Elitech ECB-5080S

Bhuku rekushandisa reElitech ECB-5080S Electrical Control Box Temperature Control Panel

Model: ECB-5080S

1. Chigadzirwa Pamusoroview

The Elitech ECB-5080S is an advanced electrical control box designed for precise temperature management in various applications. It integrates an MTC-6000N controller to manage cooling, defrosting, and fan operations. This unit is suitable for systems requiring 3-phase 380V power and up to 15Hp capacity, offering comprehensive protection features for reliable operation.

Elitech ECB-5080S Electrical Control Box front view

Mufananidzo 1: Mberi view of the Elitech ECB-5080S Electrical Control Box, showing the control panel with two digital displays, indicator lights for Power, Comp, Defr, Fan, and Fault, and an ON/OFF switch.

2. Key Features

  • Remote Monitoring: Parameters can be viewed or set remotely via website and mobile application. Data and graph reports are available in real-time.
  • Dual Display: Shows temperature on both integrated temperature controllers. Multiple indicator lights display the operational status of each connected device.
  • Multi-Alarms: Provides alerts for temperature over-limit, over-range conditions, or sensor malfunctions.
  • Comprehensive Protection: Includes high-pressure, low-pressure, module, overload, phase sequence, phase loss, three-phase unbalance, and inverse time protection.
  • Kushanda Offers refrigeration, defrosting, and fan three-way output. Equipped with two storage temperature sensors and one defrosting temperature sensor.

3. Setup uye Kuiswa

Proper installation is crucial for the safe and efficient operation of the ECB-5080S control box. It is recommended that installation be performed by a qualified electrician.

  1. Kukwidza: Securely mount the control box in a suitable location, ensuring adequate ventilation and protection from environmental elements.
  2. Power Connection: Connect the 3-phase 380V power supply to the designated terminals. Verify correct phase sequence and voltage.
  3. Load Connections: Connect the refrigeration unit, defrosting heaters, and fan motors to their respective output terminals as per the wiring diagram (refer to the detailed wiring diagram provided with the product packaging).
  4. Kuisa sensor: Install the two storage temperature sensors and one defrosting temperature sensor in their appropriate locations within the controlled environment. Ensure sensors are correctly positioned for accurate readings.
  5. Grounding: Ensure the control box is properly grounded to prevent electrical hazards.
Elitech ECB-5080S Electrical Control Box angled view

Mufananidzo 2: Angled view of the Elitech ECB-5080S Electrical Control Box, highlighting the side ventilation and overall robust construction.

4. Operating Instructions

The ECB-5080S utilizes an MTC-6000N controller for its primary functions. Familiarize yourself with the controller's interface for optimal use.

  • Batidza/Kudzima: Use the main ON/OFF switch on the front panel to power the unit.
  • Kuratidza Tembiricha: The dual digital displays show current temperatures. Refer to the MTC-6000N controller manual for specific display interpretations.
  • Kuisa Parameters: Access the controller's menu to set desired temperature ranges, defrost cycles, fan operation modes, and alarm thresholds. Consult the MTC-6000N controller's dedicated manual for detailed parameter setting procedures.
  • Indicator Lights:
    • SIMBA: Zvinoratidza kuti mudziyo uri kugamuchira simba.
    • COMP: Indicates the compressor (cooling) is active.
    • DEFR: Indicates the defrost cycle is active.
    • FAN: Indicates the fan is operating.
    • MHOSVA: Illuminates when an error or alarm condition is detected. Refer to troubleshooting for details.
  • Remote Access: Utilize the Elitech website or mobile application for remote monitoring and parameter adjustments. Ensure the unit is connected to a network as per its network configuration guide.
Elitech ECB-5080S Electrical Control Box with ON/OFF switch

Mufananidzo 3: Pedyo-up view of the Elitech ECB-5080S control panel, emphasizing the ON/OFF switch and the two integrated temperature controllers.

5. Kuchengeta

Regular maintenance ensures the longevity and optimal performance of your ECB-5080S control box.

  • Kuchenesa: Periodically clean the exterior of the control box with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Kufefetedza Ensure that ventilation openings are clear of dust and obstructions to prevent overheating.
  • Connections: Annually inspect all electrical connections for tightness and signs of corrosion. Tighten any loose connections.
  • Kuongorora Sensor: Verify that temperature sensors are clean and securely mounted. Check sensor cables for damage.
  • Zvigadziriso zveSoftware: Check the Elitech website or app for any available firmware updates for the MTC-6000N controller to ensure optimal functionality and security.

6. Kugadzirisa matambudziko

This section provides solutions to common issues. For complex problems, contact Elitech technical support.

DambudzikoZvinogona KukonzeraSolution
Unit haibatike.No power supply; main switch off; faulty wiring.Check power source; ensure main switch is ON; inspect wiring connections.
Kuratidza tembiricha hakuna kururama.Faulty sensor; sensor incorrectly placed; wiring issue.Check sensor connections; verify sensor placement; replace faulty sensor if necessary.
FAULT indicator is lit.Over-limit temperature; sensor error; protection activated (e.g., phase loss).Check alarm messages on controller; inspect sensors; verify power supply and phase integrity.
Cooling/Defrost/Fan not operating.Incorrect parameter settings; faulty output relay; motor/component failure.Verify controller settings; check indicator lights; inspect connected components.

7. Zvinotsanangurwa

BrandElitech
Model NumberECB-5080S
Voltage380 Volts (3 Phase)
Maximum Horsepower15 Hp
Controller TypeMTC-6000N
MabasaRefrigeration, Defrosting, Fan Control
Dziviriro ZvimiroHigh/Low Pressure, Module, Overload, Phase Sequence/Loss, Three-phase Unbalance, Inverse Time
ASINB097MXGKFP
UPC781454242337

Related Documents - ECB-5080S

Preview Elitech Industrial Refrigeration uye Process Temperature Control Solutions
Elitech inopa huwandu hwakakwana hwetembiricha yekudzora mhinduro dzemaindasitiri firiji uye maitiro ekushandisa. Gwaro iri rinodonongodza akasiyana thermostats, magetsi ekudzora mapaneru, uye ese-chinangwa vadziviriri, achisimbisa maitiro avo, hunyanzvi hwekuita, uye mamiriro ekushandisa.
Preview Elitech MTC-2120S Temperature Controller User Manual
Chinyorwa chemushandisi cheElitech MTC-2120S, inogoneka imwe-sensor tembiricha inodzora ine firiji, defrost, uye over-tembiricha aramu mabasa. Inosanganisira tekinoroji paramita, mirairo yekushanda, madhayagiramu ewaya, uye kugadzirisa matambudziko.
Preview Mirayiridzo yekushanda kweMTC-5080 uye hunyanzvi hwekugadzira
Gwaro rakakwana reMTC-5080 digital temperature controller, rinotsanangura mabasa ayo, zvirevo, mashandiro ayo, uye nhungamiro dzekuchengetedza dzekuchengetedza tembiricha yekuchengetedza inotonhora.
Preview Elitech RCW-600WIFI IoT Temperature Monitor Mushandisi Manual
Chinyorwa chemushandisi cheElitech RCW-600WIFI, maviri-chiteshi IoT tembiricha yekutarisa ine WiFi yekubatanidza kune kure data. viewing, kutarisa, uye manejimendi mune zvekudya, catering, logistics, uye HACCP maindasitiri.
Preview Elitech Product Selection Guide: Refrigeration and Industrial Control Solutions
A comprehensive product selection guide from Elitech, featuring a wide range of refrigeration and industrial control equipment, including temperature controllers, data loggers, leak detectors, pressure transducers, and more. This guide provides detailed specifications, applications, and technical parameters for various Elitech products.
Preview Elitech STC-9200A Temperature Controller User Manual
Bhuku rekushandisa reElitech STC-9200A, chinodzora tembiricha chemhando yepamusoro. Gwaro iri rinopa ruzivo nezvechigadzirwa pamusoroview, operation, specifications, technical parameters, indicator status, button functions, parameter lists, safety rules, and control outputs.