Nhanganyaya
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your IRIS USA 3-in-1 WOOZOO Portable Air Conditioner and Dehumidifier. Please read this manual thoroughly before using the appliance and retain it for future reference.
Safety Information
Gara uchitevera chenjedzo dzekuchengetedza paunenge uchishandisa midziyo yemagetsi kuderedza njodzi yemoto, kuvhunduka kwemagetsi, uye kukuvara kwevanhu.
- Ita shuwa kuti magetsi anoenderana nevoltage yakatsanangurwa pane rating label yeyuniti.
- Usashandise chikwata netambo yakakanganisika kana plug.
- Usavhare maburi emhepo.
- Keep children away from the appliance. Activate the child lock function for added safety.
- Do not insert fingers or foreign objects into the air outlet.
- Bvisa unit usati wachenesa kana kuita chero kugadzirisa.
- This unit is UL listed to meet U.S. safety standards.
Product Overview
Familiarize yourself with the components and features of your portable air conditioner.

Mufananidzo 1: The IRIS USA WOOZOO Portable Air Conditioner shown with its accompanying remote control. The unit is white with a black top panel and front grille, featuring wheels for easy mobility.

Mufananidzo 2: An illustration highlighting the powerful cooling capabilities of the unit, including 10,000 BTU AC cooling power, 3 adjustable fan speeds, and a dehumidifying capacity of 74 pints per day.

Mufananidzo 3: A diagram illustrating the detailed dimensions of the portable air conditioner, showing its height (30 inches), depth (16 inches), and width (12 inches). Key specifications like weight (55 lbs), wattage (1010W), cable length (71 inches), and temperature range (61°F - 86°F) are also displayed.

Mufananidzo 4: This image shows the full-function remote control with a digital display, allowing easy operation of the unit. Below, a close-up of the built-in casters demonstrates the unit's easy maneuverability.
Setup uye Installation
Proper installation is crucial for optimal performance. This unit includes a window kit for exhaust ventilation.
- Kuburitsa: Carefully remove the unit and all accessories from the packaging. Check for any damage.
- Positioning: Place the unit on a flat, stable surface. Ensure there is at least 20 cm (8 inches) of space around the unit for proper airflow. The unit is equipped with wheels for easy movement.
- Window Kit Installation:

Mufananidzo 5: This image illustrates the quick and easy installation process, showing the exhaust hose connected to the unit and extended through a window using the included window kit.
- Assemble the window sealing plate kit according to the instructions provided in the separate window kit manual.
- Connect the exhaust hose to the unit's exhaust outlet and extend it to the window kit.
- Ensure the hose is not kinked or bent sharply, as this can restrict airflow and reduce efficiency.
- Power Connection: Batanidza tambo yemagetsi mudura remagetsi rakadzika.
Operating Instruction
Your portable air conditioner offers multiple modes for customized comfort. All functions can be easily operated with the included remote control.
Control Panel uye Remote Control
The unit can be controlled via the top-mounted control panel or the remote control. The remote control features a digital display for easy viewing.
Operating Modes
- Kutonhodza Mode: Provides powerful cooling for rooms up to 450 square feet.
- Press the MODE button until the cooling indicator light is on.
- Adjust the desired temperature using the + or - buttons (range: 61°F / 16°C to 86°F / 30°C).
- Gadzirisa kumhanya kwe fan uchishandisa iyo FAN button (3 speeds available).
- Fan Mode: Inotenderera mhepo pasina kutonhora.
- Press the MODE button until the fan indicator light is on.
- Gadzirisa kumhanya kwe fan uchishandisa iyo FAN bhatani.
- Dehumidifier Mode: Inobvisa mwando wakawandisa kubva mumhepo.
- Press the MODE button until the dehumidifier indicator light is on.
- The unit will automatically exhaust condensate in most environments.
Mamwe Mabasa
- Nzira yekurara: Activates quiet operation and gradually adjusts temperature for comfortable sleep. Press the RARA bhatani.
- Basa renguva: Set the unit to turn on or off automatically within a 24-hour period. Press the TIMER bhatani uye kushandisa + or - kuseta nguva yaunoda.
- Mwana Lock: Prevents accidental changes to settings. Refer to the remote control instructions for activation.
- Oscillation: Both vertical and horizontal oscillation can be adjusted manually to direct airflow.
Maintenance
Kugara kugadziridza kunovimbisa hupenyu hurefu uye kugona kweinotakurika air conditioner yako.
Sefa Kuchenesa

Mufananidzo 6: This image shows the reusable air filter being cleaned under running water, emphasizing the ease of maintenance with simple soap and water.
The unit is equipped with a washable air filter that can be cleaned with simple soap and water. Clean the filter every two weeks or more frequently depending on usage and air quality.
- Bvisa unit kubva pamagetsi.
- Tsvaga wobvisa firita yemhepo kubva kumashure kana kurutivi rwechishandiso.
- Wash the filter under running water with a mild detergent.
- Shamba zvakanaka wosiya firita yacho yooma zvachose usati waiisa zvakare muchina wacho.
General Care
- Pukuta kunze kweyuniti nekanyoro, damp jira. Usashandise makemikari ane hasha kana abrasive cleaners.
- For long-term storage, drain any accumulated water, clean the filter, and store the unit in a dry place.
Kugadzirisa matambudziko
Tarisa kuchikamu chino kune zvinowanzoitika uye mhinduro dzadzo.
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Unit haibatike. | Hapana simba, tambo yemagetsi isina kuvharwa, circuit breaker yakagumburwa. | Tarisa kubatana kwemagetsi, dzorerazve circuit breaker. |
| Chikwata hachitonhodzi zvakanaka. | Air filter dirty, exhaust hose blocked/kinked, room too large, windows/doors open. | Clean air filter, check exhaust hose, ensure proper room size, close windows/doors. |
| Chikwata chine ruzha. | Chigadziko chisiri panzvimbo yakati sandara, chakavharika nefeni. | Place on a level surface, check for obstructions in fan area. |
| Kubuda kwemvura. | Drain plug not properly sealed, unit tilted. | Ensure drain plug is secure, place unit on a level surface. |
Zvinotsanangurwa
| Feature | Detail |
|---|---|
| Model | WOOZOO Portable Air Conditioner |
| ASIN | B096SHCS8J |
| Cooling Capacity | 10,000 BTU (ASHRAE) |
| Nzvimbo yekuvhara | Kusvika ku450 sq ft |
| Kubvisa humhu hunyanzvi | 74 pints / zuva |
| Temperature Range | 61°F (16°C) kusvika 86°F (30°C) |
| Fan Speeds | 3 |
| Kushandisa Simba | 1010 W |
| Voltage | 115 Volts |
| Noise Level | 30 dB |
| Zviyero (D x W x H) | 31.5D x 39.5W x 77H Centimeters (inenge 12.4D x 15.6W x 30.3H inches) |
| Kurema | 55 Pounds (approx. 24.9 kg) |
| Special Features | LED Temperature Display, Remote Controlled, Sleep Mode, Timer, Child Lock, Auto Drain Function |
Warranty uye Support
For warranty information or technical support, please refer to the warranty card included with your product or contact IRIS USA customer service. Keep your purchase receipt as proof of purchase.
For further assistance, visit the official IRIS USA websaiti kana kubata mutsara wavo wekutsigira vatengi.