Nhanganyaya
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Hitachi WT-P200Y Automatic Shallow Well Pump. Please read this manual thoroughly before using the product and keep it for future reference.
The Hitachi WT-P200Y is an inverter-controlled automatic shallow well pump designed for reliable water supply. It features an easy-to-use control panel for convenient operation.
Safety Information
Gara uchitevera matanho ekuchengetedza kuti usakuvara kana kukuvara kwechigadzirwa.
- Ensure the power supply matches the pump's requirements (Single Phase 100V, 50/60Hz).
- Do not operate the pump without water, as this can cause damage.
- All electrical connections must be performed by a qualified electrician in accordance with local codes.
- Chengetedza vana nevashandi vasina mvumo kure nepombi panguva yekushanda.
- Bvisa simba usati waita chero kugadzirisa kana kugadzirisa.
- Chengetedza pombi kubva pakutonhora kwechando.
Setup uye Installation
Proper installation is crucial for optimal performance and longevity of your pump.
- Kuburitsa: Bvisa pombi nokungwarira kubva mupakeji yayo. Tarisa kana paine kukuvara kwekutumira.
- Kuiswa: Install the pump on a stable, level surface in a well-ventilated area, protected from direct sunlight, rain, and freezing. Ensure adequate space for maintenance.
- Piping Connections:
- Connect the suction pipe (25mm, Rc1) to the pump's suction inlet. Ensure an airtight seal to prevent air leaks.
- Connect the discharge pipe (25mm, Rc1) to the pump's discharge outlet.
- Use appropriate fittings and sealants to prevent leaks.
- Priming: Before initial operation, the pump must be primed.
- Remove the priming plug (if applicable) or fill the pump casing with water until full.
- Replace the plug securely.
- Kubatanidza Magetsi: Connect the power cord to a grounded 100V, 50/60Hz power outlet. Ensure the circuit is protected by a suitable circuit breaker.
Mufananidzo 1: Diagram showing the Hitachi WT-P200Y pump's dimensions and performance curve. The diagram illustrates the pump's physical measurements, including discharge and suction outlets, and a graph detailing the relationship between total head (m) and discharge volume (L/min) under various operating pressures and suction heights. This helps in planning installation and understanding operational limits.
Operating Instruction
The WT-P200Y features an easy-to-use control panel for selecting operating modes.
- Kutanga kwekutanga:
- After ensuring proper installation and priming, plug in the pump.
- The pump will automatically start when water is demanded (e.g., opening a faucet) and stop when demand ceases.
- Selecting Operating Pressure Modes: The control panel allows selection of different pressure modes. Refer to the panel diagram for specific settings.
- Standard Mode: Provides balanced pressure for general household use.
- High Pressure Mode: For applications requiring stronger water pressure.
- Low Pressure Mode: For situations where reduced pressure is desired.
- Automatic Operation: The pump is designed for automatic operation. It will detect water demand and adjust its output accordingly, thanks to its inverter technology.
Mufananidzo 2: Image displaying the easy-to-use control panel of the Hitachi WT-P200Y pump. The panel allows users to select from various operating pressure modes (Standard, High, Low) to suit different water usage requirements. This image also highlights the wear-resistant elastic casintekinoroji ye g.
Maintenance
Kugadziriswa nguva dzose kunovimbisa kugara kwenguva refu uye kushanda zvakanaka kwepombi yako.
- Mwedzi Cheki:
- Inspect for any visible leaks around connections.
- Check for unusual noises or vibrations during operation.
- Kuongorora Kwegore:
- Clean any debris from the pump's exterior.
- Verify the condition of the power cord and plug.
- For internal component checks, it is recommended to contact a qualified service technician.
- Winterization (for cold climates):
- Drain all water from the pump and piping to prevent freezing damage.
- Chengeta pombi yacho munzvimbo inodziya, yakaoma kana zvichibvira, kana kuifukidza zvakanaka.
Mufananidzo 3: Yemukati view of the Hitachi WT-P200Y pump, highlighting the innovative Y-shaped impeller design and the wear-resistant elastic casing. This design contributes to the pump's high lift capability and durability, reducing wear from sand and debris in the water.
Kugadzirisa matambudziko
Tarisa kuchikamu chino kune zvinowanzoitika uye mhinduro dzadzo.
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Pombi haina kutanga. | No power supply; tripped circuit breaker; motor overload. | Check power connection; reset circuit breaker; allow motor to cool down. |
| Pump runs but no water is delivered. | Pump not primed; air leak in suction line; low water level in well; clogged suction filter. | Re-prime the pump; check all suction connections for leaks; verify well water level; clean suction filter. |
| Kudzvinyirira kwemvura yakaderera. | Partial clog in piping; incorrect pressure mode selected; worn impeller. | Check and clear piping; select higher pressure mode on control panel; contact service for impeller inspection. |
| Pombi inotenderera nguva zhinji. | Small leak in plumbing system; pressure switch malfunction. | Inspect plumbing for leaks; contact service for pressure switch check. |
Zvinotsanangurwa
| Feature | Detail |
|---|---|
| Model | WT-P200Y |
| Brand | Hitachi |
| Simba Source | Rudzi rwetambo yemagetsi |
| Voltage | 100 Volts (Single Phase) |
| Frequency | 50/60Hz |
| Rated Output | 200W |
| Wattage (Power Consumption) | 440 W |
| Zviyero zveChigadzirwa (L x W x H) | 35.6 x 37.6 x 49 cm |
| Product Weight | 14 kg |
| Max Flow Rate | 35 litita / miniti |
| Max Simudza Kureba | 12 mamita |
| Color | Gireyi |
| Included Accessories | Bhuku reMirayiridzo |
Mufananidzo 4: Mukuru mukuru view of the Hitachi WT-P200Y Automatic Shallow Well Pump. This image provides an overall visual reference of the product's design and appearance.
Warranty uye Support
Ichi chigadzirwa chinouya ne 1-year mugadziri waranti kubva pazuva rekutenga. Ndapota chengetedza humbowo hwako hwekutenga kwezvichemo zvewaranti.
For technical support, service, or warranty inquiries, please contact Hitachi Global Life Solutions customer service. Contact information can typically be found on the official Hitachi websaiti kana pamagwaro ekutenga kwako.
Note: Unauthorized repairs or modifications will void the warranty.