1. Nhanganyaya
This manual provides detailed instructions for the safe and effective use of your KAIWEETS HT206B Clamp Meter and KAIWEETS KM100 Digital Multimeter. Please read this manual thoroughly before operation and retain it for future reference.
2. Safety Information
WARNING: Always observe safety precautions when working with electrical circuits to prevent personal injury or damage to the meter.
- The HT206B meets safety standard IEC 61010-1, CAT III 600V. The KM100 has passed CE and RoHS certifications and is IEC rated CAT III 600V.
- Both devices feature anti-burn protection with double fuses and overload protection on all ranges (KM100).
- Ensure the rotary switch is set to the correct test range before making measurements.
- Usaedza kuyera voltages kana macurrents anopfuura miganhu yakataurwa.
- Ongorora bvunzo inotungamira kune kukuvara usati washandisa yega yega. Usashandise kana insulation yakakanganiswa.
- Pakuyera ikozvino ne clamp meter, only clamp the live wire, not the entire power cord.
3. Chigadzirwa Pamusoroview
3.1 KAIWEETS HT206B Clamp Meter

Figure 1: KAIWEETS HT206B Clamp Chiyero chemita nezvimwe zvinosanganisirwa.
The KAIWEETS HT206B is a True-RMS clamp meter designed for accurate measurements on non-linear loads. It is suitable for various applications in labs, factories, and households.
Zvinokosha:
- Kuyera Kugona: AC Current, AC/DC Voltage, Frequency, Duty Cycle, Resistance, Capacitance, Diode, Continuity, and Temperature.
- Two-color Backlit LCD Display: The screen turns red to warn of high voltage (>80V) or high current (>3A).
- Chiedza che LED: For illumination in dimly lit areas.
- Isiri-Yekubatanidza Voltage (NCV) Kuonekwa: For detecting live wires without direct contact.
- Automatic shutdown: Powers off after 15 minutes of inactivity to conserve battery.
- Low Battery Chiratidzo: Zviziviso kana mabhatiri achida kuchinjwa.

Figure 2: HT206B Clamp Meter feature highlights.

Figure 3: NCV and Hold functions on the HT206B.
3.2 KAIWEETS KM100 Digital Multimeter

Figure 4: KAIWEETS KM100 Digital Multimeter and included accessories.
The KAIWEETS KM100 is a multi-function digital multimeter designed for safety and accuracy in various electrical tests, including household, automotive, and industrial applications.
Zvinokosha:
- Kuyera Kugona: AC / DC Voltage, DC Current, Resistance, Continuity, and Diode Measurement. Note: This model cannot test AC current.
- Backlight Basa: Improves visibility in dark conditions.
- Bata Basa: Locks the displayed measurement value for easy recording.
- Support Stand: Flexible and stable, adjustable up to 90°.
- Safety: CAT III 600V, CE and RoHS certified, with anti-burn double fuses and overload protection.
4. Setup
4.1 Kuiswa kwebhatiri
Both the HT206B and KM100 require AAA batteries for operation.
- Tsvaga chivharo chebhatiri kuseri kwemudziyo.
- Use a screwdriver (if necessary) to open the cover.
- Insert 2 AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment. (For KM100, batteries are typically pre-installed).
- Tsiva chivharo chebhatiri uye chengetedza.
4.2 Connecting Test Leads and Thermocouple
For most measurements, test leads are required. For temperature measurements with the HT206B, the K-Type thermocouple is used.
- Insert the red test lead into the "VΩmA" or "+" input jack.
- Insert the black test lead into the "COM" or "-" input jack.
- For HT206B temperature measurement, connect the K-Type thermocouple to the designated temperature input ports, observing polarity.
5. Operating Instructions
5.1 General Operation
- Tendeudza switch inotenderera kune basa rekuyera raunoda.
- Connect the test leads or clamp the conductor as appropriate for the measurement.
- Read the measurement value on the LCD display.
- To turn off the device, rotate the switch to the "OFF" position. The HT206B also features automatic shutdown after 15 minutes of inactivity.
5.2 KAIWEETS HT206B Specific Operations
- AC Chiyero Chazvino: Rotate the switch to the AC Current range (e.g., 6/60A or 600A). Open the clamp jaw and enclose only the live wire of the circuit. Ensure the jaw is fully closed.
- FUNC. Button: Press the "FUNC." button to switch between secondary functions within a range, such as AC and DC voltage, or different frequency/duty cycle modes.
- NCV (Asingabatike Voltage) Kuwanikwa: Rotate the switch to the NCV position. Bring the top of the clamp meter near the conductor. The meter will beep and the NCV indicator will light up if AC voltage inowanikwa.
- BATA Basa: Press the "MAX/MIN" button briefly to activate the data hold function, freezing the current reading on the display. Press again to release.
- Tembiricha Kuyera: Connect the K-Type thermocouple. Rotate the switch to the temperature function (°C/°F). Insert the thermocouple probe into the substance or area to be measured.

Figure 5: HT206B temperature measurement applications.
5.3 KAIWEETS KM100 Specific Operations
- Voltage Kuyera (AC/DC): Rotate the switch to the desired AC V or DC V range. Connect test leads in parallel to the circuit.
- DC Chiyero Chazvino: Rotate the switch to the DC A range. Connect test leads in series with the circuit. Caution: Do not attempt to measure AC current with the KM100.
- Resistance Chiyero: Rotate the switch to the Ω range. Connect test leads across the component to be measured. Ensure the circuit is de-energized.
- Continuity Test: Rotate the switch to the continuity/diode position. Connect test leads across the circuit or component. A continuous beep indicates continuity.

Figure 6: KM100 Continuity Test.

Figure 7: KM100 DC Voltage Kuyera.
6. Kuchengeta
6.1 Kuchenesa
Pukuta mita casing pamwe adamp jira uye nyoro detergent. Usashandise abrasives kana solvents. Ita shuwa kuti mita yaoma usati washandisa.
6.2 Kutsiviwa kwebhatiri
When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate readings. Refer to Section 4.1 for battery installation instructions.
6.3 Kuchengeta
When not in use for extended periods, remove the batteries to prevent leakage. Store the meters and accessories in their carrying cases in a cool, dry place, away from direct sunlight and extreme temperatures.

Figure 8: KM100 stored in its carrying case.
7. Kugadzirisa matambudziko
- Hapana Chiratidziro/Chiratidzo chisina kusimba: Tarisa huwandu hwebhatiri uye tsiva kana zvichidikanwa. Iva nechokwadi chekuti mabhatiri akaiswa ne polarity chaiyo.
- Kuverenga Kusina kururama:
- Ensure the rotary switch is set to the correct measurement function and range.
- Iva nechokwadi chekuti matipi ekuyedza akabatana zvakanaka uye haana kukuvara.
- Zveclamp meter, ensure the jaw is fully closed around a single conductor for current measurement.
- For resistance or continuity, ensure the circuit is de-energized.
- Meter Does Not Respond: Turn the meter off and then on again. If the issue persists, replace batteries.
8. Zvinotsanangurwa
8.1 KAIWEETS HT206B Clamp Meter
| Kuyera | Range | Kururama |
|---|---|---|
| AC Yazvino | 6A/60A/600A | ±(2.5%+5) |
| AC Voltage | 6V/60V/600V | ±(1.0%+5) |
| DC Voltage | 600mV/6V/60V/600V | ±(0.5%+5) |
| Resistance | 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ | ±(1.0%+5) |
| Capacitance | 10nF/100nF/1μF/10μF/100μF/1mF/10mF/100mF | ±(4.0%+5) |
| Kakawanda / Duty Cycle | 10Hz kusvika 10MHz | ±(1.0%+3) |
| Tembiricha | -4°F kusvika 1832°F (-20°C kusvika 1000°C) | ±(2.5%+5) |
| Display Counts | 6000 Counts | |
| Safety Rating | CAT III 600V, CE, RoHS, IEC 61010-1 | |
| Simba Source | 2 x AAA Mabhatiri | |
8.2 KAIWEETS KM100 Digital Multimeter
| Kuyera | Range | Kururama |
|---|---|---|
| AC Voltage | 20V/200V/600V | ±(1.0%+5) |
| DC Voltage | 200mV/2V/20V/200V/600V | ±(1.0%+5) |
| DC Nhasi | 20mA/200mA/10A | ±(1.5%+5) |
| Resistance | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ | ±(1.2%+5) |
| Safety Rating | CAT III 600V, CE, RoHS | |
| Simba Source | 2 x AAA Mabhatiri (akagara akaiswa) | |
9. Warranty uye Tsigiro
KAIWEETS products are designed and manufactured to high-quality standards. Both the HT206B and KM100 are CE and RoHS certified, indicating compliance with European safety, health, and environmental protection requirements.
For specific warranty information or technical support, please refer to the warranty card included with your product or contact KAIWEETS customer service directly through their official channels.