This manual provides detailed instructions for the installation, operation, and maintenance of your Fortis Scala 842080C Wall Mounted Widespread Bathroom Faucet. Please read this manual thoroughly before installation and retain it for future reference. Proper installation and care will ensure optimal performance and longevity of your faucet.
Safety Information
- Nguva dzose dzimai mvura huru musati matanga basa rekuisa kana kugadzirisa.
- Pfekai zvinhu zvekudzivirira zvakakodzera, zvakaita semagirazi ekuchengetedza nemagurovhosi, panguva yekuisa.
- Kana usina chokwadi nezvechikamu chipi zvacho chekuisa, bvunza nyanzvi yepombi.
- Ita shuwa kuti zvese zvinongedzo zvakachengeteka kudzivirira kuvuza.
- This product is designed for use with potable water only.
Package Zviri mukati
Tarisa kuti zvese zviriko zviripo usati watanga kuisa:
- Musangano weSpout yeFaucet
- Handle Assembly (Single Lever)
- Mounting Hardware
- Chinyorwa Chirairo (gwaro iri)

Image: Fortis Scala 842080C Wall Mounted Widespread Bathroom Faucet, showing the spout and single lever handle in a brushed black finish. This image illustrates the main components included in the package.
Zvinotsanangurwa
| Brand | Fortis |
| Model Number | 842080C |
| Mounting Type | Wall Mount, Widespread (2-hole configuration, 8" centers) |
| Finish Type | Brushed Black |
| Nhamba yeMaholo | 1 (Chirevo chimwe chete) |
| Material | Brass yakasimba |
| Flow Rate | 1.2 marita paminiti (GPM) |
| Valve Type | Ceramic Disc Valve |
| Kuteerera | ADA Compliant, Lead-Free Certified |
| Item Weight | 8.7 Pondo |
| Product Dimensions | Approximately 1 x 1 x 1 inches (Note: Refer to product diagrams for precise measurements) |
Setup uye Installation
Kuiswa kwehunyanzvi kunokurudzirwa.
Zvishandiso uye Zvishandiso Zvinodiwa (Zvisina Kubatanidzwa):
- Adjustable Wrench
- Phillips Musoro Screwdriver
- Putty yePlumber kana Silicone Sealant
- Tepi Yechisimbiso Cheshinda (Teflon Tepi)
- Magirazi Okuchengetedza
- Magirovhosi
Pre-Instalation Matanho:
- Dzima Mvura: Locate the main water shut-off valve and turn off the water supply to the bathroom. Open nearby faucets to drain any remaining water from the lines.
- Clear Work Area: Ensure the installation area is clean and free of obstructions.
- Ongorora Zvikamu: Unpack all parts and inspect them for any damage. Contact customer support if any parts are missing or damaged.
Kuisa Matanho:
- Prepare Wall Openings: Ensure the wall openings for the spout and handle are correctly spaced at 8 inches center-to-center.
- Install Valve Body (Rough-in): Follow the rough-in instructions provided with the valve body (if separate) to install it within the wall. Ensure it is level and securely fastened.
- Batanidza Mitsetse Yemvura: Connect the hot and cold water supply lines to the appropriate inlets on the valve body. Use thread seal tape on all threaded connections and tighten securely with a wrench.
- Install Spout Assembly: Insert the spout assembly into its designated wall opening. Apply a bead of silicone sealant around the base of the escutcheon plate before securing it to the wall. Connect the spout to the valve body outlet.
- Install Handle Assembly: Insert the handle assembly into its designated wall opening. Secure the escutcheon plate to the wall, applying sealant as needed. Attach the handle lever to the valve stem according to the specific design.
- Test for Leaks: Slowly turn on the main water supply. Check all connections for leaks. If leaks are detected, turn off the water, tighten the connections, and re-test.
- Flush Faucet: Once installation is complete and no leaks are present, remove the aerator from the spout. Turn on the faucet to full hot and full cold for one minute each to flush out any debris from the water lines. Turn off the faucet, re-install the aerator.
Operation
The Fortis Scala 842080C faucet features a single lever handle for controlling both water flow and temperature.
- Kubatidza/Kudzima: Simudza mubato kuti uvhure mvura. Sundidzira mubato pasi kuti uvhure mvura.
- Kugadzirisa Kuyerera Kwemvura: Kana uchisimudza mubato zvakanyanya, mvura inoyerera zvakanyanya.
- Kugadzirisa Tembiricha Yemvura: Move the handle to the left for hot water and to the right for cold water. The center position provides a mix of hot and cold water.
Maintenance
Kuchenesa:
- Clean the faucet regularly with a soft cloth and mild soap and water.
- Avoid using abrasive cleaners, harsh chemicals, or scouring pads, as these can damage the finish.
- Shamba zvakanaka mushure mekuchenesa wozoomesa nejira rakapfava kudzivirira mavanga emvura.
Aerator Maintenance:
- Kana mvura ikaderera kana kuti ikava isina kurongeka, mudziyo wekufema unogona kunge wakavharwa.
- Unscrew the aerator from the end of the spout.
- Rinse the aerator under running water to remove any debris. Use a soft brush if necessary.
- Re-install the aerator, ensuring it is securely tightened.
Kugadzirisa matambudziko
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Kuyerera Kwemvura Yakaderera | Muchina wekufema wakavharika; vharuvhu yakavharika zvishoma; marara ari mumigero yemvura. | Clean aerator. Ensure shut-off valves are fully open. Flush water lines. |
| Kubuda kwemvura kubva kuFaucet Base | Loose mounting nuts; improper sealant application. | Simbisa nzungu dzinosungirirwa. Isazve putty yeplumber kana silicone sealant kana zvichidikanwa. |
| Leaks from Handle | Worn O-rings or cartridge. | Bata rutsigiro rwevatengi kuti uwane zvimwe zvikamu kana rubatsiro rwenyanzvi. |
| Nyaya dzeTembiricha Yemvura | Improper hot/cold water line connection; water heater issues. | Verify hot and cold lines are connected correctly. Check water heater settings. |
Warranty uye Support
The Fortis Scala 842080C Faucet is covered under Fortis's limited warranty. For specific warranty details, please refer to the warranty card included with your purchase or visit the official Fortis website.
For technical assistance, replacement parts, or warranty claims, please contact Fortis Customer Support:
- Websaiti: www.fortisfaucet.com
- Runhare: [Insert Fortis Customer Service Phone Number Here]
- Email: [Insert Fortis Customer Service Email Here]
When contacting support, please have your model number (842080C) and date of purchase available.