and wireless mobile app integration for convenient monitoring and analysis. This manual provides essential information for the safe and efficient operation of your device.
2. Chigadzirwa Pamusoroview
Key Features
- Four Channels Thermocouple Thermometer supporting K, J, E, T, N, R, S Type.
- 3.35" LCD display for clear readings.
- Internal DataLog Storage: 32,000 data logger records per channel.
- USB PC Interface: Real-time monitoring, graphic display, data logging, storage, and data import/export.
- Wireless connectivity to mobile apps (iOS and Android).
- Fast response and sampling rate.
- Adjustable auto power-off timer.
- Temperature alarm function.
- Instant recall function for stored data.
Component Identification



3. Setup
3.1 Kuiswa kwebhatiri
- Tsvaga mukamuri yebhatiri kuseri kwemudziyo.
- Vhura chivharo chebhatiri.
- Insert 4 AAA 1.5V batteries, ensuring correct polarity.
- Vhara chivharo chebhatiri zvakachengeteka.
3.2 Connecting Thermocouple Probes
- Identify the four input ports (T1, T2, T3, T4) at the top of the thermometer.
- Connect the K-type bead probes (or other compatible thermocouple types) to the desired input ports. Ensure the positive (+) and negative (-) terminals of the probe connector align with the corresponding markings on the thermometer.
- For accurate readings, ensure the probes are securely inserted.

3.3 Kuisa Software neMobile App
- PC Software: Download the Windows software (compatible with XP/Vista/7/8/10) from the manufacturer's website. Tevedza mirairo yepa-screen yekuisa.
- Mobile App: Tsvaga the PerfectPrime mobile app on the iOS App Store or Android Play Store. Install the app and follow the in-app instructions to connect wirelessly via Bluetooth.
4. Operating Instructions
4.1 Simba On/Kudzima
- Press the Simba bhatani rekushandura iyo thermometer.
- Dzvanya uye ubate iyo Simba button again to turn the thermometer off.
- The device features an adjustable auto power-off timer to conserve battery life.
4.2 Basic Temperature Measurement
- Ensure probes are correctly connected to the input ports.
- Power on the device. The display will show temperature readings for each active channel.
- Place the probe tips at the desired measurement points. Allow a few moments for the readings to stabilize.
4.3 Sarudzo yeZvikamu (°C/°F)
- Press the UNIT bhatani rekuchinja pakati pemayuniti ekupisa eCelsius (°C) neFahrenheit (°F).
4.4 Data Bata Basa
- Press the BATA button to freeze the current temperature readings on the display.
- Press the BATA button again to release the hold and resume live readings.
4.5 Min/Max/Avg Functions
- Press the MAX button to display the maximum temperature recorded since the device was powered on or the function was reset.
- Press the MIN button to display the minimum temperature recorded.
- Press the AVG button to display the average temperature recorded.
- To reset these values, typically a long press of the respective button or a specific sequence might be required (refer to the included mini-manual for exact steps).
4.6 Kumashure
- Press the Backlight button (often represented by a light bulb icon) to turn the display backlight on or off for improved visibility in low-light conditions.
4.7 Data Logging and Wireless Connectivity
- The device can store up to 32,000 data records per channel internally.
- Connect the thermometer to a PC via the micro USB cable or wirelessly to your mobile device via Bluetooth.
- Use the dedicated PC software or mobile app to configure data logging intervals, view real-time data, analyze trends, and export recorded data.
5. Kuchengeta
- Kuchenesa: Pukuta chigadziro nemucheka wakapfava, wakaoma. Usashandise abrasive cleaners kana solvents.
- Kutsiva Bhatiri: Tsiva mabhatiri kana chiratidzo chebhatiri diki chaonekwa pachiratidziro kuti uve nechokwadi chekuti unoshanda nguva dzose.
- Kuchengeta: Store the thermometer in a cool, dry place away from direct sunlight and extreme temperatures when not in use. Remove batteries if storing for extended periods.
- Probe Care: Handle thermocouple probes carefully. Avoid bending or kinking the wires excessively. Replace damaged probes to maintain accuracy.
6. Kugadzirisa matambudziko
- Hapana Simba: Tarisa kuiswa kwebhatiri uye ona kuti mabhatiri matsva.
- Kuverenga Kusina Kurongeka: Verify probe connections, ensure the correct thermocouple type is selected (if applicable), and check for damaged probes. Allow sufficient time for readings to stabilize.
- Matambudziko Ekubatanidza: For PC connection, ensure the USB cable is properly connected and drivers are installed. For mobile app, ensure Bluetooth is enabled on both devices and the app is correctly paired.
- Ratidza Zvikanganiso: If the display shows '----' or other error messages, check probe connections and ensure the measured temperature is within the device's specified range.
7. Zvinotsanangurwa
| Feature | Tsanangudzo |
|---|---|
| Measurement Temperature Range (K-type) | -200°C kusvika 1372°C (-328°F kusvika 2501°F) |
| Measurement Temperature Range (J-type) | -200°C kusvika 1000°C (-328°F kusvika 1832°F) |
| Measurement Temperature Range (E-type) | -200°C kusvika 750°C (-328°F kusvika 1382°F) |
| Measurement Temperature Range (T-type) | -200°C kusvika 400°C (-328°F kusvika 752°F) |
| Accuracy (J, K, E, T, N-type) | ±(0.1% of reading + 0.7°C) above -100°C; ±(0.5% of reading + 0.7°C) below -100°C |
| Accuracy (R, S-type) | ±(0.2% yekuverenga + 1.4°C) |
| Temperature Resolution (K, J, E, T, N-type) | 0.1°C (<600°C), 1°C (≥600°C) |
| Temperature Resolution (R, S-type) | 0.2°C (<600°C), 1°C (≥600°C) |
| Sample Rate | Ka2 pasekondi |
| Bhatiri Type | 4 x AAA 1.5V mabhatiri |
| Battery Lifetime (Bluetooth OFF) | Approx. 120 maawa (alkaline bhatiri) |
| Battery Lifetime (Bluetooth ON) | Approx. 30 maawa (alkaline bhatiri) |
| Operation Temperature | 0°C kusvika 50°C (32°F kusvika 122°F) |
| Operation Humidity | 10 kusvika 90% RH (isina-condensing) |
| Storage Temperature | -20°C kusvika 60°C (-4°F kusvika 140°F) |
| Kuchengetedza Humidity | 10 kusvika 75% RH |
| Dimensions | 187mm (L) × 75mm (W) × 29mm (H) |
| Kurema | Approx. 290g |
| Display Type | LCD |
| Kubatana Technology | USB, Bluetooth |
| Outer Material | Polycarbonate (PC) |
8. Chii chiri muBhokisi
- PerfectPrime TC0521 Thermocouple Thermometer
- Chinyorwa Chirairo (gwaro iri)
- AAA 1.5V batteries (4 pcs)
- Micro USB tambo
- K-type bead probes (2 pcs)
- Windows software (available for download)
9. Warranty uye Tsigiro
While specific standard warranty details are not provided in the product information, PerfectPrime is committed to product quality. An optional 1-Year Extended Warranty Plan by Onsitego is available for purchase. For technical support, troubleshooting assistance, or warranty inquiries, please refer to the contact information provided with your purchase or visit the official PerfectPrime website.
This device has a Certificate of Calibration from the National Measurement Laboratory R.O.C (NML/ROC) and is Made in Taiwan, ensuring quality and reliability.


