GYS 059856

GYS 059856 Pendi Gobvu Gauge Bhuku reMushandisi

1. Nhanganyaya

This manual provides detailed instructions for the safe and effective use of the GYS 059856 Paint Thickness Gauge. This portable device is designed for quick and easy measurement of non-magnetic coatings (such as paint or film) on metallic surfaces. It is an essential tool for various applications including the processing industry, automotive repair, metal treatment, chemical industry, and goods inspection.

Ndapota verenga bhuku rino zvakakwana usati washandisa mudziyo uye chengeta kuti ugozoushandisa mune ramangwana.

2. Safety Information

3. Chigadzirwa Pamusoroview

The GYS 059856 Paint Thickness Gauge features a compact design with an LCD display and intuitive controls.

GYS 059856 Paint Thickness Gauge, front view showing display, MODE, UNIT, and ZERO buttons.

Mufananidzo 1: Mberi view of the GYS 059856 Paint Thickness Gauge. The device is yellow with a black LCD screen at the top. Below the screen are three black buttons: 'MODE' on the left, 'UNIT' on the right, and 'ZERO' with a power symbol in the center bottom.

3.1 Zvikamu Zvikuru

4. Setup

4.1 Kuiswa kwebhatiri

Locate the battery compartment on the back of the device. Insert the required batteries, ensuring correct polarity. Close the battery compartment securely.

4.2 Kubatidza/Kudzima

Dzvanya uye ubate iyo ZERO button to power on the device. To power off, press and hold the ZERO button again. The device also features an automatic shut-off function to conserve battery life.

5. Operating Instructions

The GYS 059856 offers three measurement modes and supports both metric and imperial units.

5.1 Kusarudza Zviyero zveKuyera

Press the UNIT button to toggle between metric (µm) and imperial (mils) units.

5.2 Measurement Modes

Press the MODE button to cycle through the following measurement modes:

5.3 Kutora Chiyero

  1. Ensure the surface to be measured is clean and free of debris.
  2. Select the desired measurement unit and mode.
  3. Place the measurement probe firmly and perpendicularly onto the coated metallic surface.
  4. Verenga ukobvu hwakaratidzwa paLCD screen.
  5. Lift the device from the surface to prepare for the next measurement (in Single mode).

6. Calibration

Accurate measurements depend on proper calibration. The device supports three calibration functions:

6.1 Zero Calibration

This calibration is performed on an uncoated, bare metallic surface to establish a zero reference point. Place the probe on a clean, uncoated metal surface and follow the on-screen instructions or refer to the device's specific calibration sequence (usually involving the ZERO bhatani).

6.2 Mapoinzi Maviri Calibration

This method uses two known thickness standards (e.g., a thin film and a thicker film) to calibrate the device across a range. This provides more accurate readings for varying thicknesses.

6.3 Easy Calibration

Refer to the device's specific instructions for "Easy Calibration," which may involve a simplified process for quick adjustments.

Note: Always calibrate the device before critical measurements or if you suspect inaccurate readings.

7. Kuchengeta

8. Kugadzirisa matambudziko

DambudzikoZvinogona KukonzeraSolution
Mudziyo haubatike.Mabhatiri akaderera kana kuti apera simba; polarity yebhatiri isiriyo.Replace batteries; check battery orientation.
Kurava kusina kururama.Device not calibrated; dirty probe; surface not clean; incorrect measurement mode.Perform calibration; clean probe and surface; select appropriate measurement mode.
Display shows "OL" or "Err".Chiyero chakapfuura; sensor kukanganisa.Ensure measurement is within device's range; restart device. If error persists, contact support.

9. Zvinotsanangurwa

10. Warranty uye Tsigiro

For warranty information and technical support, please refer to the official GYS website or contact your local distributor. Information regarding spare parts availability is not provided in the product specifications.

Mukuru weGYS Websaiti: www.gys.fr

Related Documents - 059856

Preview GYS POWERDUCTION 10R - Manuel d'utilisation et de sécurité
Manuel d'utilisation et de sécurité pour le GYS SIMBA 10R, un appareil de chauffage par induction conçu pour débloquer et retirer facilement les pièces mécaniques grippées. Idéal pour les secteurs mota, agricole, et de la construction métallique.
Preview GYS DRAW ALIGNER PRO User Manual and Instructions
Comprehensive user manual for the GYS DRAW ALIGNER PRO, covering safety instructions, assembly, application, maintenance, troubleshooting, technical specifications, and warranty information for professional sheet metal straightening.
Preview GYS GYSPOT ALU PRO FV - Manuel d'utilisation et de sécurité
Manuel d'utilisation et de sécurité pour le débosseleur GYS GYSPOT ALU PRO FV. Ce document fournit des instructions détaillées pour l'installation, l'utilisation, la maintenance et les précautions de sécurité brothers à cet appareil de réparation de carrosserie automobile en aluminium.
Preview GYS PROGYS 200 FV Käyttöopas: MMA ja TIG Hitsauskone
Tutustu GYS PROGYS 200 FV MMA- ja TIG-hitsauskoneen käyttöohjeeseen. Opi turvallinen käyttö, asennus ja huolto tästä monipuolisesta hitsauslaitteesta.
Preview GYS ELECTRO FORCE: Professional Car Body Straightening System | User Manual
Comprehensive user manual for the GYS ELECTRO FORCE straightening system. Learn about operation, safety, specifications, troubleshooting, and maintenance for professional automotive body repair.
Preview GYS Gyspot Inverter PTI 400V Spot Welder Manual
Comprehensive manual for the GYS Gyspot Inverter PTI 400V spot welder, covering assembly, operation, safety guidelines, maintenance, and technical specifications for automotive body repair.