SMACO Heap-01

SMACO PCP Air Compressor (Model Heap-01) User Manual

Brand: SMACO

Muenzaniso: Heap-01

1. Ruzivo Rwakakosha Chekuchengetedza

Please read this manual thoroughly before operating the SMACO PCP Air Compressor. Failure to follow these instructions may result in serious injury or property damage. Keep this manual for future reference.

2. Chigadzirwa Pamusoroview

2.1 Mamiriro Akakosha

2.2 Zvikamu uye Zvinodzora

Familiarize yourself with the main components of your SMACO PCP Air Compressor.

SMACO PCP Air Compressor with included accessories like wrenches, O-rings, and filters.

Figure 1: SMACO PCP Air Compressor and Accessories. This image displays the SMACO PCP Air Compressor unit along with its various accessories, including connection hoses, power cables, spare O-rings, and tools for maintenance.

Diagram highlighting key features of the SMACO PCP Air Compressor, including adjustable voltage, pressure gauge, oil moisture filter, wire spool design, pressure valve, power switch, and safety valve.

Figure 2: Compressor Features Diagram. An illustrative diagram pointing out the main functional parts of the compressor, such as the adjustable voltage switch, pressure gauge, built-in oil moisture filter, wire spool design for cables, pressure valve, power switch, and safety valve.

3. Setup Guide

3.1 Kuburitsa uye Kuongorora

  1. Nyatsobvisa zvese zvikamu kubva pakurongedza.
  2. Inspect the compressor and accessories for any signs of damage during shipping. Contact customer support if any damage is found.
  3. Ensure all listed accessories are present.

3.2 Kutanga Kubatanidza

Before operating, ensure proper connections for power and inflation.

Pedyo-up views of the adjustable pressure gauge, pressure relief valve, and safety valve on the SMACO PCP Air Compressor.

Figure 3: Adjustable Gauge, Pressure Relief, and Safety Valve. Detailed images showing the adjustable pressure gauge for setting desired pressure, the pressure relief valve that automatically exhausts air when peak pressure is reached, and the safety valve with an explosion-proof disc.

  1. Connect the Inflation Hose: Securely attach the inflation hose to the compressor's output port and to the tank you intend to fill. Ensure a tight seal to prevent leaks.
  2. Sarudza Power Source:
    • For AC Power (110V-220V): Plug the AC power cord into the compressor's AC input and then into a grounded wall outlet. The initial setting is typically for 110V AC.
    • For DC Power (12V Car Battery): Batanidza tsvuku clamp to the positive (+) terminal of your car battery and the black clamp to the negative (-) terminal. Ensure your car engine is running to provide stable power and prevent battery drain.
SMACO PCP Air Compressor powered by a 12V car battery outdoors and by 110V/220V AC home power indoors.

Figure 4: Dual Power Options. This image demonstrates the dual power capability of the compressor, showing it connected to a car battery for outdoor use and plugged into a standard AC outlet for indoor operation.

4. Operating Instructions

4.1 Pre-Operation Chekilist

4.2 Inflation process

  1. Sarudza Power Mode: Set the power switch to 'I' for DC (12V) or 'II' for AC (110V-220V).
  2. Set Target Pressure: Rotate the pressure setting knob on the gauge to your desired inflation pressure. The machine will automatically stop when this pressure is reached.
  3. Start Compressor: Press the 'START' button. The compressor will begin to operate, and the cooling fans will activate.
  4. Tarisa mafambiro Observe the real-time pressure on the gauge. Although auto-shutoff is present, it is good practice to monitor the process.
  5. Otomatiki Shutoff: The compressor will automatically stop filling when the preset pressure is achieved. The cooling fan will continue to run to dissipate heat.
  6. Manual Stop: To stop the compressor manually at any time, press the 'OFF' button.
  7. Release Pressure: After inflation is complete and the compressor has stopped, slowly open the bleed valve to release any residual pressure in the hose before disconnecting.
  8. Dimbura: Once pressure is fully released, disconnect the inflation hose from the tank and the compressor. Then, disconnect the power source.

4.3 Cooling Cycle

The compressor is designed with a duty cycle to prevent overheating. For optimal performance and longevity:

Diagram illustrating the fan cooling system of the SMACO PCP Air Compressor, emphasizing its oil-free, fan-cooled, oil-moisture filtered, and durable design.

Figure 5: Fan Cooling System. A visual representation of the compressor's internal fan cooling system, highlighting its oil-free operation, active cooling fans, integrated oil-moisture filter, and overall durable construction. A note indicates a 25-minute run / 10-minute cool-down duty cycle.

5. Kuchengeta

Regular maintenance ensures the longevity and reliable operation of your compressor.

5.1 Oil-Moisture Filter

5.2 General Care uye Kuchengeta

6. Kugadzirisa matambudziko

If you encounter issues with your SMACO PCP Air Compressor, refer to the following common problems and solutions:

DambudzikoZvinogona KukonzeraSolution
Compressor haina kutanga.No power, incorrect power mode selected, power switch off.Check power connections, ensure power source is active (e.g., car engine running for DC), select correct power mode (I for DC, II for AC), press 'START'.
Compressor runs but does not inflate or inflates slowly.Bleed valve open, loose hose connections, clogged filter, tank already full.Close bleed valve, tighten all hose connections, check and replace filter elements, verify tank pressure.
Compressor overheats and shuts down prematurely.Exceeded duty cycle, poor ventilation.Allow compressor to cool down for 10-15 minutes. Ensure operation in a well-ventilated area. Do not exceed 25 minutes of continuous operation.
Mhepo inodonha kubva pakubatanidza.Loose connections, worn O-rings.Tighten connections. Replace O-rings if they appear worn or damaged.
Safety valve activates.Pressure exceeded maximum limit.Immediately stop the compressor. Check the pressure gauge and ensure the target pressure is set correctly and does not exceed 4500 PSI. If the safety disc is blown, it must be replaced.

If the problem persists after attempting these solutions, please contact SMACO customer support.

7. Zvinyorwa zveUnyanzvi

TsanangudzoValue
BrandSMACO
Model NameHeap-01
Maximum Operating Pressure4500 PSI / 30 MPa / 300 Bar
Simba Source12V DC or 110V-220V AC
Voltage110 Volts (AC)
Maximum Power250 Watts
Kuyerera Kwemhepo Kugona11 litres paminiti
Noise Level65 Decibel
Item Weight21.4 Pondo
Product Dimensions9.5"L x 5.6"W x 10"H
Inoenderana Hose Diameter8 mamirimita
Special FeatureAutomatic Shut-Off
MaterialIron
ColorNhema

Ongorora: Magadzirirwo anogona kuchinja pasina ziviso.

8. Warranty uye Customer Support

SMACO products are manufactured to high-quality standards. For information regarding warranty coverage, please refer to the warranty card included with your purchase or visit the official SMACO website.

If you have any questions, require technical assistance, or need to report an issue, please contact SMACO customer support through the retailer where you purchased the product or via the contact information provided on the official SMACO website.

Related Documents - Heap-01

Preview SMACO S300 Plus Inotakurika Scuba Mushandisi Manual
Chinyorwa chemushandisi cheiyo SMACO S300 Plus inotakurika scuba mudziyo, inovhara chigadzirwa sumo, chimiro, mashandiro, kugadzirisa matambudziko, kuchengetedza, kugadzirisa, uye kudzivirira.
Preview SMACO S400 PRO Inotakurika Scuba Mushandisi Chinyorwa: Yakachengeteka Diving Guide
Yakazara mushandisi bhuku reSMACO S400 PRO inotakurika scuba mudziyo. Dzidza nezve maficha echigadzirwa, mashandiro, kuchengetedzwa, kugadzirisa matambudziko, uye kuchengetedza yako yepasi pemvura ruzivo.
Preview SMACO S700 Inotakurika Scuba Mushandisi Manual
Yakakwana mushandisi bhuku reSMACO S700 inotakurika scuba mudziyo, inovhara chigadzirwa sumo, chimiro, mashandiro, kugadzirisa matambudziko, uye kuchengetedzwa kwekuchengetedza yekunakidzwa diving uye kushandiswa kwekukurumidzira.
Preview SMACO S400 Inotakurika Scuba Mushandisi Chinyorwa: Operation, Chengetedza & Maintenance Guide
Yakakwana mushandisi bhuku reSMACO S400 Inotakurika Scuba. Dzidza nezvezvinhu zvechigadzirwa, mashandiro, kubatanidza, kukwira kwemitengo, kugadzirisa matambudziko, kuchengetedza, kugadzirisa, uye kuchengetedzwa kwekuchengetedza pakudhivha nekunakidzwa uye kushandiswa kwechimbichimbi.