ANKO ANKPS-301

ANKO GFCI Outlet 20 Amp Bhuku reMirayiridzo

Model: ANKPS-301 | Brand: ANKO

1. Nhanganyaya

The ANKO 20 Amp GFCI (Ground Fault Circuit Interrupter) Outlet is designed to provide enhanced electrical safety by quickly detecting and interrupting ground faults. This device is UL Listed, tamper-resistant, and weather-resistant, making it suitable for both indoor and outdoor applications. This manual provides essential information for the safe and correct installation, operation, and maintenance of your GFCI outlet.

2. Chii chiri muBhokisi

  • GFCI Outlet 20 Amp
  • Decor Wall Plate
  • Mounting Screws
  • Mirairo yekuisa (iri bhuku)

3. Key Features

  • UL Yakanyorwa: Certified for safety and performance.
  • TampInodzivirira (TR): Prevents insertion of foreign objects into the receptacle openings, enhancing child safety.
  • Inodzivirira Mamiriro Ekunze (WR): Constructed with advanced UV stabilized engineering for superior corrosion, temperature, and UV resistance, ideal for outdoor and indoor use.
  • Self-Test Basa: Automatically conducts an internal test every 40 seconds to confirm proper ground fault protection.
  • Chiratidzo che LED: Provides visual feedback on power and protection status (Green for working, Red for End-of-Life).
  • Thermoplastic Inodzivirira Kukuvadzwa Kwakanyanya: Inovimbisa kugara kwenguva refu uye kusimba.
  • Back and Side Wire Options: Offers flexible wiring connections.
ANKO GFCI Outlet with features highlighted: UL Listed, Tamper Resistant, Weather Resistant, 20A/125V/2500W with LED Indicator, Standard Wall Plate & Screws Included, Performs a Self-Test Every 40 Seconds, Back and Side Wire.

Image: Key features of the ANKO GFCI Outlet, including UL listing, tamper and weather resistance, and self-test capability.

4. Safety Information

WARNING: Risk of Electric Shock or Electrocution. Installation requires electrical knowledge. If you are unsure about any part of these instructions, consult a qualified electrician.

  • Nguva dzose dzima magetsi pa circuit breaker kana pa fuse box usati waisa kana kugadzirisa soketi.
  • Use only copper wire. Do not use with aluminum wire.
  • Iva nechokwadi chekuti waya dzese dzakabatana dzakachengeteka uye dzakadzivirirwa zvakanaka.
  • Do not install in wet locations unless protected by a weatherproof enclosure.
  • A GFCI outlet is designed to protect against ground faults, not against electrical overload or short circuits.
Diagram explaining 'What is a GFCI?' showing how it detects ground faults and trips to prevent injury. It also details the self-test and LED indicator functions.

Image: Explanation of GFCI functionality, highlighting its role in preventing serious injury by interrupting ground faults and detailing the LED indicator's meaning.

5. Kuisa Nongedzo

5.1. Zvishandiso Zvinodiwa

  • Screwdriver (Phillips uye Flathead)
  • Wire Strippers
  • Electrical Tape (optional)
  • Voltage Tester

5.2. Wiring Instructions

  1. Dzima Simba: Tsvaga circuit breaker kana fuse inodzora soketi yauri kutsiva kana kuisa. Idzime. Iva nechokwadi chekuti simba radzimwa uchishandisa voltage muedzo.
  2. Ziva Waya: Carefully pull the existing outlet from the wall box (if replacing). Identify the LINE wires (incoming power from the breaker) and LOAD wires (outgoing power to other outlets downstream). The GFCI outlet has clearly marked LINE and LOAD terminals.
  3. Strip Wires: Strip approximately 1/2 inch of insulation from the ends of the wires.
  4. Batanidza Waya:
    • Connect the bare copper or green insulated GROUND wire to the GREEN grounding screw terminal.
    • Connect the incoming LINE (hot/black) wire to the BRASS LINE terminal.
    • Connect the incoming LINE (neutral/white) wire to the SILVER LINE terminal.
    • If you have downstream outlets to protect, connect the outgoing LOAD (hot/black) wire to the BRASS LOAD terminal.
    • If you have downstream outlets to protect, connect the outgoing LOAD (neutral/white) wire to the SILVER LOAD terminal.

    Note: If there are no downstream outlets to protect, cap off the LOAD terminals with electrical tape or wire nuts.

  5. Secure Connections: Ensure all wires are securely fastened to their respective terminals. The ANKO GFCI supports both back-wire (inserting stripped wire into hole and tightening screw) and side-wire (wrapping wire around screw) connections.
  6. Mount Outlet: Carefully fold the wires into the electrical box and secure the GFCI outlet to the box with the provided screws. Attach the wall plate.
Diagram showing the different terminals on the back of the GFCI outlet: Grounding Terminal (Green Screw), Line White Terminal (Silver Screw), Line Hot Terminal (Brass Screw), Load White Terminal (Silver Screw), Load Hot Terminal (Brass Screw).

Mufananidzo: Zvakadzama view of the GFCI outlet's terminals, indicating connections for Grounding, Line (incoming power), and Load (outgoing power to protected circuits).

Wiring diagrams for GFCI outlet installation. One diagram shows a single cable (2-3 wires) entering the box, connecting to LINE. The second diagram shows two cables (4-6 wires) entering the box, connecting to LINE and LOAD, with a downstream outlet.

Image: Visual guide for wiring the GFCI outlet, illustrating connections for both single-cable and multiple-cable setups, including protection for downstream outlets.

5.3. Bvunzo Yekutanga

  1. Dzosera Simba: Dzorera magetsi pa circuit breaker kana pa fuse box.
  2. Dzvanya RESET: The GFCI outlet should now have power. Press the RESET button. The LED indicator should turn GREEN.
  3. Dzvanya KUYEDZA: Press the TEST button. The GFCI should trip, and the LED indicator should turn OFF or RED.
  4. Dzvanya RESET Zvakare: Press the RESET button again. The GFCI should reset, and the LED indicator should turn GREEN.

If the GFCI does not reset or the LED does not turn green, check your wiring connections and ensure the power is on. If issues persist, consult a qualified electrician.

6. Operating Instructions

6.1. TEST and RESET Buttons

  • TEST Button (Black): Used to manually trip the GFCI to verify its protection function. When pressed, the GFCI should trip, cutting off power to the receptacles.
  • RESET Button (Red): Used to restore power to the GFCI after it has tripped (either manually or due to a ground fault).

6.2. Chiratidzo che LED

  • Solid Green: The GFCI is functioning correctly and providing ground fault protection.
  • Off or Red: The GFCI has tripped, or there is no power to the outlet.
  • Flashing Red (End-of-Life): The GFCI has reached the end of its useful life and can no longer provide ground fault protection. It must be replaced immediately.

6.3. Self-Test Function

The ANKO GFCI outlet automatically performs a self-test every 40 seconds. During this test, the red light may blink once. This is normal operation and indicates the GFCI is continually monitoring its ability to protect against ground faults.

7. Kuchengeta

  • Monthly Testing: It is recommended to test your GFCI outlet monthly to ensure proper operation. Follow the "Initial Test" steps outlined in Section 5.3.
  • Kuchenesa: Clean the surface of the outlet and wall plate with a soft, damp jira. Usashandise abrasive cleaners kana solvents.
  • Kuongorora: Periodically inspect the outlet for any signs of damage, such as cracks, discoloration, or loose connections.

8. Kugadzirisa matambudziko

DambudzikoZvinogona KukonzeraSolution
GFCI will not reset (LED is off or red)No power to the outlet
Ground fault yaonekwa
Wiring isina kunaka
Kupera-kweHupenyu
Tarisa wedunhu breaker/fuse
Unplug all devices, press RESET. If it holds, plug devices back one by one to find faulty one.
Verify LINE/LOAD connections are correct.
Replace the GFCI outlet.
GFCI trips frequentlyFaulty appliance/device
Moisture in circuit
Dunhu rakaremerwa
Test devices on another outlet. Discontinue use of faulty device.
Ensure outlet is protected from moisture, especially in outdoor/damp nzvimbo.
Reduce the number of devices on the circuit.
No power to downstream outletsGFCI yakagumburwa
Improper LOAD wiring
GFCI not first in circuit
Press RESET button.
Verify LOAD wires are correctly connected to the GFCI's LOAD terminals.
Ensure the GFCI is the first outlet in the circuit to protect downstream outlets.

9. Zvinotsanangurwa

  • Model Number: ANKPS-301
  • Rating: 20 Amp, 125 Volt, 60 Hz
  • Material: High-Impact Resistant Thermoplastic (Polycarbonate - PC)
  • Ruvara: Chena
  • Zviyero zvechigadzirwa: 4.6 inches (L) x 2.7 inches (W) x 0.04 inches (D) (Faceplate); 4.06 inches (L) x 1.69 inches (W) (Outlet Body)
  • Zvitupa: UL Listed YGB-095WR
  • Features: Tamper-Resistant (TR), Weather-Resistant (WR), LED Indicator, Self-Test
Diagram showing the dimensions of the ANKO GFCI outlet and its wall plate. The wall plate is 4.6 inches long and 2.7 inches wide. The outlet body is 4.06 inches long and 1.69 inches wide.

Image: Dimensional specifications of the ANKO GFCI outlet and its accompanying wall plate.

10. Warranty uye Tsigiro

Specific warranty details for the ANKO GFCI Outlet are not provided in this manual. For warranty information, technical support, or any product-related inquiries, please contact ANKO customer service directly or refer to the product packaging and official ANKO website.

It is recommended to retain your purchase receipt for warranty purposes.

Related Documents - ANKPS-301

Preview Anko Low Voltage 4ft Santa Inflatable: Installation and Safety Guide
Gwaro rakazara reAnko Low Voltage 4ft Santa Inflatable, covering installation, safety warnings, and adaptor manual. Model JT-DC12V9W-F3, Keycode 43069835.
Preview Anko Bluetooth Mvura Inodzivirira Ruvara Inoyangarara Inoyangarara Mutauri Wekushandisa
Gwaro remushandisi weAnko Bluetooth Mvura-Inodzivirira Ruvara Inoyerera Inoyerera Mutauri (Modhi 43206056), inotsanangura zvakatemwa, mirairo yekushandiswa, mabhatani mabasa, uye akakosha ekuchengetedza.
Preview Anko Mvura Inodzivisa Mutauriri Dhadha User Manual
Chinyorwa chemushandisi cheAnko Mvura Inodzivirira Mutauri Duck (Modhi: EBS-24106), inotsanangura maitiro ayo, mashandiro, zvakatemwa, uye ruzivo rwewaranti.
Preview Anko 43308026 Kisimusi Battery Inoshandiswa Chiedza Kumusoro NepaNorth Pole Sign - Mushandisi Wekushandisa
Yakadzama mirairo uye gwara regungano reAnko 43308026 Kisimusi Bhatiri Inoshandiswa Chiedza Kumusoro NekuNorth Pole Sign. Dzidza maitiro ekumisikidza, kushandisa, uye kutarisira kushongedza kwako kwezororo rezororo.
Preview Anko Low Voltaguye Kisimusi Lamp Positi: Kuchengetedzwa, Kuiswa & Gwaro Rekugadzika
Gwaro rakazara reAnko Low Voltaguye Kisimusi Lamp Positi (Modhi: JT-DC4.5V3.6W-E3, Keycode: 43069231). Inosanganisira yambiro dzakakosha dzekuchengetedza, mirairo yekuisa nhanho nhanho, uye ruzivo rwekuungana kwekushandisa mukati nekunze.
Preview Bhuku reMirayiridzo yeAnko Collapsible Bath
Bhuku remirayiridzo yeAnko Collapsible Bath, kusanganisira kuungana, kupatsanurwa, ruzivo rwemushandisi, uye yambiro dzakakosha dzekuchengetedza dzekushandisa nevacheche nevana. Rine chiratidzo chekupisa uye ruzivo rweKmart Australia neNew Zealand.