Weil-McLain AB-155C

Bhuku rekushandisa reWeil-McLain AB-155C AquaBalance Combination Wall Mount Gas Boiler

Model: AB-155C

1. Nhanganyaya

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Weil-McLain AB-155C AquaBalance Combination Wall Mount Gas Boiler. Please read this manual thoroughly before attempting any installation or operation procedures. Retain this manual for future reference.

The AquaBalance combi-boiler is designed to provide high-efficiency space heating and on-demand domestic hot water in a compact, wall-mounted unit. It features a 95% annual fuel utilization efficiency (AFUE) for reduced energy consumption.

2. Safety Information

YAMBIRO: Kuisa, kugadzirisa, kushandura, sevhisi, kana kugadzirisa zvisizvo zvinogona kukonzera kukanganisa, kukuvara, kana kufa. Verenga mirairo yekuisa, kushanda, uye kugadzirisa zvakakwana usati waisa kana kusevhisa mudziyo uyu.

ZVINOKOSHA ZVINOTEVEDZERA MIrairo:

  • Ensure all local codes and regulations are followed during installation.
  • Kuiswa uye sevhisi zvinofanirwa kuitwa nemunhu ane hunyanzvi anoisa, sevhisi agency, kana gasi mutengesi.
  • Usachengete kana kushandisa peturu kana imwe mhute uye zvinwiwa zvinobvira padyo neizvi kana chero chimwe chishandiso.
  • If you smell gas, follow the instructions provided by your gas supplier immediately. Do not operate any electrical switches, light matches, or use any flame-producing device.
  • Keep the area around the boiler clear and free from combustible materials.
  • Mudziyo uyu ndewekuisa mukati memba chete.

3. Chigadzirwa Pamusoroview

3.1 Mamiriro Akakosha

  • Kunyatsogona: 95% AFUE for energy savings.
  • Rudzi rwemafuta: Natural Gas (NG) operation, with optional LP conversion kit available.
  • Compact Design: Wall-mounted for space-saving installation.
  • Quiet Operation: Heavy gauge insulated jacket.
  • Modulation: 10-to-1 turn down ratio for precise energy matching.
  • Utsi Hushoma: Low NOx rated, South Coast certified.
  • Heat Exchanger: Single tube, large diameter, ASME certified 316L Stainless Steel.
  • Zvinodzora: Honeywell boiler control with digital display.
  • Vent Options: Unique 3-in-1 vent adapter (PVC, CPVC, SS, PP), multiple direct vent options.
  • Integrated Components: Internal condensate trap, 24VAC thermostat relay, internal 3-speed circulator, DHW flat plate heat exchanger.

3.2 Boiler Zvikamu

The following image illustrates the exterior of the Weil-McLain AB-155C AquaBalance boiler.

Weil-McLain AB-155C AquaBalance Combination Wall Mount Gas Boiler

Mufananidzo 1: Mberi view of the Weil-McLain AB-155C AquaBalance Combination Wall Mount Gas Boiler. The unit is white with two vent connections on top. A control panel with a digital display and an AquaBalance logo are visible on the lower front panel.

Note: For detailed internal component diagrams, refer to the full installation manual provided with the product.

4. Kuiswa (Setup)

Installation must be performed by a qualified professional in accordance with all national and local codes.

4.1 Pre-Instalation Checks

  • Verify boiler model (AB-155C) and fuel type (Natural Gas).
  • Ensure adequate clearances for service and combustion air.
  • Confirm proper venting system design (direct vent with 2 pipes or concentric, through sidewall or roof).
  • Check electrical supply (120V, pre-wired with 3-prong plug).
  • Confirm water supply and return connections are accessible.

4.2 Kuisa Boiler

  1. Select a suitable wall location capable of supporting the boiler's weight.
  2. Use the provided wall mounting bracket and hardware.
  3. Ensure the boiler is level and securely fastened.

4.3 Venting System Connection

Connect the venting system using the unique 3-in-1 vent adapter, compatible with PVC, CPVC, SS, or PP vent materials. Follow manufacturer guidelines for vent pipe sizing and termination.

4.4 Plumbing and Electrical Connections

  • Connect heating system supply and return lines.
  • Connect domestic cold water inlet and hot water outlet.
  • Connect gas supply line.
  • Plug the commercial grade 120V power cord into a grounded outlet.
  • Connect the 24VAC thermostat relay.

5. Kushanda

5.1 Kutanga Kutanga

  1. Ensure all gas, water, and electrical connections are secure and leak-free.
  2. Purge air from the heating system.
  3. Vhura gasi rekupa gasi.
  4. Batidza simba remagetsi kubhailer.
  5. Follow the instructions on the Honeywell boiler control digital display for initial setup and parameter configuration.

5.2 Kujairika Kushanda

The boiler will operate automatically based on the thermostat demand for space heating and domestic hot water. The digital display provides operational status and diagnostic information.

5.3 Shutdown Procedures

  • Temporary Shutdown: Turn off the thermostat or set it to a low temperature.
  • Kuvhara Kwakawedzerwa: Turn off the electrical power to the boiler and close the main gas supply valve. If freezing temperatures are expected, drain the boiler and heating system to prevent damage.

6. Kuchengeta

Regular maintenance is crucial for the longevity and efficient operation of your boiler. Maintenance should be performed by a qualified service technician.

6.1 Annual Maintenance (Recommended)

  • Inspect and clean the heat exchanger.
  • Check and clean the condensate trap.
  • Inspect the venting system for blockages or leaks.
  • Verify proper operation of all safety controls.
  • Check gas pressure and combustion settings.
  • Inspect all water and gas connections for leaks.
  • Test the pressure relief valve.

6.2 Kuchengetedza Kwemushandisi

  • Keep the area around the boiler clear of obstructions.
  • Visually inspect the boiler and venting system periodically for any signs of damage or leaks.
  • Ensure the condensate drain line is not blocked.

7. Kugadzirisa matambudziko

This section provides basic troubleshooting steps for common issues. For complex problems, contact a qualified service technician.

DambudzikoZvinogona KukonzeraSolution
No Heat / No Hot WaterThermostat set too low; Power supply off; Gas supply off; Boiler lockout.Check thermostat setting; Verify power to boiler; Ensure gas valve is open; Consult digital display for error codes and reset if possible.
Boiler Leaking WaterLoose connection; Pressure relief valve discharge; Internal component failure.Tighten connections; Check system pressure (should be within operating range); Contact service technician for internal leaks.
Ruzha rusina kujairikaAir in system; Pump issue; Combustion issue.Bleed air from system; Contact service technician.

Refer to the boiler's digital display for specific error codes and their meanings.

8. Zvinotsanangurwa

  • Muenzaniso: AB-155C
  • Brand: Weil-McLain
  • Rudzi rwemafuta: Gasi Rakasikwa (NG)
  • BTU Input: 155,000 BTU
  • BTU Kubuda: 125,000 BTU
  • DOE Rating: 144,000
  • IBR Rating: 125,000
  • Kushanda Nesimba (AFUE): 95%
  • System Type: Hydronic (Water)
  • Vent Type: Direct Vent
  • Voltage: 120 Volts
  • Mounting Type: Wall
  • Urefu: 27.56 inches
  • Features: Condensing, Combo Domestic Water, EI/Spark Ignition, Wall Mounted, Energy Star Rated.
  • UPC: 384929219720
  • Chikamu Nhamba: 383-100-050

9. Warranty uye Tsigiro

9.1 Ruzivo rweWaranti

  • Heat Exchanger: 10 Year Limited Warranty for Residential Use / 5 Years Limited for Commercial Use.
  • Zvikamu: 2 Makore Yakaganhurirwa Warranty.

Please refer to the official Weil-McLain warranty document included with your product for complete terms and conditions.

9.2 Mutengi Tsigiro

For technical assistance, service, or warranty claims, please contact your authorized Weil-McLain dealer or visit the official Weil-McLain website.

Weil-McLain Official Websaiti: www.weil-mclain.com

Related Documents - AB-155C

Preview Weil-McLain LGB Commercial Gasi Boiler Series 2: Zvinotsanangurwa, Dimensions, uye Ratings
Hurukuro hwehunyanzvi hwakazara, zviyero, madhayagiramu epombi, uye kuyerwa kwekuita kweWeil-McLain LGB Commercial Gas Boiler Series 2. Yakanakira kutengeserana, masangano, uye akawanda-emhuri ekudziya maapplication.
Preview Weil-McLain Simplicity Parts Kit for Boilers
Comprehensive parts kit for Weil-McLain Simplicity boilers, including essential components for emergency repairs to minimize downtime and optimize efficiency. Details contents for boiler sizes 110/150 and 199.
Preview Weil-McLain EVERGREEN Pro 110/155 Condensing Gasi Boiler Yepamusoro Manual
Yakazara yepamusoro bhuku reWeil-McLain EVERGREEN Pro 110/155 inodzoreredza gasi boilers, yekuvharira kuisirwa, kuseta yepamusoro, akawanda boiler masisitimu, wiring, uye kudzora kushanda.
Preview Weil-McLain CP Date Ranges uye Boiler Identification Guide
Tsvaga mazuva anofungidzirwa ekugadzira eWeil-McLain boilers uchishandisa iyo nhamba yeCP neiyi tafura yekutarisa yemazuva. Inosanganisira ruzivo rwemuenzaniso uye ruzivo rwekufonera.
Preview Weil-McLain CP Sticker Locations by Boiler Model
A guide to finding the CP (serial) number on various Weil-McLain boiler models, including AquaBalance, CGa/CGi, ECO, ECO Tec, Evergreen, GV90+, and Ultra.
Preview Weil-McLain SVF 500/600 Series Boiler Manual
Comprehensive installation, operation, and maintenance manual for Weil-McLain SVF 500 and SVF 600 Commercial Condensing Gas-Fired Water Boilers. Covers safety, installation procedures, electrical wiring, controls, troubleshooting, and service information.