1. Nhanganyaya
Thank you for choosing the ERICKHILL RT-100 EMF Meter. This device is designed to detect and measure electromagnetic field (EMF) radiation, helping you identify potential sources of electromagnetic pollution in your environment. This manual provides essential information for the safe and effective use of your meter.

Figure 1: ERICKHILL RT-100 EMF Meter
2. Chigadzirwa Pamusoroview
2.1 Zvikamu
- Front Sensing Area: The area where electromagnetic radiation is detected.
- LCD Digital Display: Shows measurement values, units, and status indicators.
- BATA Bhatani: Inomisa kuverenga ikozvino pachiratidziro.
- AVG/VPP Button: Switches between average and peak value readings.
- UNIT Bhatani: Changes the measurement unit (mG/uT for magnetic field, V/m for electric field).
- Bhatani reSimba: Turns the device on/off and controls the buzzer.
- Type-C yekuchaja Port: For recharging the internal Lithium Polymer battery.
2.2 Zviratidzi

Figure 2: Display Indicators and Features
- AVG: Average reading mode.
- VPP: Peak value reading mode.
- E-field: Electric field measurement (V/m).
- H-munda: Magnetic field measurement (mG or µT).
- Yambiro Indicator: Screen turns red and indicator flashes when thresholds are exceeded.
- Chiratidzo chebhatiri: Inoratidza hupenyu hwebhatiri hwasara.
- Sound Alarm Icon: Zvinoratidza kana buzzer iri kushanda.
- 'H' Icon: Indicates data hold is active.
3. Setup
3.1 Kuchaja Chishandiso
The ERICKHILL RT-100 EMF Meter comes with a built-in rechargeable Lithium Polymer battery. Use the provided Type-C charging cable to charge the device. Connect the Type-C end to the meter's charging port and the USB-A end to a compatible USB power adapter (not included).

Mufananidzo 3: Kuchaja kweType-C
3.2 Simba On/Kudzima
To power on the device, press and hold the Power button until the display illuminates. To power off, press and hold the Power button again.
4. Operating Instructions
4.1 Yekutanga kuyerwa
Once powered on, the meter will immediately begin measuring electric (E-field) and magnetic (H-field) radiation. The values will be displayed on the LCD screen. For accurate readings, slowly approach the electromagnetic radiation source with the front sensing area of the meter. The effective and optimal measurement range is 0-30 cm.
4.2 Kuchinja kweyuniti
Press the UNIT button to switch between different measurement units:
- For Magnetic Field: mG (milligauss) or µT (microtesla).
- For Electric Field: V/m (volts per meter).
4.3 Average/Peak Value Reading
Press the AVG/VPP button to toggle between average (AVG) and peak value (VPP) readings. The AVG mode displays the average radiation level, while VPP mode shows the maximum (peak) value detected during the measurement period.
4.4 Data Bata
Kuti uomese kuverenga kwemagetsi kuri pachiratidziro, tinya bhatani rekuti BATA button. An 'H' icon will appear on the screen. Press the BATA button again to exit data hold mode and resume real-time measurements. Ensure data hold is off when taking new measurements.
4.5 Sound-Light Alarm
The meter features a sound and light alarm. When the detected radiation level exceeds the preset safety thresholds (0.4 µT (4mG) for magnetic field or 40 V/m for electric field), the screen will turn red, the warning indicator will flash, and a buzzer will sound. To silence the buzzer, press and hold the Power button briefly. The visual alarm (red screen, flashing indicator) will remain active.
4.6 Kumashure
The large LCD display is backlit for clear viewkupenya mumamiriro akasiyana-siyana emwenje.
4.7 Auto Power Off
Mudziyo unozodzima wotodzima mushure memaminitsi masere ekusaita kuti uchengetedze hupenyu hwebhatiri.
5. Zvikumbiro
The ERICKHILL RT-100 EMF Meter can be used to test electromagnetic radiation from a variety of sources:
- Midziyo yepamba: TVs, computers, printers, microwave ovens, refrigerators, air conditioners.
- Electronic Devices: Cell phones, laptops, power strips.
- Infrastructure: Cell towers, low-frequency home appliances.
- Zvimwe: Ghost hunting equipment.




5.1 Demonstration Videos
6. Kuchengeta
- Chengetedza mudziyo wakachena uye wakaoma. Shandisa nyoro, damp jira rekupukuta kunze. Usashandise abrasive cleaners kana solvents.
- Regedza kuisa mita kune tembiricha yakanyanyisa, mwando, kana zuva rakananga.
- Chengetedza mudziyo panzvimbo yakachengetedzeka kana usingashandisi kudzivirira kukuvadzwa.
- Regularly charge the battery to maintain its performance.
7. Kugadzirisa matambudziko
7.1 Kuverenga Kusina Kururama
- Ensure the front sensing area is slowly approaching the source within the 0-30 cm optimal range.
- Tarisa kana iyo BATA function is active ('H' icon displayed). If so, deactivate it to get real-time readings.
- Verify that the correct units (mG/µT or V/m) are selected for the field you are measuring.
7.2 No Display/Device Not Turning On
- Ensure the battery is charged. Connect the device to a power source using the Type-C cable.
- Dzvanya wobata bhatani rePower kwemasekondi mashoma kuti uve nechokwadi chekuti harisi rekungodzvanya kwenguva pfupi chete.
7.3 Alarm Sounds Continuously
- Move away from the detected radiation source until the readings drop below the alarm thresholds.
- To temporarily silence the buzzer, briefly press and hold the Power button.
8. Zvinotsanangurwa
| Feature | Tsanangudzo |
|---|---|
| Model Number | RT-100 |
| Measurement Range (Magnetic Field) | 0.01-99.99 µT / 0.1-999.9 mG |
| Measurement Range (Electric Field) | 1-1999 V/m |
| Alarm Threshold (Magnetic Field) | 0.4 µT (4 mG) |
| Alarm Threshold (Electric Field) | 40 V/m |
| Simba Source | 1 Lithium Polymer battery (included), rechargeable via Type-C |
| Auto Power Off | Mushure memaminitsi makumi matanhatu ekusaita basa |
| Product Dimensions | 10 x 7 x 4 cm |
| Product Weight | 260 g |
9. Warranty uye Tsigiro
ERICKHILL is committed to providing professional and high-quality meters. We offer lifetime technical support for the RT-100 EMF Meter. If you have any questions or require assistance, please do not hesitate to contact our professional after-sales team. They will solve your problem in a timely manner.